Be  sure  to  read  and  understand  the  entire  Use  and  Care  Manual  before  attempting  to  install  or  operate  this  
water  heater.  It  may  save  you  time  and  money.  Pay  particular  attention  to  the  Safety  Instructions.  Failure  to  
follow  these  warnings  could  result  in  serious  bodily  injury  or  death.  Should  you  have  problems  understanding  
the  instructions  in  this  manual,  or  have  any  questions,  STOP,  and  get  help  from  a  qualified  service  technician,  
or  the  local  gas  utility.

IMPORTANT  SAFETY  INFORMATION.

READ  ALL  INSTRUCTIONS  BEFORE  USING.

3

Failure  to  install  and  properly  vent  the  water  heater  to  the  outdoors  as  outlined  in  the  
Venting  Section  of  the  Installation  Instructions  in  this  manual  can  result  in  unsafe  operation  
of  the  water  heater.  To  avoid  the  risk  of  fire,  explosion  or  asphyxiation  from  carbon  
monoxide,  never  operate  this  water  heater  unless  it  is  properly  vented  and  has  an  adequate  
air  supply  for  proper  operation.  

Be  sure  to  inspect  the  vent  outlet  for  proper  installation  at  initial  start-­up;;  and  at  least  
annually  thereafter.  Refer  to  the  Care  and  Cleaning  section  of  this  manual  for  more  
information  regarding  vent  system  inspection.

DANGER!

INSTALL  AND  PROPERLY  VENT  THE  WATER  HEATER...

Gasoline,  as  well  as  other  flammable  materials  and  liquids  (  which  include,  but  are  not  
limited  to  adhesives,  solvents,  paint  thinners  etc.),  and  the  vapors  they  produce  are  
extremely  dangerous.  DO  NOT  handle,  use  or  store  gasoline  or  other  flammable  or  
combustible  materials  anywhere  near  or  in  the  vicinity  of  a  water  heater  or  any  other  
appliance.  Be  sure  to  read  and  follow  the  labels  on  the  water  heater,  as  well  as  the  warnings  
printed  in  this  manual.  Failure  to  do  so  can  result  in  property  damage,  bodily  injury  or  
death.

WARNING!

D A N G E R

FLAMMABLES

Flammable Vapors

Water heater has a main

burner flame.

The main burner flame:

1.  which can come on

     at any time and

2.  will ignite flammable

     vapors.

Vapors:

1.  cannot be seen,

2.  are heavier than air,

3.  go a long way on the

     floor and

4.  can be carried from 

     other rooms to the 

     main burner flame by 

     air currents.

      Vapors from flammable

liquids will explode and

catch fire causing death or

severe burns.

Do not use or store flammable

products such as gasoline,

solvents or adhesives in the

same room or area near the

water heater.
Keep flammable products:

1.  far away from heater,

2.  in approved containers,

3.  tightly closed and

4.  out of children's reach.

Installation:
Do not install water heater
where flammable products will

be stored or used unless the
main burner flame is at least

18" above the floor.  This will 
reduce, but not eliminate, the 
risk of vapors being ignited 

by the main burner flame.

Read and follow water heater warnings and instructions.  If 

owners manual is missing, contact the retailer or manufacturer.

AP15318 tankless 10 30 09.indd   3

11/9/2009   3:17:33 PM

Summary of Contents for AP15318

Page 1: ...ce and troubleshooting of the water heater This manual also includes a parts list It is very important that all persons who are expected to install operate or adjust this water heater read the instruc...

Page 2: ...swers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service READ THIS MANUAL Your safety and the safety of others a...

Page 3: ...solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a wa...

Page 4: ...117 or USC2 117 remote control Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water heater is supplying genera...

Page 5: ...th great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look and smell for gas lea...

Page 6: ...pacity greater than 52 gallons or tankless style consult the local building jurisdiction code for acceptable bracing procedures Have the installer show you the location of the gas shut off valve and h...

Page 7: ...burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater should be installed verticall...

Page 8: ...tion of Important Safety Information California Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Use Car...

Page 9: ...anticipated snow level B Clearance to window or door that may be opened 6 inches 15 cm for appliances 10 000 Btuh 3 kW 12 inches 30 cm for appliances 10 000 Btuh 3kW and 100 000 Btuh 30kW 36 inches 9...

Page 10: ...le and pets Install outdoor water heater such that air inlet and flue outlet is above anticipated snow level 1 8 m If soffit vent is too close block off and install new vent at another location Inside...

Page 11: ...pressure of 40 psi 276 kPa is required to achieve maximum flow rate To maintain proper performance ensure sufficient water supply pressure The Required Water Pressure Min Operating Water Pressure 14...

Page 12: ...heater and the water shutoff valve see the top left diagram The following should be addressed in regards to the HOT WATER OUTLET Connections between the water heater and point s of use should be as s...

Page 13: ...line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge...

Page 14: ...ode In Canada the latest edition of CSA B149 1 Natural Gas and Propane installation code Manual Gas Supply Line Shutoff Manual Gas Appliance Shutoff Union Sediment Trap Cap Valve Supplied Leak Testing...

Page 15: ...comply with local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada Canadian Electrical Code CSA C22 1 Part 1 F PRIORITY POWER O...

Page 16: ...projections in the base plate fit into the housings in the remote control Fix the control to the base plate at the bottom of the remote control using the screw provided Proceed to Connecting the remo...

Page 17: ...IRECTSEULEMENT SW3 SW2 SW1 U 2 1 S 1 3 2 W W 12 3 4 I J H F W W 2 3 4 1 B R Y O W BR BK 1 2 3 4 5 6 7 8 R Y O W BR BK 1 2 3 4 5 6 7 8 C 9 R BR BK BK W BK W 1 2 3 4 Y W BK 1 2 3 K SV0 SV1 SV2 SV3 W BK...

Page 18: ...tdoor Models Discharge Line To Suitable Drain To Hot Water Faucet s Relief Valve Union Drain Valve 6 15 cm Air Gap Manual Gas Appliance Shut off supplied Flue Terminal Trap Manual Gas Supply Line Shut...

Page 19: ...storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover any damage or defect caused by installation attachment o...

Page 20: ...tight and free of leaks Water filter is clean and in place Materials used are as instructed in this manual Water pipes are insulated and protected from freezing C Gas Supply Gas type matches rating p...

Page 21: ...tric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait five 5 minutes to clear ou...

Page 22: ...ere is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section it is recommended that a qualified person or serviceman perform the work Operating the w...

Page 23: ...t water faucet is in the open position Notice The factory setting allows operating temperatures between 100 F 38 C and 120 F 49 C Temperatures of 85 F 29 C and up to140 F 60 C can be achieved with the...

Page 24: ...odically this may be due to a problem in the water system Contact the water supplier or your plumbing contractor on how to correct this DO NOT plug the relief valve outlet Rapid closing of faucets or...

Page 25: ...a brush Use only mild soapy water other cleaners may damage the surface of the water heater DO NOT remove any label including the rating plate while cleaning or servicing DO NOT splash water on the r...

Page 26: ...ng conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from installat...

Page 27: ...icable Check and replace if necessary Error code displayed on remote control See instructions for Error Code and if required contact a dealer for service Not enough water demand Increase water flow Wa...

Page 28: ...grounded Low inlet gas pressure due to improper sizing Wrong gas type Open the Gas shutoff valve fully Contact gas utility company Fill up LP Gas container or replace with a new cylinder of LP Gas Bl...

Page 29: ...f parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring gas piping burners vent connectors or other safety devices Refer repairs to qualified service personnel WARNING For y...

Page 30: ...f the remote control will begin to blink While the number is blinking push the UP arrow temperature adjustment button and the Down arrow temperature adjustment button at the same time The display of t...

Page 31: ...f the water heater is installed less than 3 280 feet 1 000m no action is required How to adjust the DIP switch on the PCB for high altitude installation Check the altitude above sea level where the wa...

Page 32: ...onal Service Department at the following address 1241 Carwood Court Montgomery AL 36117 Phone 1 800 432 8373 When contacting the manufacturer the following information will be requested a Model and se...

Reviews: