EXTENSION CORDS

When using a power tool at a considerable distance from 
a power source, be sure to use an extension cord that has 
the  capacity  to  handle  the  current  the  tool  will  draw.  An 
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When working outdoors with a tool, use an extension cord 
that is designed for outside use. This type of cord is desig-
nated with “WA” on the cord’s jacket.
Before  using  any  extension  cord,  inspect  it  for  loose  or 
exposed wires and cut or worn insulation.

**Ampere rating  (on tool data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.G.)

  25’ 

16 

16 

16 

16 

14 

14

  50’ 

16 

16 

16 

14 

14 

12

  100’ 

16 

16 

14 

12 

10 

**Used on 12 gauge - 20 amp circuit.

NOTE:

 AWG = American Wire Gauge

WARNING:

Keep  the  extension  cord  clear  of  the  working  area.
Position the cord so that it will not get caught on lumber, 
tools or other obstructions while you are working with a 
power tool. Failure to do so can result in serious personal 
injury.

WARNING:

Check  extension  cords  before  each  use.  If  damaged
replace immediately. Never use tool with a damaged cord 
since touching the damaged area could cause electrical 
shock resulting in serious injury.

ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric power 
tools,  which  eliminates  the  need  for  the  usual  three-
wire  grounded  power  cord.  All  exposed  metal  parts  are 
isolated  from  the  internal  metal  motor  components  with 
protecting  insulation.  Double  insulated  tools  do  not  need 
to be grounded.

WARNING:

The  double  insulated  system  is  intended  to  protect 
the user from shock resulting from a break in the tool’s
internal insulation. Observe all normal safety precautions 
to avoid electrical shock.

NOTE:

 Servicing of a tool with double insulation requires 

extreme care and knowledge of the system and should be 
performed only by a qualified service technician. For service, 
we suggest you return the tool to your nearest authorized 
service center for repair. Always use original factory replace-
ment parts when servicing.

ELECTRICAL CONNECTION

This tool has a precision-built electric motor. It should be 
connected to a 

power supply that is 120 volts, 60 Hz, AC 

only (normal household current). 

Do not operate this tool 

on direct current (DC). A substantial voltage drop will cause 
a loss of power and the motor will overheat. If your tool does 
not operate when plugged into an outlet, double-check the 
power supply.

Summary of Contents for RS281VS

Page 1: ...eered and manufactured to Ryobi s high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To red...

Page 2: ...y 9 n Operation 9 13 n Maintenance 14 n Accessories 14 n Parts Ordering Service 16 TABLE OF CONTENTS INTRODUCTION This tool has many features for making its use more pleasant and enjoyable Safety perf...

Page 3: ...tool n Keep the tool and its handle dry clean and free from oil and grease Always use a clean cloth when clean ing Never use brake fluids gasoline petroleum based products or any strong solvents to cl...

Page 4: ...ed should be carefully checked to determine that it will operate properly and perform its intended function Check for alignment of moving parts binding of moving parts breakage of parts mounting and a...

Page 5: ...injury user must read and understand operator s manual before using this product Eye Protection Always wear safety goggles safety glasses with side shields or a full face shield when operating this pr...

Page 6: ...ntially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates a situation that may result in property damage WARNING To avoid se...

Page 7: ...efore each use If damaged replace immediately Never use tool with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury ELECTRICAL DOUBLE INSULATION D...

Page 8: ...th all operating features and safety rules ON OFF SLIDE SWITCH This sander is equipped with a simple slide switch control RANDOM ORBIT The random orbit motion provides overlapping sanding movements by...

Page 9: ...step in achieving a high quality sanded finish Aluminum oxide silicon carbide and other synthetic abrasives are best for power sanding Natural abrasives such as flint and garnet are too soft for use i...

Page 10: ...ign the holes in the conversion pad with the holes in the backing pad NOTE Line up the holes in the conversion pad with the holes in the backing pad in order for the dustless feature to function prope...

Page 11: ...e the speed Turn the dial to a lower setting towards A WARNING Topreventthepossibilityofsandingdustorforeignobjects being thrown into the face or eyes never attempt to use thesanderwithoutthedustbagpr...

Page 12: ...the coatings manufacturers n Unplug the sander n Remove the dust bag assembly from the sander n Remove the dust bag from the frame n Shake out the dust n Replace the dust bag on the frame n Replace t...

Page 13: ...so could result in accidental starting of the sander resulting in possible serious injury Do not press down on the sander The weight of the unit supplies adequate pressure so let the sanding disc and...

Page 14: ...e to damage from various types of commercial solvents and may be damaged by their use Use clean cloths to remove dirt dust oil grease etc WARNING Do not at any time let brake fluids gasoline petroleum...

Page 15: ...15 NOTES...

Page 16: ...or visit Please call 1 800 525 2579 for your nearest Ryobi Authorized Service Center You can also check our web site at www ryobitools com for a complete list of Authorized Service Centers MODEL NO AN...

Reviews: