7
Emergency control system
(Emergency Lowering)
7-4
RUTHMANN-Steiger
®
TB270
BA.GB.12-27409-05-07-FTA-jr
7.2
Failure of operating staff
The operating staff in the working cage is no longer in a position to carry
out the operational Steiger-movements. Emergency lowering by means of
emergency control. The Steiger-movements are selected by means of the
emergency control from switch box at Steiger-substructure.
Keep ignition switched-on.
Select control stan
d „Emergency Control“.
Open switch box (emergency control) at Steiger-substructure by means
of a key.
Move boom into basic position (
chapter 6.6 ).
Retract jacks (
chapter 6.6 ).
Switch off control stand „Emergency control“.
Lock switch box (emergency control).
Main switch onto position „OFF“.