RG-3500

NOTICE:

SINGLE PHASE

 2 STROKE

PETROL GENERATIN

G SET

Automatic voltage regu

lator

You must pour the o

il into the crankcase

 before use.

Please read the instruction abo

ut the relevant details.

Among the engi

ne exhaust 

emissions,

there will be CO, 

so never use in an

 

enclosed room 

without good 

ventiation

When the oil level is too low, the engine oil
warning system will be automatic to stop
running trom damaging the engine.

YEAR2015

Rated voltage ...........

...................................

.... 230V

Rated frequ

ency..............................

................ 50Hz

Rated Power ...

...................................

.............2.5kW

Rated Power Factor .

...................................

....... 1.0

Altitude Ratin

g ...............................

.............. 1000m

Rated Curre

nt ...............................

................. 10.7A

Performance Cl

ass .............................

................ G1

Mass ..........................

...................................

.. 44kgs

WARNING

ENGINE OIL

 WARNING SYSTE

M

6

7

4

3

1

5

6

Upper level

Oil filler cap

Oil filler hole

Summary of Contents for RG-3500

Page 1: ...ons there will be CO so never use in an enclosed room without good ventiation When the oil level is too low the engine oil warning system will be automatic to stop running trom damaging the engine YEA...

Page 2: ...ill be CO so never use in an enclosed room without good ventiation When the oil level is too low the engine oil warning system will be automa tic to stop running trom damagi ng the engine YEAR201 5 Ra...

Page 3: ...2 5 6 7 8 9 10 3 4 ON CLOSE OPEN OFF ON START ENG SW OFF ON START ENG SW...

Page 4: ...3 11 12 13 14 15 16 OFF Fuel filter cup Fuel valve OFF ON START ENG SW Drain plug Element 17 18 0 7 0 8mm Plug wrench Plug cap Filler cap Air cleaner cover Cover spring Cover spring...

Page 5: ...protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Avoid accidental starting Ensure the...

Page 6: ...to prepare it for operation ADD OIL USING THE GENERATOR FOR THE FIRST TIME SUBSEQUENT USE OF THE GENERATOR CAUTION Do not apply engine oil with additives or 2 stroke petrol engine oil as they haven t...

Page 7: ...output ability of the generator covers this extra power requirement The total running wattage requirement of the electrical devices connected to the generator should not exceed the Rated power of the...

Page 8: ...ance please take off the key and spark plug cap CLEANING THE GENERATOR Always try to use your generator in a cool dry place However in the event your generator becomes dirty you may clean the exterior...

Page 9: ...ed or chipped discard and replace with a new spark plug 4 Measure the plug gap with a gauge Fig 18 The gap should be 0 7 0 8mm 0 028 0 031 in 5 If you are re using the spark plug use a wire brush to c...

Page 10: ...level surface to prevent low oil shutdown from triggering Engine will not start Circuit breaker is off Set the circuit breaker to the on position Bad connecting wires cables If you are using an exten...

Page 11: ...10 NOTE...

Page 12: ......

Reviews: