Installation, operating and maintenance manual SKIT/S-DEB
3rd print version
page 43
7 – Commissioning
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
SKIT/S-DEB 0,25) The housing consists of sheet steel and
has protection rating IP 56. The supply (pos.2
à
3.1) is
done through a brass cable connection.
The line cross-section must be measured and fused acc.
to chapter 3.14.2, depending on the oil separator power.
The 4 LEDs in the control box door indicate the basic
functions. The oil sepparator system can be started and
the operating modes selected via a main switch and a
switch "Hand"-"Zero"-"Auto". There are terminals for two
level switches in the bilge in order to switch automatic
mode of the system on or off depending on the level. By
factory default the terminals of the floating switches are
bridged.
For a detailled description of the oil separator control
system with micro processor see chapter
à
3.15.
7.9
Electrical connections of oil separator control system
See electric diagram