Performance Data @ AHRI Standard Conditions – Cooling (con’t.)
Ratings
Outdoor
Unit
Furnace
Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER
EER
Indoor CFM
[L/s]
AHRI#
RA1442BJ1
RW1T08A4821N
RCF4821MTA
40500 [11.9]
27500 [8.1]
13000 [3.8]
15.10
12.50
1125 [530.9]
8954488
RCF4821STA
40000 [11.7]
29000 [8.5]
11000 [3.2]
14.50
12.00
1225 [578.1]
8954526
RCF4824HTA
41500 [12.2]
29000 [8.5]
12500 [3.7]
15.10
12.50
1250 [589.9]
8954556
RCF4824STA
40000 [11.7]
29000 [8.5]
11000 [3.2]
14.50
12.00
1225 [578.1]
8954587
RA1448AJ1
RW1T06A3617NAA
RCF4821MTAM
46000 [13.5]
30500 [8.9]
15500 [4.5]
14.50
12.00
1250 [589.9]
8443849
RCF4821STAM
45000 [13.2]
31400 [9.2]
13600 [4.0]
14.50
12.00
1225 [578.1]
8443851
RA1448AJ1
RW1T08A4821NAA
RCF4821MTAM
46500 [13.6]
31500 [9.2]
15000 [4.4]
14.00
11.70
1325 [625.3]
8443850
RCF4821STAM
45000 [13.2]
31200 [9.1]
13800 [4.0]
14.50
12.00
1200 [566.3]
8443852
RCF4824HTAM
47000 [13.8]
32200 [9.4]
14800 [4.3]
14.50
12.00
1350 [637.1]
8443853
RCF4824STAM
45000 [13.2]
31200 [9.1]
13800 [4.0]
14.50
12.00
1200 [566.3]
8443855
RA1448AJ1
RW1T10A6024NAA
RCF4824HTAM
48000 [14.1]
35300 [10.3]
12700 [3.7]
14.50
12.00
1550 [731.5]
8443854
RCF4824STAM
46500 [13.6]
34600 [10.1]
11900 [3.5]
14.00
11.70
1500 [707.9]
8443856
RA1460AJ1
RW1T10A6024NAA
RCF6024HTAM
57500 [16.9]
40200 [11.8]
17300 [5.1]
14.00
11.70
1550 [731.5]
8443865
RCF6024STAM
57500 [16.9]
40200 [11.8]
17300 [5.1]
14.00
11.70
1550 [731.5]
8443866
[ ] Designates Metric Conversions
Performance Data
RA14 Series