IO events
settings are located in the bottom right corner on the main view and are
accessible by clicking “Options” button (Fig. 2.3.6). IO is a specific property, which can be
measured by FM-Xxx3 device and sent to server. IO event is reaction to measured value. When IO
event occurs, device makes a record into its memory with measured values, date, time and location.
IO events can initiate GPRS session. Also IO can change device operation (by switching profile).
You can select up to 40 IO events, from which 20 can be CAN IO events.
To add IO to data record and create IO event(Fig 2.3.7):
1. Select space for IO. If it is “Disabled” then it is empty and new IO will be added, otherwise you
will overwrite IO and it will be replaced with new one.
2.Check “Enable”.
3.Select property ID you want to measure.
4.Set “Level” (optional, used for Hysteresis (explained below), IO dependant).
5.Set “Delta” (optional, used for Hysteresis (explained below), IO dependant).