RG-S2600G-I Series Switch Hardware Installation and Reference Guide
the source and the sensitive component, along which cable the interference conducts from one unit to another. Conducted
interference often affects the power supply of the equipment, but can be controlled by a filter. Radiated interference may
affect any signal path in the equipment and is difficult to shield.
1. Effective measures should be taken for the power system to prevent the interference from the electric grid.
2. The working ground of the switch should be preferably separated and kept as far as possible from the grounding
device of the power equipment or the anti-lightning grounding device.
3. Keep the equipment away from high-power radio transmitter, radar transmitting station, and high-frequency
large-current device.
4. Measures must be taken to shield static electricity.
Precaution for Fiber Connections
Before you connect the fibers, check that the optical connector type and fiber type match the optical interface type used. In
addition, pay attention to the Tx and Rx directions of the fiber. The Tx end of this equipment should be connected to the
Rx end of the peer equipment, and the Rx end of this equipment to the Tx end of the peer equipment.
Requirements of Installation Tools
Table 2-4 List of installation tools
Common tools
Cross screwdriver, straight screwdriver, related electric cables and optical cables, bolts, diagonal
pliers, straps
Special tools
Anti-static tools
Meters
Multimeter
The RG-S2600G-I series are not provided with a tool kit. Please prepare tools on your own.