5
English
GB
FR
DE
ES
IT
NL
PT
DK
SE
FI
NO
RU
PL
CZ
HU
RO
LV
LT
EE
HR
SI
SK
GR
TR
OPERATION
DC VOLTAGE
Range
Resolution
Accuracy
400mV
0.1mV ±(1.0%+5)
4V
0.001V
±(0.8%+3)
40V
0.01V
400V
0.1V
600V
1V
±(1.0%+3)
Input Impedance:
Range 400mV: >1000M
The other ranges: 10M
NOTE:
The 600V range is specified from 20% to 100%
of range.
AC VOLTAGE
Range
Resolution
Accuracy
4V
0.001V
±(1.0%+5)
40V
0.01V
400V
0.1V
600V
1V
±(1.2%+5)
Input Impedance:
10M
Frequency Range:
40Hz ~ 400 Hz
Response:
Average, calibrated in rms of sine wave
NOTE:
The 600V range is specified from 20% to 100%
of range.
DC CURRENT
Range
Resolution
Accuracy
400A
0.1A
±(1.2%+3)
4000A
1A
±(1.0%+3)
40mA
0.01mA
±(1.5%+3)
400mA
0.1mA
±(1.0%+3)
4A
0.001A
±(1.8%+3)
10A
0.01A
±(2.0%+5)
Overload Protection:
Fuse 1: F 400mA, 690V
Fuse 2: F 10A, 600V/690V
Max. Input Current:
10A (For inputs > 2A : measurement
duration < 10 sec, interval >15 minutes)
Max. Measurement Voltage Drop:
200mV (for all DC
current ranges except 10A range)
NOTE:
The 10A range is specified from 20% to 100% of
range.
AC CURRENT
Range
Resolution
Accuracy
400A
0.1A
±(1.5%+5)
4000A
1A
40mA
0.01mA
±(1.8%+5)
400mA
0.1mA
4A
0.001A
±(2.0%+5)
10A
0.01A
±(2.5%+10)
Overload Protection:
Fuse 1: F 400mA, 690V
Fuse 2: F 10A, 600V/690V
Max. Input Current:
10A (For inputs > 2A : measurement
duration < 10 sec, interval >15 minutes)
Frequency Range:
40Hz ~ 400 Hz
Response:
Average, calibrated in rms of sine wave
Max. Measurement Voltage Drop:
200mV (for all AC
current ranges except 10A range)
NOTE:
The 10A range is specified from 20% to 100% of
range.
RESISTANCE
Range
Resolution
Accuracy
400
0.1
±(1.0%+5)
4k
0.001k
±(1.0%+3)
40k
0.01k
400k
0.1k
4M
0.001M
40M
0.01M
±(1.8%+5)
Overload Protection:
600V DC/AC rms
CAPACITANCE
Range
Resolution
Accuracy
40nF
0.01nF
±(4%+20)
400nF
0.1nF
±(3%+5)
961067398-01.indd Sec1:5
961067398-01.indd Sec1:5
1/28/10 2:16:54 PM
1/28/10 2:16:54 PM
Summary of Contents for RP4020