RG-S2600G-I Series Switch Hardware Installation and Reference Guide
AC
input:
Rated voltage range: 100-240 V
Maximum voltage range: 90-264 V
Frequency: 50/60 Hz
Rated current: 0.5 A
Power cord specification: 10 A power cord
HVDC
input:
Input voltage range: 192 to 290 VDC
Input current range: 0.15 to 0.07 A
Heat Dissipation
The RG-S2628G-I is designed with no fans. To ensure good dissipation, sufficient ventilation space(10 cm distance from
both sides and the back panel of the chassis) should be reserved to avoid the air intake of the chassis from being blocked;
otherwise, the dissipation might be affected. Dust the device every three months to avoid blocking the ventilation
openings.
LED Indicators
Indicator
Faceplate
Marker
Status
Indication
Off
The switch is not powered on.
Blinking green
The switch is being initialized. If the blinking
persists, however, it indicates that an
abnormality occurs.
Solid green
The switch is in normal operation.
Solid yellow
It indicates a warning on the switch temperature.
Check the working environment of the switch
immediately.
Status indicator
Status
Solid red
Indicates a fault on the switch. For details, refer
to Section 5.2 Troubleshooting Common Faults.
Off
The port is not connected to a link.
Solid green
The link that the port connects to is Up.
RJ-45 port indicator
1~26
Blinking green
Data are being transceived at the port.
Off
The port is not connected to a link.
Solid green
The link that the port connects to is Up.
SFP port indicator
27F, 28F
Blinking green
Data are being tranceived at the port.
RG-S2652G-I
Technical specifications