13
speed / flow.
3.2.5 Rationing Mode
In rationing mode, the machine has been through the normal calibration process by default.
(1) On the main menu, select "Rationing" and press "Edit" to enter the rationing editing interface.
On the main menu, select " Rationing " and press "Enter" to enter rationing standby interface.
(2) On the rationing editing interface, input the required liquid volume and time, and press "Enter"
to save, and automatically jump to the standby interface.
(3) On the Rationing standby interface, press "ON/OFF" to realize a rationing process
3.2.6 Booking Mode
In booking mode, the machine has been through the normal calibration process by default.
Realize the function of “waiting-running 1-interval-running 2-interval-... running n”. You can
set the value of N (N = 0000 for infinite loop, the maximum can be set to 9999) and you can also set
the corresponding liquid volume and corresponding running time (related to the speed and calibration
ratio).
Booking
Mode
Action
Result
Waiting
Press ON/OFF” End the booking process and start running 0001# directly.
Press “HOME”
Exit the booking process and return to the main menu.
Running
Press ON/OFF”
End the running time and enter the suspension. If it is the last run, the
pump will automatically end the booking process.
Interval
Press ON/OFF” End this interval and enter the suspension.
Suspension
Press ON/OFF” Enter the next running process.
Press “HOME”
Exit the booking process and return to the main menu.
Table 3-2-6
List of function keys “ON/OFF" and "HOME" during the booking process