Accessories/Weighted Sound Power/Thermostats
RA14 Series
Rely on Ruud.™
9
Accessories
Model No.
RA1418
RA1424
RA1430
RA1436
RA1442
RA1448
RA1460
Compressor crankcase heater*
44-17402-44
44-17402-44
44-17402-44
44-17402-44
44-17402-45
44-17402-45
44-17402-45
Low ambient control
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
Compressor sound cover
68-23427-26
68-23427-26
68-23427-26
68-23427-26
68-23427-25
68-23427-25
68-23427-25
Compressor hard start kit
SK-A1
SK-A1
SK-A1
SK-A1
SK-A1
SK-A1
SK-A1
Compressor time delay
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
Low pressure control
RXAC-A07
RXAC-A07
RXAC-A07
RXAC-A07
RXAC-A07
RXAC-A07
RXAC-A07
High pressure control
RXAB-A07
RXAB-A07
RXAB-A07
RXAB-A07
RXAB-A07
RXAB-A07
RXAB-A07
Liquid Line Solenoid
(24 VAC, 50/60 Hz)
Solenoid Valve
200RD2T3TVLC
200RD2T3TVLC
200RD2T3TVLC
200RD2T3TVLC
200RD2T3TVLC
200RD3T3TVLC
200RD3T3TVLC
Solenoid Coil
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
Liquid Line Solenoid
(120/240 VAC, 50/60 Hz)
Solenoid Valve
200RD2T3TVLC
200RD2T3TVLC
200RD2T3TVLC
200RD2T3TVLC
200RD2T3TVLC
200RD3T3TVLC
200RD3T3TVLC
Solenoid Coil
61-AMG120/240V
61-AMG120/240V
61-AMG120/240V
61-AMG120/240V
61-AMG120/240V
61-AMG120/240V
61-AMG120/240V
Achiever Top Cap w/Label
91-101123-21
91-101123-21
91-101123-21
91-101123-21
91-101123-21
91-101123-21
91-101123-21
*Crankcase Heater recommended with Low Ambient Kit.
Weighted Sound Power Level (dBA)
A-WEIGHTED SOUND POWER LEVEL (dBA)
Unit Size - Voltage, Series
Standard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125
250
500
1000
2000
4000
8000
RA1418A
76
51.4
59.6
65.2
65.9
64.3
58.5
53.7
RA1424A
75.2
49.4
60.4
64.3
64.2
63.4
58.9
53.8
RA1430A
74
48.8
57.5
63.5
64
61.9
56.1
51
RA1436A
76
52.2
61.3
65.4
65.3
62.4
57.3
53.1
RA1442B
73
51.5
54.7
63.5
63.3
59.4
54.9
48.4
RA1448A
75.8
52.3
59.1
66.7
65.7
62.4
59.3
55.9
RA1460A
75
53.4
59.1
65.9
66.9
62.8
58.7
54.3
* Photos are representative. Actual models may vary.
For detailed thermostat match-up information,
see specification sheet form number T22-001.
300-Series *
Deluxe
Programmable
400-Series *
Special Applications/
Programmable
500-Series *
Communicating/
Programmable
200-Series *
Programmable
Thermostats