22
Russound MCA-C5 User and Installation Manual
TRIGGER CONNECTIONS
Zone 12VDC Trigger Outputs
There are eight zone 12VDC Triggers which are located under the routed IR
outputs. The 3.5mm mini port provides 12VDC 100mA when the corresponding
zone is turned on and is disengaged when the zone is turned off. The trigger
can be used to engage any 12VDC trigger device or component that does not
exceed 100mA, such as the Russound R235LS amplifier. The connections for
the trigger outputs are made using a two-conductor cable with 3.5mm male
mini-plug ports at each end. The tip is positive (+) and sleeve is negative (-).
12V trigger cable
R235LS (two-channel amplifier)
Speaker cable
Speakers
RCA cable
MCA-C5 Controller
Typical Amplifier Connection
Summary of Contents for MCA-C5
Page 1: ......
Page 41: ...39 Russound MCA C5 User and Installation Manual Notes ...
Page 166: ...ZXP E5 Power Supply_RevC sch 1 Thu Dec 18 16 48 45 2008 C ...
Page 167: ...ZXP E5 Power Supply_RevC sch 2 Thu Dec 18 16 48 46 2008 ...
Page 168: ...ZXP E5 Power Supply_RevC sch 3 Thu Dec 18 16 48 46 2008 ...
Page 189: ......