Rely on Ruud.™
9
General Data/Electrical Data
UA17 Series
Physical Data
Model No.
UA1724A
UA1736A
UA1748A
UA1760A
Nominal Tonnage
2.0
3.0
4.0
5.0
Valve Connections
Liquid Line O.D. – in.
3/8
3/8
3/8
3/8
Suction Line O.D. – in.
3/4
3/4
7/8
7/8
Refrigerant (R-410A) furnished oz.¹
128
151
204
223
Compressor Type
Scroll
Outdoor Coil
Net face area – Outer Coil
19.8
22.2
32.3
32.3
Net face area – Inner Coil
—
—
—
—
Tube diameter – in.
0.375
0.375
0.375
0.375
Number of rows
1
1
1
1
Fins per inch
20
22
22
22
Outdoor Fan
Diameter – in.
24
24
26
26
Number of blades
3
3
3
3
Motor hp
1/5
1/5
1/2
1/2
CFM
3326
3540
4251
5133
RPM
850
820
646
825
watts
112
112
132
113
Shipping weight – lbs.
200
209
297
298
Operating weight – lbs.
193
202
290
291
Electrical Data
Line Voltage Data (Volts-Phase-Hz)
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
Maximum overcurrent protection (amps)²
25
35
50
70
Minimum circuit ampacity³
16
21
32
42
Compressor
Rated load amps
11.7
15.3
21.2
28.8
Locked rotor amps
58.3
83
104
152.9
Condenser Fan Motor
Full load amps
1.4
1.2
5.3
5.3
Locked rotor amps
—
—
—
—
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.