background image

Rely on Ruud.™

4

The RA16 is our 16 SEER air conditioner and is part of the Ruud
air conditioner product line that extends from 13 to 20 SEER.
This highly featured and reliable air conditioner is designed for
years of reliable, efficient operation when matched with Ruud
indoor aluminum evaporator coils and furnaces or air handler
units with aluminum evaporators.

Our unique composite base (

) reduces sound emission, elimi-

nates rattles, significantly reduces fasteners, eliminates corro-
sion and has integrated brass compressor attachment inserts
(

). Furthermore it has incorporated into the design, water

 management features, means for hand placement (

) for unit

maneuvering, screw trays (

) and inserts for lifting off unit

pad. (

)

Service Valves (

) are rigidly mounted in the composite base

with 3" between suction and discharge valves, 4" clearance
below service valves and a minimum of 5" above the service
valves, creating industry leading installation ease. The minimum
27 square-inches around the service valves allows ample room
to remove service valve schrader prior to brazing, plenty of
clearance for easy brazing of the suction and discharge lines to
service valve outlets, easy access and hookup of low loss refrig-
erant gauges (

), and access to the service valve caps for

opening. For applications with long-line lengths up to 250 feet
total equivalent length, up to 200 feet condenser above evapora-
tor, or up to 80 feet evaporator above condenser, the long-line
instructions in the installation manual should be followed.

Controls are accessed from the corner of the unit by removing
only two fasteners from the control access cover, revealing the
industry’s largest 15" wide and 14" tall control area (

). With all

this room in the control area the high voltage electrical whip (

)

can easily be inserted through the right size opening in the bot-
tom of the control area. Routing it leads directly to contractor
lugs for connection. The low voltage control wires (

) are easily

connected to units low voltage wiring. If contactor or capacitor
(

) needs to be replaced there is more than adequate space to

make the repair. Furthermore, if high pressure and low pressure
model was not purchased but is desired to be installed in the
field, the service window (

) can be removed by removing two

screws, to access the high and low side schrader fittings for easy
field installation. The entire corner can be removed providing
ultimate access to install the high and low pressure switch. (

)

If in the rare event, greater access is needed to internal compo-
nents, such as the compressor, the entire corner of the unit can
be removed along with the top cover assembly to have unprece-
dented access to interior of the unit (

). Extra wire length is

incorporated into each outdoor fan and compressor so top
cover and control panel can be positioned next to the unit. With
minimal effort the plug can be removed from the compressor
and the outdoor fan wires can be removed from the capacitor to
allow even more uncluttered access to the interior of the unit (

).

Outdoor coil heights range from as short as 27" to 48", aiding
access to the compressor. Disassembly to this degree and com-
plete reassembly only takes a first time service technician less
than 10 minutes. (

)

All units utilize strong formed louver panels which provide indus-
try leading coil protection. Louver removal for coil cleaning is
accomplished by removing one screw and lifting the panel out of
the composite base pan. (

) All RA16 units utilize single row

coils (

) making cleaning easy and complete, restoring the

performance of the air conditioner back to out of the box perfor-
mance levels year after year. 

The outdoor fan motor has sleeve bearings and is inherently
protected. The motor is totally enclosed for maximum protection
from weather, dust and corrosion. Access to the outdoor fan is
made by removing four fasteners from the fan grille. The outdoor
fan can be removed from the fan grille by removing 4 fasteners
in the rare case outdoor fan motor fails. 

Each cabinet has optimized composite (

) fan orifice assuring

efficient and quiet airflow. 

1

2

3

4

7

8

9

10

12

13

6

11

5

14

15

15

17

16

19

Introduction to RA16 Air Conditioner

1

4

6

4

3

5

2

8

11

9

10

13

12 

16

14

18

15

19

7

17

Features & Benefits
RA16 Series

Summary of Contents for RA16 Series

Page 1: ...sound Rust resistant screws confirmed through 1500 hour salt spray testing PlusOne Expanded Valve Space 3 4 5 service valve space provides a minimum working area of 27 square inches for easier access...

Page 2: ...lectrical Data 8 Accessories 9 Weighted Sound Power 9 Thermostats 9 Unit Dimensions 10 Clearances 11 Wiring Diagrams 12 Application Guidelines 12 Refrigerant Line Size Information 13 14 Performance Da...

Page 3: ...1NA Achiever Series 4 ton 16 SEER Single Stage Air Conditioner 208 230 1 60 RA1660AJ1NA Achiever Series 5 ton 16 SEER Single Stage Air Conditioner 208 230 1 60 RA1618AJ1NB Achiever Series 1 1 2 ton 16...

Page 4: ...acitor needs to be replaced there is more than adequate space to make the repair Furthermore if high pressure and low pressure model was not purchased but is desired to be installed in the field the s...

Page 5: ...n and continually go through receiving inspections Each component installed on a unit is scanned assuring correct component uti lization for a given unit capacity and voltage All condenser coils are l...

Page 6: ...28 kW 24 24 000 7 03 kW 30 30 000 8 79 kW 36 36 000 10 55 kW 42 42 000 12 31 kW 48 48 000 14 07 kW 60 60 000 17 58 kW A 1st Design J 1ph 208 230 60 C 3ph 208 230 60 D 3ph 460 60 1 Single stage 2 Two s...

Page 7: ...5 75 000 22 kW 100 100 000 29 kW 125 125 000 37 kW 150 150 000 44 kW 3 up to 3 ton 4 2 1 2 to 4 ton 5 3 1 2 up to 5 ton 14 14 17 17 5 21 21 24 24 5 M Multi D Down Z Down zero clearance down flow X Low...

Page 8: ...e Hz 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 Maximum overcurrent protection amps 20 20 30 35 40 40 50 Minimum circuit ampacity 12 14 18 23 25 25 34 C...

Page 9: ...RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Solenoid Coil 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V Achiever Top Cap w Label 91 101123 21 91 1011...

Page 10: ...3 75 857 33 75 857 27 375 695 36 25 921 36 25 921 RA1630 27 685 35 75 908 35 75 908 27 375 695 38 25 972 38 25 972 RA1636 31 787 35 75 908 35 75 908 31 375 797 38 25 972 38 25 972 RA1642 39 990 35 75...

Page 11: ...Service 24 609 6 Service 24 609 6 Service 18 457 2 WALL WALL WALL WALL NOTE NUMBERS IN mm CLEARANCES IMPORTANT When installing multiple units in an alcove roof well or partially enclosed area ensure t...

Page 12: ...G W R TYPICAL THERMOSTAT SUBBASE X TYPICAL ELECTRIC HEAT LOW VOLTAGE JUNCTION BOX Application Guidelines 1 Intended for outdoor installation with free air inlet and outlet Outdoor fan external static...

Page 13: ...3 36 3 8 9 53 1 4 6 35 25 7 62 N R N R N R N R N R N R N R N R N R N R N R 5 16 7 94 25 7 62 50 15 24 60 18 29 45 13 72 35 10 67 20 6 1 5 1 52 N R N R N R N R N R 3 8 9 53 25 7 62 50 15 24 75 22 86 80...

Page 14: ...88 0 99 0 97 0 95 0 94 0 93 0 93 0 91 0 91 0 9 0 89 0 87 0 86 3 4 19 05 1 00 0 99 0 99 0 98 0 98 0 97 0 96 0 96 0 95 0 95 0 94 0 94 7 8 22 23 1 00 1 00 0 99 1 00 0 99 0 99 0 99 0 98 0 98 0 98 0 97 0 9...

Page 15: ...0 7 0 17500 5 1 6500 1 9 14 00 12 20 800 377 6 7940713 RCF2421HTAM RXMD C04 24000 7 0 17500 5 1 6500 1 9 14 00 12 20 800 377 6 7940680 RA1630AJ1 RCF3621MTAM RXMD C04 29600 8 7 21000 6 2 8600 2 5 14 50...

Page 16: ...7 20500 6 0 9100 2 7 16 00 13 00 875 413 0 7940931 RCF3621STAM 28400 8 3 21100 6 2 7300 2 1 16 00 13 00 875 413 0 7940975 RA1630AJ1 R801TA075417MSA RCF3617STAM 29000 8 5 22100 6 5 6900 2 0 16 00 13 0...

Page 17: ...RCF3621MTAM 36000 10 6 25100 7 4 10900 3 2 16 00 13 00 1275 601 7 7941818 RCF3621STAM 35200 10 3 24700 7 2 10500 3 1 15 50 13 00 1000 471 9 7941862 RA1636AJ1 R801TA075521ZSA RCF3621MTAM 36000 10 6 25...

Page 18: ...3 00 1100 519 1 7942646 RA1648AC1 R801TA075317ZSA RCF4821STAM 43500 12 7 29500 8 6 14000 4 1 15 50 13 00 1225 578 1 7942895 RA1648AC1 R801TA075417MSA RCF4821STAM 43500 12 7 29200 8 6 14300 4 2 16 00 1...

Page 19: ...00 1425 672 5 7943799 RA1660AC1 R801TA125524MSA RCF6024HTAM 58000 17 0 41600 12 2 16400 4 8 15 50 13 00 1650 778 7 7943771 RCF6024STAM 58000 17 0 41600 12 2 16400 4 8 15 50 13 00 1650 778 7 7943800 RA...

Page 20: ...5 1 6500 1 9 15 50 13 00 850 401 2 7940682 RA1624AJ1 R802VA075317MSA RCF2417HTAM 24000 7 0 17500 5 1 6500 1 9 16 00 13 00 875 413 0 7940578 RCF2417MTAM 24000 7 0 17500 5 1 6500 1 9 16 00 13 00 875 41...

Page 21: ...3 24400 7 2 10600 3 1 15 50 13 00 975 460 1 7941432 RA1636AC1 R802VA075317ZSA RCF3617STAM 35200 10 3 24900 7 3 10300 3 0 15 10 12 50 1050 495 5 7941360 RCF3621MTAM 36000 10 6 25100 7 4 10900 3 2 16 00...

Page 22: ...1 7 27500 8 1 12500 3 7 15 50 13 00 1100 519 1 7942231 RA1642AC1 R802VA075421ZSA RCF4821STAM 41000 12 0 29600 8 7 11400 3 3 15 50 13 00 1300 613 5 7942232 RCF4824HTAM 42000 12 3 31100 9 1 10900 3 2 16...

Page 23: ...0400 8 9 13600 4 0 15 50 13 00 1300 613 5 7943228 RCF4824HTAM 46000 13 5 33000 9 7 13000 3 8 16 00 13 00 1450 684 3 7943264 RCF4824STAM 44000 12 9 30400 8 9 13600 4 0 15 50 13 00 1300 613 5 7943299 RA...

Page 24: ...50 13 00 1500 707 9 7943554 RCF6024STAM 57000 16 7 39400 11 5 17600 5 2 15 50 13 00 1500 707 9 7943583 RA1660AJ1 R802VA125524MSA RCF6024HTAM 57500 16 9 40100 11 8 17400 5 1 16 00 13 00 1525 719 7 794...

Page 25: ...17MSA RCF3617STAM 28400 8 3 21200 6 2 7200 2 1 16 00 13 00 925 436 6 7940910 RCF3621MTAM 29800 8 7 21000 6 2 8800 2 6 16 00 13 00 950 448 4 7940942 RCF3621STAM 28600 8 4 21500 6 3 7100 2 1 16 00 13 00...

Page 26: ...01521MSA RCF4821STAM 41000 12 0 30200 8 9 10800 3 2 15 10 12 50 1400 660 7 7942575 RCF4824HTAM 42000 12 3 31100 9 1 10900 3 2 15 50 13 00 1425 672 5 7942617 RCF4824STAM 41000 12 0 30200 8 9 10800 3 2...

Page 27: ...15 10 12 50 1425 672 5 7943809 RA1660AJ1 R95TA0851521MSA RCF6024HTAM 56500 16 6 38700 11 3 17800 5 2 15 10 12 50 1475 696 1 7943557 RCF6024STAM 56500 16 6 38700 11 3 17800 5 2 15 10 12 50 1475 696 1 7...

Page 28: ...5 1 6500 1 9 15 50 13 00 850 401 2 7940632 RCF2421MTAM 24000 7 0 17500 5 1 6500 1 9 15 50 13 00 775 365 8 7940691 RA1624AJ1 R96VA0702317MSA RCF2417HTAM 24000 7 0 17500 5 1 6500 1 9 16 00 13 00 775 36...

Page 29: ...00 7 4 10900 3 2 16 00 13 00 1250 589 9 7941481 RCF3624MTAM 36000 10 6 25100 7 4 10900 3 2 16 00 13 00 1250 589 9 7941515 RA1636AC1 R96VA1152524MSA RCF3624HTAM 36000 10 6 25100 7 4 10900 3 2 16 00 13...

Page 30: ...CF4824STAM 44000 12 9 30400 8 9 13600 4 0 15 50 13 00 1300 613 5 7942981 RA1648AC1 R96VA1002521MSA RCF4821STAM 44000 12 9 30700 9 0 13300 3 9 15 50 13 00 1350 637 1 7942909 RCF4824HTAM 46000 13 5 3310...

Page 31: ...1 7941769 RF1P3624STAN 36000 10 6 25100 7 4 10900 3 2 14 50 12 20 1100 519 1 7943763 RF1T3624MTAN 36000 10 6 25100 7 4 10900 3 2 16 00 13 00 1025 483 7 7941770 RBHP 21 36000 10 6 25100 7 4 10900 3 2 1...

Page 32: ...00 1500 707 9 7943534 RH1T4821STAN 45000 13 2 32000 9 4 13000 3 8 16 00 13 00 1400 660 7 7943535 RH1T4824STAN 45500 13 3 33500 9 8 12000 3 5 16 00 13 00 1550 731 5 7943536 RH2T4824MTAN 46500 13 6 331...

Page 33: ...10 6 25100 7 4 10900 3 2 16 00 13 00 1000 471 9 7941853 RCF3621STAM 35000 10 3 24400 7 2 10600 3 1 15 10 12 50 975 460 1 7941897 RA1642AC1 RHWB 04WMX36B RCF4821STAM 40500 11 9 28600 8 4 11900 3 5 15...

Page 34: ...ondenser fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts wi...

Page 35: ...pplicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact your local...

Page 36: ...d Heating Cooling Water Heating P O Box 17010 Fort Smith Arkansas 72917 www ruud com In keeping with its policy of continuous progress and product improvement Ruud reserves the right to make changes w...