background image

Available in 48, 60, 75 and 100 Gallon Tall Gas Models

8-Year* Limited Tank and Parts Warranty with a Professional Installation.

With ProtectionPlus

the 8-Year Limited Tank Warranty Becomes 12 Years!

Ruud Water Heaters

• 101 Bell Road, Montgomery, Alabama 36117-4305 • www.ruud.com

P R I N T E D I N U . S . A

0 4 / 0 8 W P

F O R M N O . 1 0 1 R - 6 1 R e v. 6

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.

Professional

Heavy Duty

Gas Water Heaters now with the Guardian System

TM

SPECIFY LP GAS WHEN ORDERING.

Add “P” suffix to the model number: Example: RUG PRO75PF.

• 60 gallon models meet SCAQMD rule 1121.
• 75 gallon models meet SCAQMD rule 1146.2.
† Energy Factor for 75 gallon LP model.

Get

4 MORE YEARS

with ProtectionPlus

8

Y E A R

L I M I T E D

T A N K W A R R A N T Y

B E C O M E S

12

For more details, see form 101-7.

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

HT. TO

WATER

HT. TO

GAS INPUT IN

RECOVERY IN

FIRST HOUR

HT. TO

TANK

GAS

VENT

CONN.

SIDE

WATER

SHIP.

ENERGY

AVG. ANN.

GAL.

THOUS. BTU/HR.

G.P.H. 90° RISE

DEL. G.P.H.

VENT

HT.

DIAM.

CONN.

SIZE

CNTR.

T&P

CONN.

WT.

FACTOR

OPER. COSTS

CAP.

MODEL NUMBER

NAT.

LP

NAT.

LP

NAT.

LP

A

B

C

D

E

F

G

H

(LBS)

NAT.

NAT.

48

RUG PRO50-65F

65

48

65.7

48.5

98

88

62-1/2

58-1/2

21-3/4

14

4

11

51-3/4

3/4

180

0.58

$315

60

RUG PRO60F

50

50

50.5

50.5

107

107

62

58

23

13-1/4

4

8

48-1/2

3/4

180

0.56

$326

75

RUG PRO75F

75.1

65

75.8

67.7

141

109

64

60

26-1/4

14-3/4

4

11

53-1/4

1

320

0.53†

N/A

T
A
L
L

T
Y
P
E

Guardian System

• One-of-a-kind air/fuel shut-off device offers double

protection

• Maintenance free – no filter to clean
• Standard replacement parts

Environmentally Friendly Burner

• Low NOx design for low nitrous oxide emissions

Self-Cleaning

(48 & 60 gallon models only)

• EverKleen

patented system fights sediment build-up

• Reduces fuel costs
• Provides more hot water

Easy to Light

• No matches required

Energy Efficient

• More hot water at low operating cost

Longer Life

• Patented magnesium anode rod design incorporates

a special resistor that protects

the tank from corrosion

High Altitude Compliant

• 48, 60 and 75 gallon models are certified for

applications up to 7,700 feet above sea level.
100 gallon models, up to 2,000 feet above sea level.
Some models are certified up to 10,200 feet above
sea level. Check factory for listings

Plus…

• Brass drain valve and temperature and pressure relief

valve are included

• Side water connections for space heating applications

(48 & 75 gallon models only)

• Meets or exceeds National Appliance Energy

Conservation Act (NAECA) requirements

*See Residential Warranty Information Brochure

for complete warranty information.

Energy Factor and Average Annual Operating
Costs based on D.O.E. (Department of Energy)
test procedures. D.O.E. national average fuel
rate natural gas $1.218/therm; LP $1.87/gallon

.

®

100 GALLON MODELS DO NOT INCLUDE THE GUARDIAN SYSTEM.
SPECIFY LP GAS WHEN ORDERING.

Add “P” suffix to the model number: Example: RUG PRO100-75P.

*SCAQMD rule 1121 compliance model.

These units are designed to meet or exceed ANSI (American National
Standards Institute) requirements and have been tested according to
D.O.E. test procedures and meet or exceed the energy efficiency
requirements of NAECA, ASHRAE standard 90, ICC Code and all state
energy efficiency performance criteria for energy consuming appliances.

Before purchasing this appliance, read important energy cost and
efficiency information available from your supplier.

E

G

B

A

C

F

H

HOT

WATER

CONNECTION

H

COLD

WATER

CONNECTION

D

1/2"

3/4" N.P.T.

RELIEF

VALVE

OPENING

FLUE

ANODE ROD

SIDE TAPS
(48 & 75 GAL.
MODELS 
ONLY)

SIDE TAPS ON

48 & 75 GAL. MODELS ONLY

Ruud Guardian System Features…

Flame Arrestor Plate

A specially-designed flame
arrestor prevents ignition of
vapors outside the combustion
chamber.

Maintenance Free

Superior air filtration prevents the
flame arrestor from becoming
clogged by lint, dust and oil.

Exclusive Combustion
Shut-off System

Should a spill incident occur, the
Guardian System shuts off the gas
supply and the air supply preventing
a sustained vapor burn in the
combustion chamber.

100

RUG PRO100-75

75

69

75.8

69.7

135

135

68

64

26-1/4

14-3/4

4

11

58

1

350

0.48

$380

100

RUG PRO100-73N*

73

73.7

116

68

64

26-1/4

14-3/4

4

11

58

1

350

0.48

$380

TALL

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

HT. TO

WATER

HT. TO

GAS INPUT IN

RECOVERY IN

FIRST HOUR

HT. TO

TANK

GAS

VENT

CONN.

SIDE

WATER

SHIP.

ENERGY

AVG. ANN.

GAL.

THOUS. BTU/HR.

G.P.H. 90° RISE

DEL. G.P.H.

VENT

HT.

DIAM.

CONN.

SIZE

CNTR.

T&P

CONN.

WT.

FACTOR

OPER. COSTS

CAP.

MODEL NUMBER

NAT.

LP

NAT.

LP

NAT.

LP

A

B

C

D

E

F

G

H

(LBS)

NAT.

NAT.

T
Y
P
E

Reviews: