Installation
Gas adjustment
Before any adjustment is started the gas and electricity supply to the appliance
must be turned off.
Change the injector of the burners
•
Remove the pan support, burner cover and flame spreader
•
Unscrew the injector using a spanner and replace it with the stipulated injector
for the new gas supply.
•
Carefully reassemble all of the components.
•
After the injectors are replaced, you must ensure the replacement injectors
are fully tightened.
Adjustment of the minimum flame level
•
Turn the taps down to the minimum level
•
Remove the dial from the tap and place a small bladed screw driver in the
centre of the tap shaft
•
The correct adjustment is obtained when the flame has a length of 3mm - 4mm
(for butane/propane gas the adjustment screw must be tightly screwed in).
12
Injector