23
ACCESSORIES
COMMON SUPPLY/RETURN
CONCENTRIC AIR DIFFUSER
SUPPLY AIR/PERFORMANCE
NOTE:
The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomforta-
ble conditions.
Accessory
Approximate CFM [L/s]-Supply Air
.12 [.030]
.07 [.017] .10 [.024]
Plenum & Supply/Return Duct
1575 [743] 1800 [850]
1300 [614]
.16 [.040]
.09 [.022] .13 [.032]
Diffuser
.11 [.027]
.06 [.015] .09 [.022]
Economizer
.17 [.042]
.24 [.060]
.17 [.042]
2200 [1038]
Diffuser Airflow CFM [L/s]
Range of Throw Ft. [m]
14 [4.27]-16 [4.88]
800 [378]-1200 [566]
18 [5.49]-28 [8.53]
1600 [755]-2000 [944]
ACCESSORY EQUIPMENT
Accessory
Description
Model
Application
Accessory
Model No.
Roofcurbs
RQNA-B
RXQG-AAA14 (14" [356 mm] Height)
RXQG-AAA24 (24" [610 mm] Height)
Supply & Return Diffusers
RQNA-B
RXRN-BD15
Economizers (Downflow Only)
RQNA-B
RXRE-CAA30 (3 Position)
RXRD-CAM10 (Fully Modulating)
Fresh Air Damper
RQNA-B
RXRF-FAB1 (Motorized-35%)
RXRF-FAA1 (Fixed-35%)
Rectangular to Round Transition (Downflow)
RQNA-B
RXMC-CA02 (16" [406 mm] Ducts)
RXMC-CA03 (18" [457 mm] Ducts)
Filter Kit
RQNA-B
RXRY-B01
High Pressure Control
RQNA-B
RXAB-A04
Outdoor Thermostat
RQNA-B
RXPT-A01
Duct Adapter Sideflow Square to Round Transition
RQNA-B
RXMC-BA01
Low Ambient Control
RQNA-B
RXPZ-C01 or RXPZ-F01
Economizers (Sideflow Only)
RQNA-B
RXRD-CCM10 (Fully Modulating)
Designed to convert a side by side or an over and under arrange-
ment into a concentric distribution of air. The diffuser is flush
mounted, completely insulated, assembled, and internally baffled
to provide four way supply air distribution with a center return. To
make the assembly complete and ready to fit into a 2' [0.61 m] x 4'
[1.22 m] suspended ceiling grid, the diffuser includes adjustable
supply louvers, hanging rings, anti-sweat gasket, and round
flanges for use with flexible ducts.
Model No.
RXRN-
Diameter
Inches [mm]
16 [406]
90 [40.82]
Shipping Wt.
Lbs. [kg]
Dimension A
Inches [mm]
20
1
/
2
[521]
BD15
SUPPLY/RETURN DIFFUSER
AIRFLOW/PRESSURE DROP
INFORMATION (INCHES W.C. [kPa])
NOTE:
The location of the combination supply and return diffuser should
not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM
[472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level
for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed
with a greater distance than recommended above, the supply air may
become stratified above the required comfort area causing uncomforta-
ble conditions.
[
] Designates Metric Conversions
Summary of Contents for RQNA-B024JK
Page 22: ...22 TYPICAL INSTALLATIONS Designates Metric Conversions Designates Metric Conversions...
Page 31: ...31 WIRING SCHEMATICS RQNA B SERIES...
Page 32: ...32 WIRING SCHEMATICS RQNA B SERIES...
Page 33: ...33 WIRING SCHEMATICS RQNA B SERIES...
Page 34: ...34 WIRING SCHEMATICS RQNA B SERIES...
Page 35: ...35 NOTES...