Page 10 — English
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKERS
The circuit breakers are provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
ANSI/UL-2201 CERTIFIED
This generator complies with the ANSI/UL-2201 Standard
for Low Carbon Monoxide (CO) Emission Rates for portable
generators. When used properly, portable generators with
lowered CO emissions and CO shutoff capability mitigate
the risk of CO related poisoning.
DANGER:
ANSI/UL 2201 compliance is not a substitute for safe
generator practices. Always operate the generator in
open, outdoor areas, at least 20 feet away from occu-
pied structures. Never operate the generator near open
windows, doors, or other unventilated spaces.
AUTOMATIC SHUTOFF
The generator’s carbon monoxide sensor is designed to
monitor the level of carbon monoxide present during genera-
tor operation. If the unit is positioned incorrectly and carbon
monoxide levels rise to an unsafe level, the LED on the sensor
will flash red and the generator will automatically shut down.
Leave the area immediately and relocate to an open outdoor
area. Ventilate the area thoroughly before occupying again.
Ensure the generator is located in an open, outdoor area at
least 20 feet away from all doors, windows, and occupied
spaces, and point exhaust away from occupied structures
before restarting.
NOTE:
After a shutoff event has occured, the LED will con-
tinue to flash red for up to 20 minutes. Once the generator
is relocated and CO levels are safe, the generator can be
restarted even if the light is still flashing.
ENGINE SWITCH/FUEL VALVE/
CHOKE LEVER
The engine switch/fuel valve/choke lever is used when start-
ing, stopping, and running the engine.
FUEL TANK
The fuel tank has a capacity of 4 gallons.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Consult
with a qualified local electrician for grounding requirements
in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and remove
the oil drain plug to allow old engine lubricant to be drained.
RECEPTACLES
Your generator has the following single phase, 60 Hz out-
lets: two 120 Volt AC, 20 Amp duplex receptacles and one
120 Volt AC 30 Amp RV receptacle. These can be used for
operating appropriate appliances, electrical lighting, tools,
and motor loads.
RECOIL STARTER GRIP
The recoil starter grip is used to start the generator’s engine.
FEATURES
PRODUCT SPECIFICATIONS
ENGINE
Engine Type ...................................................... 212cc OHV
Spark Plug .................................NGK BP6ES or equivalent
Engine Lubricant Volume................... approximately 20 oz.
Fuel Volume ................................................................4 gal.
GENERATOR
Rated Voltage .............................................................120 V
Rated Amps ................................................................. 30 A
Rated Output*......................................................... 3600 W
Starting Watts ......................................................... 4500 W
Rated Frequency ....................................................... 60 Hz
*Rated output determined by PGMA Standard G300