DMS-3.1 Test Procedure
31
of
64
23. Once you see the “Upgrade Status” message appear as below then
All BridgeCo modules have firmware installed properly.
Confirm each BridgeCo module has the correct MAC ID installed.
There is a sticker on the module. Compare it to the MAC ID in this window.
Record and check that no MAC ID has been duplicated.
24. Record the MAC ID of each module in Step 6 and place in a spreadsheet.
Confirm the Img Version, Cne Version, and BSL Version are current versions,
The Current Versions are supplied by Russound SQA, check with them.
===============================================
======================
=
=
= UPGRADE STATUS
=
=
===============================================
======================
Module 1
Img Version : 20110207
CNE Version : 20110207
BSL Version : 20100927
MAC Address : 00:07:F5:2E:EA:34
Module 2
Img Version : 20110207
CNE Version : 20110207
BSL Version : 20100927
MAC Address : 00:07:F5:2E:EA:36
Module 3
Img Version : 20110207
CNE Version : 20110207
BSL Version : 20100927
MAC Address : 00:07:F5:2E:EB:18
root@dms31-0021c7040003:~#