VDR-100G2/G2S Operation User Manual
62
RUT-UM-02-002_Rev. 2.0
7.3
Corrective Maintenance
7.3.1
Alarm Code Descriptions
Listed below are the alarm codes that may appear on the OAU LCD display:
Alarm Code
Description
System Error
Communication with the Record Application has been lost
Video Error
Communication with the Video Module has been lost
Audio Error
Communication with the Audio Module has been lost
FRM Error
Communication with the Final Recording Medium has been lost
Power Fail
Loss of utility power
PCM Error
Communication has been lost with the Power Control Module
Remote Error
Communication has been lost with the Remote Storage Module
Serial Error
Communication has been lost with the NMEA Module
Mic Error
Communication has been lost with one of the microphones
Disk Error
Failure to secure a data set
GPS Error
Data is failing to record on TimeMuxID parameters entry
Table 7-1: Alarm Code Description
Pressing the “Mute” button acknowledges the alarm code and silences the alarm. The red alarm indicator
lamp will stay illuminated until all alarm conditions are cleared. If there is more than one alarm condition,
the OAU display will cycle through the current alarm messages.
SYSTEM ERROR
: Turn the ship breaker for the VDR/SVDR power OFF. Wait 2 hours and 15 minutes.
Turn the VDR/SVDR power breaker back on and see if this has cleared the error.
If error returns, get
service to find and repair the error.
VIDEO ERROR:
Open Data Processing Unit (DPU) (the VDR/SVDR’s main cabinet) and ensure that the
2 AMP DC breaker inside marked
Video/NMEA
is closed. Make sure the Ethernet cable plugged into the
VDR/SVDR’s computer port marked
Video/NMEA
is pressed all the way into this port. There should be a
solid green link light and a flashing yellow light associated with this port. Locate the video module and
ensure it’s red LED power lights are lit and that its Ethernet cable is securely inserted in the modules
Ethernet port.
If error returns, get service to find and repair the error.
AUDIO ERROR:
Open Data Processing Unit (DPU) (the VDR/SVDR’s main cabinet) and ensure that the
2 AMP DC breaker inside marked
Audio/Alarm
is closed. Make sure the Ethernet cable plugged into the
VDR/SVDR’s computer port marked
Audio
is pressed all the way into this port. There should be a solid
green link light and a flashing yellow light associated with this port. Locate the audio module and ensure
it’s red LED power lights are lit and that its Ethernet cable is securely inserted in the modules Ethernet
port.
If error returns, get service to find and repair the error.
FRM ERROR:
Open Data Processing Unit (DPU) (the VDR/SVDR’s main cabinet) and ensure that the 2
AMP DC breaker inside marked
FRM
is closed. Make sure the Ethernet cable plugged into the
VDR/SVDR’s computer port marked
FRM
is pressed all the way into this port. There should be a solid
green link light and a flashing yellow light associated with this port. If problem still exists; open the FRM 2-
AMP breaker by pressing its
Red Button
, wait 5-seconds and close this breaker by pressing its
Black and
White Button marked with the number 2
.
If error returns, get service to find and repair the error.
PCM ERROR:
Open Data Processing Unit (DPU) (the VDR/SVDR’s main cabinet) and ensure that the
two serial connectors on the back of the computer are still firmly in place. If problem persists turn the ship
breaker for the VDR/SVDR power OFF. Wait 2 hours and 15 minutes. Turn the VDR/SVDR power
breaker back on and see if this has cleared the error.
If error returns, get service to find and repair the
error.
Summary of Contents for VDR-100G2
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 6: ...This page is intentionally blank...
Page 36: ...VDR 100G2 G2S Operation User Manual 26 RUT UM 02 002_Rev 2 0 This page is intentionally blank...
Page 44: ...VDR 100G2 G2S Operation User Manual 34 RUT UM 02 002_Rev 2 0 This page is intentionally blank...
Page 50: ...VDR 100G2 G2S Operation User Manual 40 RUT UM 02 002_Rev 2 0 This page is intentionally blank...
Page 78: ...Inside back cover...