background image

2. INTRODUCTION

Congratulations on your recent purchase of the Russound DPA-6.12 12-channel amplifier. The DPA-6.12 high-
current, high-quality amplifier is the heart of the home theater or multi-zone system. The DPA-6.12 12-channel
amplifier is capable of amplifying six stereo line level sources (CD players, tape decks, preamplifiers, tuners, etc.)
simultaneously in multi-zone, multi-source installations. The twelve amplifiers are arranged in pairs to provide six
stereo amplifiers. With separate gain controls for each channel, sound levels can be preset to accommodate most
rooms. The Main Bus Input allows for two or more stereo amplifiers to share the same audio source. With the
stereo/mono selector in the mono position, two amplifiers can serve as mono outputs. In the mono position the
six stereo pairs can be bridged to three stereo pairs for higher output power. The DPA-6.12 power output is 50
watts per channel into 8 ohms, and 75 watts into 4-ohms. Bridged adjacent outputs provide 100 watts of power
into 8-ohms and 150 watts of power into 4-ohms. All this power is backed by two high output toroidal transform-
ers. Each amplifier output channel incorporates thermal, short circuit protection and Russound’s unique Dynamic
Clipping Sensor that allows for better headroom and volume without clipping or distortion that is normally heard
in most amplifiers.

The Russound DPA-6.12 amplifier is built with pride. Fidelity, reliability and quality are the primary objective.
Russound products are guaranteed to provide years of enjoyment. 

3. POSSIBLE SYSTEM CONFIGURATIONS

The DPA-6.12 can be configured as an audio distribution system, or used as the main amplifier for a home the-
ater system. As an audio distribution amplifier each zone can independently drive several different sources by
using each of the individual line audio inputs for each of the zones. As a home theater amplifier the DPA-6.12
output can be bridged to provide high power out for the front channel while the remaining channels are used to
drive the surround effects.  

3

M

AIN

 B

US

I

NPUT

M

AIN

 B

US

O

UTPUT

BUS

BUS

BUS

BUS

BUS

BUS

LINE

LINE

LINE

LINE

LINE

LINE

STEREO

STEREO

STEREO

STEREO

STEREO

STEREO

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

BRGD

MONO

BRGD

MONO

BRGD

MONO

BRGD

MONO

BRGD

MONO

BRGD

MONO

DPA-6.12

NEWMARKET, NH USA

R

L

R

L

L

L

L

L

L

L

L

L

L

L

L

L

R

R

R

R

R

R

R

R

R

R

R

R

R

+

R

+

R

+

R

+

R

+

R

+

R

R

R

R

R

R

L–

L–

L–

L–

L–

L–

L+

L+

L+

L+

L+

L+

R

+

R

+

R

+

R

+

R

+

R

+

R

R

R

R

R

R

L–

L–

L–

L–

L–

L–

L+

L+

L+

L+

L+

L+

L

INE 

I

NPUT

L

INE 

I

NPUT

L

INE 

I

NPUT

L

INE 

I

NPUT

L

INE 

I

NPUT

L

INE 

I

NPUT

+12V

TRIGGER

+12V

TRIGGER

+12V

TRIGGER

+12V

TRIGGER

+12V

TRIGGER

+12V

TRIGGER

IN

IN

IN

IN

IN

IN

1

1

1

1

1

1

2

2

2

2

2

2

3

3

3

3

3

3

4

4

4

4

4

4

S

PEAKERS 

A

S

PEAKERS 

A

S

PEAKERS 

A

S

PEAKERS 

A

S

PEAKERS 

A

S

PEAKERS 

A

S

PEAKERS 

B

S

PEAKERS 

B

S

PEAKERS 

B

S

PEAKERS 

B

S

PEAKERS 

B

S

PEAKERS 

B

MUTING

DELAY TIME

MUTING

DELAY TIME

MUTING

DELAY TIME

MUTING

DELAY TIME

MUTING

DELAY TIME

MUTING

DELAY TIME

MINIMUM LOAD IMPEDANCE:

  8 OHM PER CHANNEL WHEN BOTH SPEAKER A AND B OUTPUTS ARE USED

  4 OHM PER CHANNEL WHEN SPEAKER ONLY A OR B OUTPUT IS USED

* FOR BRIDGED OPERATION SEE MANUAL

~120VAC

~60Hz

12A

THIS UNIT MUST BE

EARTH GROUNDED

DESIGNED IN THE USA

MADE IN TAIWAN

W

ARNING

 : S

HOCK

 H

AZARD

 –

D

O

 N

OT

 O

PEN

A

VIS

 : R

ISQUE

 D

E

 C

HOC

E

LECTRIQUE

 – N

ES

 P

AS

 O

UVRIR.

S

ERIAL

 #

Russound

FOR HOME OR OFFICE USE

DPA-6.12

Tested to Comply

with FCC Standards

Conforms to 
UL 6500
Certified to 
CSA C22.2 No1-94

68835

019

OUT

OUT

OUT

OUT

OUT

OUT

100mA

100mA

100mA

100mA

100mA

100mA

*

*

*

*

*

*

I

NPUTS

T

UNER

CD

T

APE

V

ID

1

V

ID

2

DVD

1

4

3

2

I

NPUTS

O

UTPUT

 T

O

 Z

ONES

L

R

L

EFT

V

IDEO

R

IGHT

F

USE

10A

CMN

IR

O

UT

1

2

3

4

S

WITCHED

AC O

UTLETS

115V~ 60Hz

1A M

AX 

T

OTAL

U

NIT

 I

NTERFACE

 B

U

NIT

 I

NTERFACE

 A

AC T

O

 AP-48

8A M

AX

AC 115V~

60Hz 10A M

AX

V+ G D1 D2 V+ G D1 D2 V+ G D1 D2 V+ G D1 D2 V+ G S T

V+ G S T

V+ G S T

V+ G S T

PR-4Z

NEWMARKET, NH U.S.A.

W

ARNING

 : S

HOCK

 H

AZARD

 – D

O

 N

OT

 O

PEN

A

VIS

 : R

ISQUE

 D

E

 C

HOC 

E

LECTRIQUE

 – N

ES

 P

AS

 O

UVRIR.

S

ERIAL

 #

K

EYPAD

 

1

K

EYPAD

 

2

K

EYPAD

 

3

K

EYPAD

 

4

P

AGE

 

1

P

AGE

 

2

P

AGE

 

3

P

AGE

 4

Conforms to
UL 1492
Certified to
CSA C22.2 #1
68835

ZONE 1

ZONE 2

ZONE 3

ZONE 4

Summary of Contents for DPA-6.12

Page 1: ...DPA 6 12 Instruction Manual 12 Channel Amplifier 1 2 3 5 6 4 6 Z O N E 1 2 C H A N N E L A M P L I F I E R POWER DPA 6 12 ZONE ...

Page 2: ...Power Sources The appliance should be connected to a power sup ply only of the type described in the operating instructions or as marked on the appliance 11 Grounding or Polarization The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated 12 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on...

Page 3: ...e DPA 6 12 output can be bridged to provide high power out for the front channel while the remaining channels are used to drive the surround effects 3 MAIN BUS INPUT MAIN BUS OUTPUT BUS BUS BUS BUS BUS BUS LINE LINE LINE LINE LINE LINE STEREO STEREO STEREO STEREO STEREO STEREO GAIN GAIN GAIN GAIN GAIN GAIN BRGD MONO BRGD MONO BRGD MONO BRGD MONO BRGD MONO BRGD MONO DPA 6 12NEWMARKET NH USA R L R L...

Page 4: ...When there is no audio the zone will go into standby Bus Line Switch Selects the Line audio input or the Main bus input for each zone When the Bus is selected the zone will amplify the audio on the Main Bus input When line is selected the zone will amplify the audio at the line input for that zone Gain Controls Left and Right gain controls adjust independently the sound level for each channel When...

Page 5: ...nt this delay setting will automatically put the amplifiers into standby mode after the preset period of time Power Two heavy duty 500va toroidal transformers power the DPA 6 12 Each transformer has three taps to power 3 stereo zones totaling six taps for the six stereo outputs The voltage setting for the AC input is set at the factory for opera tion of either 110VAC 60Hz or 240VAC 50Hz Please ref...

Page 6: ...replace any defective parts and correct any defect in workmanship without charge for either parts or labor For this warranty to apply the unit must be installed and used according to its written instructions If service is necessary it must be performed by Russound The unit must be returned to Russound at the owners expense and with prior written permission Accidental damage and ship ping damage ar...

Page 7: ...5 Forbes Rd Newmarket NH 03857 USA 603 659 5170 Fax 603 659 5388 e mail tech russound com Come visit us at ...

Reviews: