background image

9

 WARNING

Do not use any attachments or accessories not 
recommended by the manufacturer of this tool. The use 
of attachments or accessories not recommended can 
result in serious personal injury.

LUBRICATION

$Q

DXWRPDWLF

LQOLQH

¿OWHUUHJXODWRUOXEULFDWRU

LV

UHFRPPHQGHG)LJDVLWLQFUHDVHVSURGXFWOLIHDQGNHHSV

the product in sustained operation. The in-line lubricator 

VKRXOGEHUHJXODUO\FKHFNHGDQG¿OOHGZLWKDLUWRRORLO

Proper adjustment of the in-line lubricator is performed by 
placing a sheet of paper next to the exhaust ports and 
actuate the tool 10 - 15 times without fasteners loaded. 
The lubricator is properly set when a light stain of oil 
collects on the paper. Excessive amounts of oil should be 
avoided.
If it becomes necessary to store the product for an extended 

SHULRGRIWLPHRYHUQLJKWZHHNHQGHWFLWVKRXOGUHFHLYH

a generous amount of lubrication at that time. Actuate the 
tool 10 - 15 times without fasteners loaded to ensure oil 
has been evenly distributed throughout the product. The 
product should be stored in a clean and dry environment. 

 

Ɣ

It is most important that the product be properly 

lubricated by keeping the air line lubricator filled 

and correctly adjusted. Without proper lubrication 

the product will not work properly and parts will 

wear prematurely.

Use correct lubricant in the air line lubricator. The 

lubricator should be of low air flow or changing air flow 

type, and should be kept filled to the correct level. Use only 

recommended lubricants, specially made for pneumatic 

applications. Substitutes may harm the rubber compounds 

in the product's O-rings and other rubber parts.

IMPORTANT!

6HH¿JXUH

,I D ¿OWHUUHJXODWRUOXEULFDWRU LV QRW LQVWDOOHG RQ WKH DLU

system, air operated tools should be lubricated at least 
once a day or after 2 hours of work with 2 - 6 drops 
of oil, depending on the work environment, directly 

WKURXJKWKHPDOH¿WWLQJLQWKHWRROKRXVLQJ

20140515v1

Summary of Contents for RA-NF90-K

Page 1: ...R FRAMING NAILER OPERATOR S MANUAL ORIGINAL INSTRUCTIONS RA NF90 K Important It is essential you read the instructions in this manual before starting and operating this machine 6XEMHFW WR WHFKQLFDO PR...

Page 2: ...6 5 4 7 8 DESCRIPTION 1 Nitto style coupler 2 Exhaust cap 3 Air supply 4 Nails 5 Pusher 6 Magazine 7 Trigger 8 Depth adjustment knob 9 Stopper 10 Flat blade screwdriver 11 Safety yoke 12 Hex screw 13...

Page 3: ...ick connector Lubricator Filter Cut off valve Regulator 0 8 5 bar Quick coupler Tool Air compressor Quick coupler Air hose Fig 8 Fig 12 Fig 11 Fig 9 Fig 13 1 2 5 13 4 12 6 10 Fig 10 2 1 1 2 5 9 4 4 6...

Page 4: ...ward or off balanced postures The operator should change posture during extended tasks which can help avoid discomfort and fatigue If the operator experiences symptoms such as persistent or recurring...

Page 5: ...manufacturer s authorized agents or by other experts having due regard to the information given in the operating instructions Stands for mounting the fastener driving tools to a support for example t...

Page 6: ...lved Compressed air pipelines should be laid so as to form a gradient highest point in the direction to the FRPSUHVVRU DVLO DFFHVVLEOH ZDWHU VHSDUDWRUV should be installed at the lowest points Junctio...

Page 7: ...njury ASSEMBLY UNPACKING This product has been shipped completely assembled Carefully remove the tool and any accessories from the box Make sure that all items listed in the packing list are included...

Page 8: ...er woods WARNING Disconnect the tool from the air supply before removing or replacing the no mar pad Failure to do so could result in serious personal injury The pad can be removed by pulling it down...

Page 9: ...sts against the end of the fastener strip NOTE Do not allow the pusher to snap back into place WARNING Use only the fasteners recommended for use with this tool The use of any other fasteners can resu...

Page 10: ...rial used for the actual job Drive a test fastener with the air pressure set at 6 2 6 5 EDU SVL 5DLVH RU ORZHU WKH DLU SUHVVXUH WR QG the lowest setting that will perform the job with consistent resul...

Page 11: ...mful to O rings and seals Do not use these low temperature air dryers without checking compatibility AIR SUPPLY PRESSURE AND VOLUME Air volume is as important as air pressure The air volume supplied t...

Page 12: ...t of lubrication at that time Actuate the tool 10 15 times without fasteners loaded to ensure oil has been evenly distributed throughout the product The product should be stored in a clean and dry env...

Page 13: ...damaged O rings or seals Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Verify adequate air supply Inadequate lubrication Lubricate tool Worn or damaged O rings or...

Page 14: ...X 2 65 32 O ring 16 x 1 6 54 O ring 1 7 X 2 76 Fixed seat 11 O ring 63 x 2 65 33 Valve sleeve 55 Safety stand 77 H QXW ZLWK DQJH 0 12 Head valve 34 O ring 6 1 X 1 8 56 C ring D 3 78 Hex socket bolt M6...

Page 15: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand...

Reviews: