proper outlet installed by a qualified electrician.

 WARNING

Improper installation of the grounding plug could result in a 

risk of electric shock. The wire with green-colored insulation 

(with or without yellow stripes) is the grounding wire.

Check with a qualified electrician or service personnel if 

the grounding instructions are not completely understood 

or if in doubt as to whether the product is properly 

grounded. Repair or replace a damaged or worn cord 

immediately. Only connect the product to an outlet having 

the same configuration as the plug. Do not use an adapter 

with this product.
Residual current device (RCD) protection should be 

provided on the circuit(s) or outlet(s) to be used for the 

air station. Outlets are available having built-in RCD 

protection and may be used for this measure of safety.
If the air station is used with an extension cord, ensure the 

connection of the power cord of the tool and the extension 

cord are not on the ground. Auxiliary devices should always 

be plugged into the wall outlet and not at the connection of 

an extension cord and the power cord of the tool.
If a protected outlet is not available, do not use the 

air station until an outlet can be changed or auxiliary 

protection can be obtained. These auxiliary protection 

devices are available at your local retailer.

SPECIFICATIONS

Air tank capacity

10 L

Air delivery 

56 L/min @ 6.2 bar 

Air pressure

9.3 bar max

Input

240 V, AC only, 50 Hz, 

1100 W

Tank pressure gauge

38 mm diameter

Regulatory pressure 

gauge

50 mm diameter

Net weight

14.5 kg

KNOW YOUR AIR STATION
See Figure 2.

The safe use of this product requires an understanding 

of the information on the product and in this operating 

manual as well as a knowledge of the project you are 

attempting. Before use of this product, familiarize yourself 

with all operating features and safety rules.

Accessory storage

The air station features a storage space for pneumatic 

accessories.

Carry handle

The air station has a carry handle for easy transport.

Cord wrap

The cord wrap keeps the cord neatly out of the way for 

storage.

Drain valve

The drain valve on the tank is for draining condensation to 

help prevent tank corrosion.

Folding handle and hand grips

The air station is equipped with conveniently placed hand 

grips for lifting and a folding handle that can be adjusted 

for storage and transportation.

Heavy-duty plastic housing

The sturdy plastic housing frames the air station to help 

protect the gauges and controls from damage due to 

impact.

Integrated coil hose retainer with 7.6 m air hose

This tool is equipped with an integrated coil hose retainer 

feature that will hold up to 7.6 m of coiled 6.4 mm air hose. 

A 7.6 m coiled hose is included with your air station.

Oil-free pump

The oil-free pump reduces the need for maintenance.

Pressure regulator knob

Use the pressure regulator knob to adjust the amount of 

air being delivered through the hose. Pressing down on 

the knob will lock it into place. This prevents movement of 

the knob caused by vibration during use.

Quick coupler

The air station has a 6.4 mm quick connect coupler 

located on the side of the unit.

Regulator pressure gauge

The current line pressure is displayed on the regulator 

pressure gauge. This pressure can be adjusted by rotating 

the pressure regulator knob.

Safety valve

The safety valve is designed to automatically release air if 

the air tank pressure exceeds the preset maximum.

Summary of Contents for ERC1512

Page 1: ...ERC1512 OWNER S OPERATING MANUAL ORIGINAL INSTRUCTIONS ...

Page 2: ...Fig 1 1 2 Fig 2 17 16 12 13 20 15 14 11 19 18 E 6 9 10 3 4 8 5 7 ...

Page 3: ...10 A 14 Fig 6 Fig 9 Fig 8 Fig 4 Fig 5 16 5 8 3 4 18 Fig 7 15 Fig 3 ...

Page 4: ...Fig 12 Fig 11 8 5 3 4 Fig 13 6 Fig 10 9 21 11 22 ...

Page 5: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications ...

Page 6: ...d to carry the tool or pull the plug from an outlet Keep cord away from heat oil sharp edges or moving parts Replace damaged cords immediately Damaged cords increase the risk of electric shock d When operating a power tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electric shock 3 PERSONAL SAFETY a Use safety equipment Always...

Page 7: ...servicing a tool use only identical replacement parts Follow instructions in the Maintenance section of this manual Use of unauthorized parts or failure to follow Maintenance instructions may create a risk of injury SPECIAL SAFETY RULES 1 Know your air station Read operation manual carefully Learn its applications and limitations as well as the specific potential hazards related to this tool Follo...

Page 8: ...mber the heavier the cord An undersized cord will cause a drop in line voltage resulting in loss of power and overheating 29 This equipment incorporates parts such as snap switches receptacles and the like that tend to produce arcs or sparks and therefore when located in a garage it should be in a room or enclosure provided for the purpose or should be 457 mm or more above the floor 30 Never store...

Page 9: ... requires an understanding of the information on the product and in this operating manual as well as a knowledge of the project you are attempting Before use of this product familiarize yourself with all operating features and safety rules Accessory storage The air station features a storage space for pneumatic accessories Carry handle The air station has a carry handle for easy transport Cord wra...

Page 10: ...t may cause damage to the unit APPLICATIONS Air stations are utilized in a variety of air system applications Match hoses connectors air tools and accessories to the capabilities of the air station You may use this product for the purposes listed below operating some air powered tools operating air accessories such as air nozzles and inflators operates some air powered paint spraying products TRAN...

Page 11: ...NG Never exceed the pressure rating of the tool as recommended by the manufacturer When using this air station as an inflation device always follow the maximum inflation guidelines stated by the manufacturer of the item being inflated WARNING Always ensure the switch is in the OFF position and the regulator pressure gauge reads zero Pa before changing air tools or disconnecting the hose from the a...

Page 12: ...tion of the quick reference label 6 Tilt tank to drain moisture from tank into a suitable container NOTE Condensate is a polluting material and should be disposed of in compliance with local regulations 7 If drain valve is clogged release all air pressure remove and clean valve then reinstall WARNING Unplug the air station and release all air from the tank before servicing Failure to depressurize ...

Page 13: ...ps and grindings are highly abrasive to bearings brushes commutators etc Consequently we do not recommend using this product for extended work on these types of materials However if you do work with any of these materials it is extremely important to clean the product using compressed air LUBRICATION All of the bearings in this product are lubricated with a sufficient amount of high grade lubrican...

Page 14: ...rical shock Hazardous voltage Disconnect from power source before serivcing Compressor must be grounded If connected to a circuit protected by fuses use time delay fuses with this product This equipment incorporates parts such as snap switches receptacles and the like that tend to produce arcs or sparks and therefore when located in a garage it should be in a room or enclosure provided for the pur...

Page 15: ...TECHTRONIC INDUSTRIES AUSTRALIA PTY LTD Level 1 666 Doncaster Road Doncaster Victoria 3108 Australia Tel 61 3 9840 3226 Fax No 613 9840 6133 ...

Reviews: