10 – Operation
RWO GmbH
●
Marine Water Technology
●
Bremen
●
Germany
Issue 2014-04-10
WARNING
The values for oil and water detection must not be
changed without consulting RWO service!
Incorrect settings can cause severe functional
failures!
Note
See
à
10.5.5 Notes on input mapping
OEL-ERKENNUNG > %
AENDERN? NEIN JA
OIL IDENT > %
MODIFY? NO YES
After pressing the Enter button, the set value and the
possible value range are displayed. The first digit of the
value flashes and can be modified with the -/+buttons. The
process is the same as in entering the password.
OEL-ERKENNUNG > %
WERT :055
(000..100)
OIL IDENT > %
VALUE:055
(000..100)
WASSER-ERKENNUNG> %
WERT :048
(000..100)
WATER IDENT > %
VALUE:048
(000..100)
After entering the last digit and pressing the Enter button,
the display prompts for confirmation to save the new
value.
OEL-ERKENNUNG > %
SPEICHERN? NEIN JA
OIL IDENT > %
STORE? NO YES
With the -/+ button you can now select "Yes". Pressing the
Enter button confirms the new value (if the entered value
is beyond the permissible range, it will automatically be set
to the limit value). This exits the function to change this
setting, the next user setting is queried for changes.
You can cancel the changes to the user settings any time
without changes by pressing the ESC button. The menu
then goes up to the level where the prompt asks for
changes to the user settings.
SPUELZEIT SEK.
AENDERN? NEIN JA
FLUSHING TIME SEC.
MODIFY? NO YES
The flushing times depend on the oil separator
performance, the factory settings are as follows:
SKIT 0.1
0.25 0.5
1.0
1.5
2.5
5.0
10.0
Sec. 8
12
15
20
25
30
40
50
Tab. 15 Factory settings