background image

Rely on Ruud.™

5

The entire cabinet has powder post paint (

) achieving 1000

hour salt spray rating, allowing the cabinet to retain its aesthetics
throughout its life.

Scroll compressors with standard internal pressure relief and
internal thermal overload are used on all capacities assuring
longevity of high efficient and quiet operation for the life of the
product.

Each unit is shipped with filter drier for field installation and will
trap any moisture or dirt that could contaminate the refrigerant
system. 

All cabinets have industry leading structural strength due to the
composite base pan (

), interlocking corner post (

), formed

curved louver panels (

) and drawn top cover (

) making it

the most durable cabinet on the market today. 

Each RA16 capacity has undergone rigorous psychometric test-
ing to assure performance ratings of capacity, SEER
and EER per AHRI Standard 210/240 rating condi-
tions. Also each unit bears the UL mark and each unit
is certified to UL 1995 safety standards.

Each unit has undergone specific strain and modal testing to
assure tubing (

) is outside the units natural frequency and that

the suction and discharge lines connected to the compressor
withstand any starting, steady state operation or shut down
forces imposed by the compressor. 

All units have been sound tested in sound chamber to AHRI 270
rating conditions, and A-weighted Sound Power Level tables
produced, assuring units have acceptable noise qualities (see
page 8). Each unit has been ran in cooling operation at 95°F and
82°F and sound ratings for the RA16 range from as low as 70.7
dBA to 76.6 dBA. 

All units have been ship tested to assure units meet stringent
“over the road” shipping conditions. 

As manufactured all units in the RA16 family have cooling capa-
bility to 55 °F. Addition of low ambient control will allow the unit
to operate down to 0°F. Factory testing is performed on each
unit. All component parts meet well defined specification and
continually go through receiving inspections. Each component
installed on a unit is scanned, assuring correct component uti-
lization for a given unit capacity and voltage. All condenser coils
are leak tested with pressurization test to 550#’s and once
installed and assembled, each units’ complete refrigerant
 system is helium leak tested. All units are fully charged from the
factory for up to 15 feet of piping. All units are factory run tested.
The RA16 has a 10-year conditional compressor and parts war-
ranty (registration required). 

Optional Accessories

(Refer to accessory chart for model #)

Compressor Crankcase Heater

Protects against refrigerant migration that can occur during low
ambient operation

Compressor Sound Cover

• Reinforced vinyl compressor cover containing a 1½ inch thick

batt of fiberglass insulation

• Open edges are sealed with a one-inch wide hook and loop

fastening tape

Compressor Hard Start Kit

• Single-phase units are equipped with a PSC compressor

motor, this type of motor normally does not need a potential
relay and start capacitor 

• Kit may be required to increase the compressor starting

torque, in conditions such as low voltage

Low Ambient Kit

• Air conditioners operate satisfactorily in the cooling mode

down to 55°F outdoor air temperature without any additional
controls

• This Kit can be added in the field enabling unit to operate

properly down to 0° in the cooling mode

• Crankcase heater and freezestat should be installed on com-

pressors equipped with a low ambient kit

3"/6"/12"

• Gray high density polyethylene feet are available to raise unit

off of mounting surface away from moisture

Low Pressure

• Can be added in field enabling the unit to shut off compressor

on loss of charge 

NOTE: Unit can be purchased with high and low pressure

installed at factory. (Refer to SKU list)

High Pressure

• Can be added in field enabling unit to shut off compressor if

unit loses outdoor fan operation.

NOTE: Unit can be purchased with high and low pressure

installed at factory. (Refer to SKU list)

Decorative Top

• Can be installed on fan grille 

25

20

22

21

24

23

20

24

23

22

21

25

Features & Benefits
RA16 Series

Summary of Contents for RA16 Series

Page 1: ...sound Rust resistant screws confirmed through 1500 hour salt spray testing PlusOne Expanded Valve Space 3 4 5 service valve space provides a minimum working area of 27 square inches for easier access...

Page 2: ...lectrical Data 8 Accessories 9 Weighted Sound Power 9 Thermostats 9 Unit Dimensions 10 Clearances 11 Wiring Diagrams 12 Application Guidelines 12 Refrigerant Line Size Information 13 14 Performance Da...

Page 3: ...1NA Achiever Series 4 ton 16 SEER Single Stage Air Conditioner 208 230 1 60 RA1660AJ1NA Achiever Series 5 ton 16 SEER Single Stage Air Conditioner 208 230 1 60 RA1618AJ1NB Achiever Series 1 1 2 ton 16...

Page 4: ...acitor needs to be replaced there is more than adequate space to make the repair Furthermore if high pressure and low pressure model was not purchased but is desired to be installed in the field the s...

Page 5: ...n and continually go through receiving inspections Each component installed on a unit is scanned assuring correct component uti lization for a given unit capacity and voltage All condenser coils are l...

Page 6: ...28 kW 24 24 000 7 03 kW 30 30 000 8 79 kW 36 36 000 10 55 kW 42 42 000 12 31 kW 48 48 000 14 07 kW 60 60 000 17 58 kW A 1st Design J 1ph 208 230 60 C 3ph 208 230 60 D 3ph 460 60 1 Single stage 2 Two s...

Page 7: ...5 75 000 22 kW 100 100 000 29 kW 125 125 000 37 kW 150 150 000 44 kW 3 up to 3 ton 4 2 1 2 to 4 ton 5 3 1 2 up to 5 ton 14 14 17 17 5 21 21 24 24 5 M Multi D Down Z Down zero clearance down flow X Low...

Page 8: ...e Hz 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 Maximum overcurrent protection amps 20 20 30 35 40 40 50 Minimum circuit ampacity 12 14 18 23 25 25 34 C...

Page 9: ...RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Solenoid Coil 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V 61 AMG120 240V Achiever Top Cap w Label 91 101123 21 91 1011...

Page 10: ...3 75 857 33 75 857 27 375 695 36 25 921 36 25 921 RA1630 27 685 35 75 908 35 75 908 27 375 695 38 25 972 38 25 972 RA1636 31 787 35 75 908 35 75 908 31 375 797 38 25 972 38 25 972 RA1642 39 990 35 75...

Page 11: ...Service 24 609 6 Service 24 609 6 Service 18 457 2 WALL WALL WALL WALL NOTE NUMBERS IN mm CLEARANCES IMPORTANT When installing multiple units in an alcove roof well or partially enclosed area ensure t...

Page 12: ...G W R TYPICAL THERMOSTAT SUBBASE X TYPICAL ELECTRIC HEAT LOW VOLTAGE JUNCTION BOX Application Guidelines 1 Intended for outdoor installation with free air inlet and outlet Outdoor fan external static...

Page 13: ...3 36 3 8 9 53 1 4 6 35 25 7 62 N R N R N R N R N R N R N R N R N R N R N R 5 16 7 94 25 7 62 50 15 24 60 18 29 45 13 72 35 10 67 20 6 1 5 1 52 N R N R N R N R N R 3 8 9 53 25 7 62 50 15 24 75 22 86 80...

Page 14: ...88 0 99 0 97 0 95 0 94 0 93 0 93 0 91 0 91 0 9 0 89 0 87 0 86 3 4 19 05 1 00 0 99 0 99 0 98 0 98 0 97 0 96 0 96 0 95 0 95 0 94 0 94 7 8 22 23 1 00 1 00 0 99 1 00 0 99 0 99 0 99 0 98 0 98 0 98 0 97 0 9...

Page 15: ...0 7 0 17500 5 1 6500 1 9 14 00 12 20 800 377 6 7940713 RCF2421HTAM RXMD C04 24000 7 0 17500 5 1 6500 1 9 14 00 12 20 800 377 6 7940680 RA1630AJ1 RCF3621MTAM RXMD C04 29600 8 7 21000 6 2 8600 2 5 14 50...

Page 16: ...7 20500 6 0 9100 2 7 16 00 13 00 875 413 0 7940931 RCF3621STAM 28400 8 3 21100 6 2 7300 2 1 16 00 13 00 875 413 0 7940975 RA1630AJ1 R801TA075417MSA RCF3617STAM 29000 8 5 22100 6 5 6900 2 0 16 00 13 0...

Page 17: ...RCF3621MTAM 36000 10 6 25100 7 4 10900 3 2 16 00 13 00 1275 601 7 7941818 RCF3621STAM 35200 10 3 24700 7 2 10500 3 1 15 50 13 00 1000 471 9 7941862 RA1636AJ1 R801TA075521ZSA RCF3621MTAM 36000 10 6 25...

Page 18: ...3 00 1100 519 1 7942646 RA1648AC1 R801TA075317ZSA RCF4821STAM 43500 12 7 29500 8 6 14000 4 1 15 50 13 00 1225 578 1 7942895 RA1648AC1 R801TA075417MSA RCF4821STAM 43500 12 7 29200 8 6 14300 4 2 16 00 1...

Page 19: ...00 1425 672 5 7943799 RA1660AC1 R801TA125524MSA RCF6024HTAM 58000 17 0 41600 12 2 16400 4 8 15 50 13 00 1650 778 7 7943771 RCF6024STAM 58000 17 0 41600 12 2 16400 4 8 15 50 13 00 1650 778 7 7943800 RA...

Page 20: ...5 1 6500 1 9 15 50 13 00 850 401 2 7940682 RA1624AJ1 R802VA075317MSA RCF2417HTAM 24000 7 0 17500 5 1 6500 1 9 16 00 13 00 875 413 0 7940578 RCF2417MTAM 24000 7 0 17500 5 1 6500 1 9 16 00 13 00 875 41...

Page 21: ...3 24400 7 2 10600 3 1 15 50 13 00 975 460 1 7941432 RA1636AC1 R802VA075317ZSA RCF3617STAM 35200 10 3 24900 7 3 10300 3 0 15 10 12 50 1050 495 5 7941360 RCF3621MTAM 36000 10 6 25100 7 4 10900 3 2 16 00...

Page 22: ...1 7 27500 8 1 12500 3 7 15 50 13 00 1100 519 1 7942231 RA1642AC1 R802VA075421ZSA RCF4821STAM 41000 12 0 29600 8 7 11400 3 3 15 50 13 00 1300 613 5 7942232 RCF4824HTAM 42000 12 3 31100 9 1 10900 3 2 16...

Page 23: ...0400 8 9 13600 4 0 15 50 13 00 1300 613 5 7943228 RCF4824HTAM 46000 13 5 33000 9 7 13000 3 8 16 00 13 00 1450 684 3 7943264 RCF4824STAM 44000 12 9 30400 8 9 13600 4 0 15 50 13 00 1300 613 5 7943299 RA...

Page 24: ...50 13 00 1500 707 9 7943554 RCF6024STAM 57000 16 7 39400 11 5 17600 5 2 15 50 13 00 1500 707 9 7943583 RA1660AJ1 R802VA125524MSA RCF6024HTAM 57500 16 9 40100 11 8 17400 5 1 16 00 13 00 1525 719 7 794...

Page 25: ...17MSA RCF3617STAM 28400 8 3 21200 6 2 7200 2 1 16 00 13 00 925 436 6 7940910 RCF3621MTAM 29800 8 7 21000 6 2 8800 2 6 16 00 13 00 950 448 4 7940942 RCF3621STAM 28600 8 4 21500 6 3 7100 2 1 16 00 13 00...

Page 26: ...01521MSA RCF4821STAM 41000 12 0 30200 8 9 10800 3 2 15 10 12 50 1400 660 7 7942575 RCF4824HTAM 42000 12 3 31100 9 1 10900 3 2 15 50 13 00 1425 672 5 7942617 RCF4824STAM 41000 12 0 30200 8 9 10800 3 2...

Page 27: ...15 10 12 50 1425 672 5 7943809 RA1660AJ1 R95TA0851521MSA RCF6024HTAM 56500 16 6 38700 11 3 17800 5 2 15 10 12 50 1475 696 1 7943557 RCF6024STAM 56500 16 6 38700 11 3 17800 5 2 15 10 12 50 1475 696 1 7...

Page 28: ...5 1 6500 1 9 15 50 13 00 850 401 2 7940632 RCF2421MTAM 24000 7 0 17500 5 1 6500 1 9 15 50 13 00 775 365 8 7940691 RA1624AJ1 R96VA0702317MSA RCF2417HTAM 24000 7 0 17500 5 1 6500 1 9 16 00 13 00 775 36...

Page 29: ...00 7 4 10900 3 2 16 00 13 00 1250 589 9 7941481 RCF3624MTAM 36000 10 6 25100 7 4 10900 3 2 16 00 13 00 1250 589 9 7941515 RA1636AC1 R96VA1152524MSA RCF3624HTAM 36000 10 6 25100 7 4 10900 3 2 16 00 13...

Page 30: ...CF4824STAM 44000 12 9 30400 8 9 13600 4 0 15 50 13 00 1300 613 5 7942981 RA1648AC1 R96VA1002521MSA RCF4821STAM 44000 12 9 30700 9 0 13300 3 9 15 50 13 00 1350 637 1 7942909 RCF4824HTAM 46000 13 5 3310...

Page 31: ...1 7941769 RF1P3624STAN 36000 10 6 25100 7 4 10900 3 2 14 50 12 20 1100 519 1 7943763 RF1T3624MTAN 36000 10 6 25100 7 4 10900 3 2 16 00 13 00 1025 483 7 7941770 RBHP 21 36000 10 6 25100 7 4 10900 3 2 1...

Page 32: ...00 1500 707 9 7943534 RH1T4821STAN 45000 13 2 32000 9 4 13000 3 8 16 00 13 00 1400 660 7 7943535 RH1T4824STAN 45500 13 3 33500 9 8 12000 3 5 16 00 13 00 1550 731 5 7943536 RH2T4824MTAN 46500 13 6 331...

Page 33: ...10 6 25100 7 4 10900 3 2 16 00 13 00 1000 471 9 7941853 RCF3621STAM 35000 10 3 24400 7 2 10600 3 1 15 10 12 50 975 460 1 7941897 RA1642AC1 RHWB 04WMX36B RCF4821STAM 40500 11 9 28600 8 4 11900 3 5 15...

Page 34: ...ondenser fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts wi...

Page 35: ...pplicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact your local...

Page 36: ...d Heating Cooling Water Heating P O Box 17010 Fort Smith Arkansas 72917 www ruud com In keeping with its policy of continuous progress and product improvement Ruud reserves the right to make changes w...

Reviews: