VDR-100G2/G2S Operation User Manual
11
RUT-UM-02-002_Rev. 2.0
1.1.7.1
Rutter FRM (RUT-02447) Fixed Capsule
Figure 1-11 – Rutter FRM (RUT-02447) Fixed Capsule
The Rutter FRM (RUT-02447) Fixed Capsule is the “Black Box” storage medium for ships is coloured
bright orange for ease of location in the event of an incident. It is designed to be mounted externally close
to the bridge - typically on the ´monkey island´ - and is fitted with an acoustic beacon to aid underwater
recovery by a Remotely Operated Vehicle or diver in the event of an incident.
The unit is designed to meet the requirements of the IEC Performance standard which are the same as
those enforced by the maritime and aerospace authorities.
The protected memory is stored in the retrievable capsule and is connected by a quick-release cable-
connector assembly to the deckmount.
The Rutter FRM (RUT-02447) Fixed Capsule has a release mechanism to facilitate underwater recovery
both by a diver or a ROV. Suitable handles are provided to ensure that the capsule may be retrieved
safely after release.
When the Rutter FRM (RUT-02447) Fixed Capsule has been damaged after an incident, e.g. the capsule
was exposed to fire or the ship has sunk, the manufacturer should be contacted to extract the data.
Alternatively, authorities may apply to the manufacturer for instructions on how to retrieve the recorded
data.
1.1.7.2
L3 HVR-01/02 and SVR-01/02 Fixed FRM/SFRM Capsules
The externally mounted L3 SVR-02 Fixed SFRM Capsule is certified to meet or exceed requirements for
the environmental qualification categories of IEC 60945, and the survivability requirements of IEC 61996-
2.
The L3 SVR-02 Fixed SFRM Capsule is designed specifically for the Simplified Voyage Data Recorder
(S-VDR) as required in MSC.163(78) and includes an expandable 2 GB of solid state memory with a
storage capacity of more than 12 hours of voyage data including radar, audio, and sensor.
The L3 HVR-02 Fixed FRM Capsule is certified to meet or exceed requirements for the environmental
qualification categories of IEC 60945, and the survivability requirements of IEC 61996. The Unit includes
The Rutter FRM (RUT-02447) Fixed Capsule
contains 4GB of solid-state storage memory,
intended to store ship parameters in real time. The
storage memory will continually store the last 12
hours (minimum) of received data. When the power
supply is removed, the Rutter FRM (RUT-02447)
Fixed Capsule will retain the data for more then 10
years.
The Rutter FRM (RUT-02447) Fixed Capsule is an
armoured stainless steel (A316) capsule,
connected to other system components via
independent power and Ethernet cables. Data
transfer to and from the capsule is via a 10/100
Base-T Ethernet connection using TCP/IP standard
protocol.
Summary of Contents for VDR-100G2
Page 2: ......
Page 4: ...This page is intentionally blank...
Page 6: ...This page is intentionally blank...
Page 36: ...VDR 100G2 G2S Operation User Manual 26 RUT UM 02 002_Rev 2 0 This page is intentionally blank...
Page 44: ...VDR 100G2 G2S Operation User Manual 34 RUT UM 02 002_Rev 2 0 This page is intentionally blank...
Page 50: ...VDR 100G2 G2S Operation User Manual 40 RUT UM 02 002_Rev 2 0 This page is intentionally blank...
Page 78: ...Inside back cover...