17.0

10.0

 

USES LESS ENERGY

Seasonal Energy Efficiency Ratio -

 

SEER

17.00

“Proper sizing and installation of equipment is critical to achieve optimal

performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet Energy Star. 
Ask your Contractor for details or visit www.energystar.gov.”

UA17 Series

Efficiencies up to 17 SEER/13 EER
Nominal Sizes 2, 3, 4 & 5 Ton 
[7.03, 10.6, 14.06 & 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]

FORM NO. A22-223 REV. 3

Air Conditioners
UA17 Series

Rely on Ruud.™

Ruud

Achiever Plus

Series

Two-Stage Air Conditioners

Ruud

Achiever Plus

Series

Two-Stage Air Conditioners

• EcoNet

Enabled product. The EcoNet Smart Home System

provides advanced air & water control for maximum energy
savings and ideal comfort. 

• New composite base pan – dampens sound, captures louver

panels, eliminates corrosion and reduces number of fasteners
needed

• Powder coat paint system – for a long lasting professional finish
• The Two Stage Copeland Scroll

UltraTech

Compressor

modulates between two capacity settings  – 67% and 
100% – providing more precise temperature control, lower
humidity and greater efficiency in comparison to single stage
compressors. It uses 70% fewer moving parts which also
increases efficiency and reliability.

• Modern cabinet aesthetics – increased curb appeal with visu-

ally appealing design

• Curved louver panels – provide ultimate coil protection,

enhance cabinet strength, and increased cabinet rigidity

• Optimized fan orifice – optimizes airflow and reduces unit

sound

• Rust resistant screws – confirmed through 1500-hour salt 

spray testing

• PlusOne™ 

Expanded Valve Space

– 3"-4"-5" service valve

space – provides a minimum working area of 27-square inches
for easier access   

• PlusOne™ 

Triple Service Access

– 15" wide, industry lead-

ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly

• Diagnostic service window with two-fastener opening –

 provides access to the high and low pressure.

• External gauge port access – allows easy connection of 

“low-loss” gauge ports

• Single-row condenser coil – makes unit lighter and allows

 thorough coil cleaning to maintain “out of the box”
performance

• 35% fewer cabinet fasteners and fastener-free base – allow 

for faster access to internal components and hassle-free 
panel removal

• Service trays – hold fasteners or caps during service calls
• QR code – provides technical information on demand for

faster service calls

• Fan motor harness with extra long wires allows unit top to be

removed without disconnecting fan wire.

• High and low pressure standard on all models.

Summary of Contents for UA1724A

Page 1: ...and reliability Modern cabinet aesthetics increased curb appeal with visu ally appealing design Curved louver panels provide ultimate coil protection enhance cabinet strength and increased cabinet rig...

Page 2: ...on 7 8 General Data Electrical Data 9 Accessories 10 Weighted Sound Power 10 Smart Home Systems 11 12 Unit Dimensions 13 Clearances 14 Wiring Diagrams 15 16 Application Guidelines 15 16 Refrigerant Li...

Page 3: ...release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Single row condenser coil Powder coated paint Rust resistant screws QR code External gauge ports Service trays...

Page 4: ...and hookup of low loss refrig erant gauges and access to the service valve caps for opening For applications with long line lengths up to 250 feet total equivalent length up to 200 feet condenser abov...

Page 5: ...it has been ran in cooling operation at 95 F and 82 F and sound ratings for the UA17 range from as low as 72 3 dBA to 76 7 dBA All units have been ship tested to assure units meet stringent over the r...

Page 6: ...a home s Heating Cooling and Water Heating systems and is required to operate an EcoNet Enabled Heating Cooling system in a fully communicating mode WiFi Kit for Heating and Cooling Systems The WiFi k...

Page 7: ...30 30 000 8 79 kW 36 36 000 10 55 kW 42 42 000 12 31 kW 48 48 000 14 07 kW 60 60 000 17 58 kW A 1st Design J 1ph 208 230 60 C 3ph 208 230 60 D 3ph 460 60 1 Single stage 2 Two stage V Inverter P Pisto...

Page 8: ...kW 125 125 000 37 kW 150 150 000 44 kW 3 up to 3 ton 4 2 1 2 to 4 ton 5 3 1 2 up to 5 ton 14 14 17 17 5 21 21 24 24 5 M Multi D Down Z Down zero clearance down flow X Low Nox S Standard A 1st Design...

Page 9: ...850 820 646 825 watts 112 112 132 113 Shipping weight lbs 200 209 297 298 Operating weight lbs 193 202 290 291 Electrical Data Line Voltage Data Volts Phase Hz 208 230 1 60 208 230 1 60 208 230 1 60 2...

Page 10: ...Solenoid 24 VAC 50 60 Hz Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC Solenoid Coil 61 AMG24V 61 AMG24V 61 AMG24V 61 AMG24V Liquid Line Solenoid 120 240 VAC 50 60 Hz Solenoid Va...

Page 11: ...Module EcoNet app for smart phones and tablets Warranty 5 Year limited warranty from date of installation Source Department of Energy When compared to non programmable thermostats Source ENERGY STAR f...

Page 12: ...tus Internet Connection Status WLAN SETUP factory reset button WiFi Kit Components EcoNet WiFi Module Installation Instructions V Power Adapter Junction Box 24 Port to Port Connection Cable 1 x 2 Doub...

Page 13: ...HES mm INCHES mm INCHES mm INCHES mm INCHES mm UA1724 35 889 33 75 857 33 75 857 36 75 933 36 38 924 36 38 924 UA1736 39 990 33 75 857 33 75 857 40 75 1035 36 38 924 36 38 924 UA1748 51 1295 35 75 908...

Page 14: ...304 8 6 152 4 24 609 6 Service 24 609 6 Service 24 609 6 Service 18 457 2 WALL WALL WALL WALL NOTE NUMBERS IN mm CLEARANCES IMPORTANT When installing multiple units in an alcove roof well or partially...

Page 15: ...an external static pressure available is less than 0 01 in wc 2 Minimum outdoor operation air temperature for cooling mode without low ambient operation accessory is 55 F 12 8 C 3 Maximum outdoor oper...

Page 16: ...INFORMATION Factory Standard ODD R Y1 Y2 G W2 R Y1 C L Y Y BL R BR W R DHM L W1 FIGURE 6 CONDENSING UNIT WITH ELECTRIC HEAT USING A TWO STAGE THERMOSTAT WITH DEHUMIDIFICATION WIRE COLOR CODE BK BLACK...

Page 17: ...67 30 9 14 7 16 11 12 25 7 62 50 15 24 75 22 86 75 22 86 75 22 86 75 22 86 70 21 34 70 21 34 70 21 34 65 19 81 65 19 81 60 18 29 1 2 12 71 25 7 62 50 15 24 75 22 86 80 24 38 80 24 38 80 24 38 80 24 38...

Page 18: ...0 96 0 96 0 95 0 95 7 8 22 23 1 01 1 00 1 00 1 00 0 99 0 99 0 99 0 99 0 99 0 99 0 99 0 99 1 25 4 1 01 1 01 1 01 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 00 1 1 8 28 58 N R N R N R N R N R N R N R N...

Page 19: ...6 26000 7 6 10000 2 9 17 00 13 00 1075 507 3 8232069 RCF6021SEAM 36000 10 6 26000 7 6 10000 2 9 17 00 13 00 1075 507 3 8232078 UA1736AJ2 U802VA075317ZSA RCF3621MEAM 36000 10 6 26000 7 6 10000 2 9 17...

Page 20: ...0000 2 9 17 00 13 00 1050 495 5 8232084 UA1736AJ2 U96VA0852521MSB RCF3621MEAM 36000 10 6 26000 7 6 10000 2 9 16 50 13 00 1075 507 3 8232076 RCF6021SEAM 36000 10 6 26000 7 6 10000 2 9 17 00 13 00 1075...

Page 21: ...17 1 1 2 TO 5 NOMINAL TONS Fans Condenser fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanen...

Page 22: ...e within the applicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions cont...

Page 23: ...Rely on Ruud 23 Notes UA17 Series...

Page 24: ...ud Heating Cooling Water Heating P O Box 17010 Fort Smith Arkansas 72917 www ruud com In keeping with its policy of continuous progress and product improvement Ruud reserves the right to make changes...

Reviews: