2 — English
KEEP AT LEAST
20 FT. AWAY
CO Detector
in Living Areas
Only use OUTSIDE and
FAR AWAY from windows,
doors, and vents.
Exhaust (CO)
Direct exhaust AWAY
from all windows, doors,
and vents.
LOCATE GENERATOR AT LEAST 20 FT.* AWAY TO REDUCE THE
RISK OF CARBON MONOXIDE GETTING INSIDE THE HOME
*
Minimum distance as recommended by U.S. Department of Health and Human
Services Centers for Disease Control and Prevention (www.cdc.gov/co). Your specific
home and/or wind conditions may require additional distance.
To register your Ryobi product,
please visit: www.ryobitools.com
WARNING:
GROUNDING THE GENERATOR
If this generator will be used
only
with cord and plug-connected equipment,
National Electric Code does not require that the unit be grounded. However,
other methods of using the generator may require grounding to reduce the
risk of shock or electrocution. Consult a qualified electrician, electrical in-
spector, or local agency having jurisdiction for local codes or ordinances to
find out if grounding is needed in your situation before using the generator.
When grounding is required, the nut and ground terminal on the frame are
used to connect the generator to a suitable ground source. The ground path
should be made with #8 size wire. Connect the terminal of the ground wire
between the lock washer and the nut, and tighten the nut fully. Connect the
other end of the wire securely to a suitable ground source that is in contact
with the soil for a minimum distance of 8 ft.
The National Electric Code contains several practical ways in which to es-
tablish a good ground source. If a steel or iron rod is used, it should be at
least 5/8 in. diameter, and if a nonferrous rod is used, it should be at least
1/2 in. diameter and be listed as material for grounding. If a rock bottom is
encountered before reaching a depth of 8 ft., drive the ground rod in at an
angle of up to 45
°
. If the rock bottom is again encountered, the rod can be
buried in a trench that is at least 30 in. deep. In all cases, the upper end of the grounding rod should either be flush
with (or below) the ground or must be otherwise protected from physical damage.
All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or
be “Double Insulated.”
It is recommended to:
1. Use electrical devices with 3-prong grounded plugs.
2. Use an extension cord intended for outdoor use with a 3-pole receptacle and a 3-prong plug at opposite ends to
ensure continuity of the ground protection from the generator to the appliance.
Check and adhere to all applicable federal, state, and local regulations relating to grounding specifications. Consult a
qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as
to whether the generator is properly grounded.