9 – Process description
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
with the 15ppm Bilge Alarms, the following precautions
should be taken:
Every access of the 15ppm Bilge Alarm beyond the
essential requirements of paragraph 4.2.8 of the
MEPC.107(49), requires the breaking of a seal.
The 15ppm Bilge Alarm should be so constructed that the
alarm is always activated whenever clean water is used
for cleaning or zeroing purposes.
The Bilge Alarm Monitor OMD complies with the above
rules. The measuring cell can be removed for calibration
while the control device remains on the oily water
separator to keep the recorded data on board for at least
18 months.
A 3-way valve for flushing is fitted with a contact to ensure
that during flushing of the alarm monitor an overboard
discharge of polluted water is not possible.