7 — English
SYMBOLS
FUEL WARNING
No smoking when filling with gasoline.
Do not overfill. Full level is 1 in. below
the top of the fuel neck. Stop the en-
gine for five minutes before refueling to
avoid the heat from the muffler igniting
fuel vapors.
ENGINE LUBRICANT WARNING
You must add lubricant before first operating the generator. The
oil reservoir capacity is 0.42 qt. Always check the lubricant level
before each operation. The lubricant level should always register
between the hatched areas on the dipstick. The unit is equipped
with a sensor which will automatically shut off the engine if the
lubricant level falls below a safe limit.
GROUNDING WARNING
National Electric Code requires generator to be grounded to an approved earth ground.
HOT SURFACE WARNING
Do not touch the muffler or aluminum
cylinder of the engine. They are very HOT
and will cause severe burns. Don’t put
any flammable or combustible materials
in the direct path of the exhaust.
Product does not include ground rod or copper wire. National Electric Code requires generator to be
properly grounded to an approved earth ground. Call an electrician for local grounding requirements.
Le produit ne comprend pas de piquet de terre ou de fil en cuivre. Le code electrique americain (National
Electric Code) requiert un générateur pour une bonne mise à la terre approuvée. Appeler un électricien
pour connaître les exigences locales de mise à la terre.
El producto no incluye el alambre de cobre ni la barra de conexión a tierra. Los Reglamentos Nacionales
de Electricidad exigen que el generador esté debidamente conectado a una tierra aprobada.
Comuniquese con un electrista para todo lo relacionado con los requistos de conexión a tierra.
WARNING
ADVERTENCIA
AVERTISSEMENT
940513008-02
Risk of Fire. Check for any fuel overflow or leaking. Stop the engine before refueling.
DANGER
PELIGRO
Risque d’incendie. Vérifier l'absence de débordement ou de fuite de carburant.
Arrêter le moteur avant de fair le plein.
Riesgo de incendio. Revise si hay algún derrame o fuga de combustible. Apague el
motor antes de poner combustible.
940974007-03
ELECTRICAL
EXTENSION CORD CABLE SIZE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load.
Inadequate size cables can cause a voltage drop, which can damage the appliance and overheat the cord.
Current in
Amperes
Load in Watts
Maximum Allowable Cord Length
At 120V
At 240V
#8 Wire
#10 Wire
#12 Wire
#14 Wire
#16 Wire
2.5
300
600
1000 ft.
600 ft.
375 ft.
250 ft.
5
600
1200
500 ft.
300 ft.
200 ft.
125 ft.
7.5
900
1800
350 ft.
200 ft.
125 ft.
100 ft.
10
1200
2400
250 ft.
150 ft.
100 ft.
50 ft.
15
1800
3600
150 ft.
100 ft.
65 ft.
20
2400
4800
175 ft.
125 ft.
75 ft.
25
3000
6000
150 ft.
100 ft.
30
3600
7200
125 ft.
65 ft.
40
4800
9600
90 ft.