background image

3 — English

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

SAVE THESE INSTRUCTIONS. 

To reduce the risks of fire 

or explosion, electric shock, and the injury to persons, 
read and understand all instructions included in this 
manual. Be familiar with the controls and the proper 
usage of the equipment.

READ ALL INSTRUCTIONS

 

KNOW YOUR POWER TOOL. 

Read the operator’s 

manual carefully. Learn the machine’s applications and 
limitations as well as the specific potential hazards related 
to this tool.

WARNING: 

To reduce the risk of fire or explosion:

 

Do not spray flammable or combustible materials near 
an open flame or sources of ignition such as cigarettes, 
motors, and electrical equipment.

  For units intended for use with only water-based or 

mineral spirit-type materials with a minimum flash point 
of 60°C (140°F), do not spray or clean with liquids having 
a flash point less than 60°C (140°F).

  Paint or solvent flowing through the equipment is able to 

result in static electricity. Static electricity creates a risk 
of fire or explosion in the presence of paint or solvent 
fumes. All parts of the spray system, including the pump, 
spray gun, and objects in and around the spray area shall 
be properly grounded to protect against static discharge 
and sparks. 

  Verify that all containers and collection systems are 

grounded to prevent static discharge.

  Connect to a grounded outlet and use grounded 

extension cords. Do not use a 3-to-2 adapter.

  Do not use a paint or a solvent containing halogenated 

hydrocarbons. 

  Keep spray area well ventilated. Keep a good supply of 

fresh air moving through the area. Keep pump assembly 
in a well-ventilated area. 

  Do not smoke in the spray area.

  Do not operate light switches, engines, or similar spark-

producing products in the spray area.

  Keep area clean and free of paint or solvent containers, 

rags, and other flammable materials.

  Know the contents of the paints and solvents being 

sprayed. Read all Material Safety Data Sheets (MSDS) and 
container labels provided with the paints and solvents. 
Follow the paint and solvent manufacturer’s safety 
instructions.

  Fire extinguisher equipment shall be present and working.

WARNING: 

To reduce the risk of skin injection:

  Do not aim the nozzle at, or spray any person or animal.

 Keep hands and other body parts away from the 

discharge. For example, do not try to stop leaks with 
any part of the body.

  Always use the spray tip. Do not spray without spray 

tip in place.  

  Only use a spray tip specified by the manufacturer.

  Use caution when cleaning and changing spray tips. 

In the case where the spray tip clogs while spraying, 
follow the manufacturer’s instructions for turning off 
the unit before removing the spray tip to clean.

  Do not leave the unit energized while unattended. When 

the unit is not in use, turn off the unit in accordance 
with the manufacturer’s instructions.

  High pressure spray is able to inject toxins into the 

body and cause serious bodily injury. In the event that 
injection occurs, seek medical attention immediately.

 Check parts for signs of damage. Replace any 

damaged parts.

  This system is capable of producing 2500 psi. Only use 

replacement parts or accessories that are specified 
by the manufacturer and that are rated a minimum of 
2500 psi.

 Know how to stop the unit quickly. Be thoroughly 

familiar with the controls.

  Verify that all connections are secure before operating 

this unit.

  For household use only.

WARNING: 

To reduce the risk of injury:

  Do not operate or spray near children. Keep children 

away from equipment at all times.

  Do not overreach or stand on an unstable support. 

Keep effective footing and balance at all times.

  Stay alert and watch what you are doing.

  Do not operate the unit when fatigued or under the 

influence of drugs or alcohol.

Summary of Contents for SSP0501

Page 1: ...ormidad con nuestras estrictas normas para brindar fiabilidad facilidad de uso y seguridad para el operador Con el debido cuidado le brindar muchos a os de s lido y eficiente funcionamiento ADVERTENCI...

Page 2: ...ries are warranted for two years HOW TO GET SERVICE Just return the power tool properly packaged and postage prepaid to an Authorized Ser vice Center You can obtain the location of the Service Center...

Page 3: ...and free of paint or solvent containers rags and other flammable materials Know the contents of the paints and solvents being sprayed Read all Material Safety Data Sheets MSDS and container labels pr...

Page 4: ...ids gasoline petroleum based products or any solvents to clean tool Do not use tool if switch does not turn it off Have de fective switches replaced by an authorized service center Before cleaning rep...

Page 5: ...tion of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION Safety Alert Indicates a potential personal injury hazard Read The Operator s Manual To...

Page 6: ...cord since touching the damaged area could cause electrical shock resulting in serious injury ELECTRICAL CONNECTION This product is powered by a precision built electric motor It shouldbeconnectedtoa...

Page 7: ...t completely assembled or if any parts appear to be missing or damaged Use of a product that is not properly and completely assembled could result in serious personal injury n Inspect the product care...

Page 8: ...injection do not point sprayer at any part of the body or person In case of skin injection seek medical attention immediately Do not use without spray tip in place OPERATING THE SPRAYER See Figures 5...

Page 9: ...clean with any flammable liquids such as paint stripper paint remover brush cleaner mineral spirits lacquer thinner turpentine acetone gasoline kerosene etc CLEANING THE SPRAYER AFTER USE The solution...

Page 10: ...and filter Remove the installed spray tip by turning it counter clockwise Remove the atomizer valve assembly Remove the locking nut by turning it counterclockwise Slide the pump housing assembly cont...

Page 11: ...material is spitting or glob bing up Paint container volume is getting low Material being sprayed is too thick Suction tube is loose Atomizer valve is clogged or worn out Worn spray tip or piston Mat...

Page 12: ...ment emball en port pay un centre de r parations agr L adresse du centre de r parations agr le plus proche peut tre obtenue en contactant un repr sentant du service apr s vente par courrier l adresse...

Page 13: ...eu de travail propre et exempt de contenants de peinture ou de solvant de chiffons et d autres mat riaux inflammables Bien conna tre le contenu des peintures et des solvants qui sont pulv ris s Lire t...

Page 14: ...r l outil si le commutateur ne permet pas de l arr ter Faire remplacer les commutateurs d fectueux dans un centre de r parations agr Avant de nettoyer r parer ou inspecter couper le moteur et v rifier...

Page 15: ...recte de ces symboles permettra d utiliser le produit plus efficacement et de r duire les risques SYMBOLE NOM D SIGNATION EXPLICATION Symbole d alerte de s curit Indique un risque de blessure potentie...

Page 16: ...on Remplacer imm diatement tout cordon endommag Ne jamais utilise un outil dont le cordon d alimentation est endommag car tout contact avec la partie endommag e pourrait causer un choc lectrique et de...

Page 17: ...st pas compl tement assembl ou si des pi ces semblent manquantes ou endommag es Le fait d utiliser un produit assembl de fa on inad quate ou incompl te peut entra ner des blessures graves n Examiner s...

Page 18: ...ulv risateur vers soi ou vers quiconque En cas d injection cutan e consulter imm diatement un m decin Ne pas utiliser l outil si l embout de pulv risation n est pas en place UTILISATION DU PISTOLET Vo...

Page 19: ...tivesdufabricant pour effectuer un nettoyage appropri Pour nettoyer le pistolet en vue d un entreposage court terme D brancher le pistolet Si ce n est d j fait retirer le r servoir de peinture et vers...

Page 20: ...er de bien nettoyer l int rieur de l ouverture du logement de la pompe de fa on ce qu il ne reste aucune trace de peinture ou de teinture Nettoyer l vent du logement de la pompe l aide d un trombone r...

Page 21: ...iau pulv ris est trop pais Le tube de succion est desserr La valve de pulv risateur est encrass e ou us e L embout de pulv risation ou le piston est us Mat riel d tre pulv ris a t branl e et a les poc...

Page 22: ...12 Fran ais NOTES...

Page 23: ...as por dos a os FORMA DE OBTENER SERVICIO Simplemente env e la herramienta el ctrica debidamente empaquetada y con el flete pagado por anticipado a un centro de servicio autorizado Puede obtener infor...

Page 24: ...es de pintura o solvente trapos y otros materiales inflamables Conozca el contenido de las pinturas y los solventes que se roc an Lea todas las hojas de datos sobre la seguridad de materiales MSDS y l...

Page 25: ...tos a base de petr leo ni solventes para limpiar la herramienta No utilice la herramienta si el interruptor no apaga Lleve todo interruptor defectuoso a un centro de servicio autorizado para que lo re...

Page 26: ...m s segura el producto SYMBOL NAME DESIGNATION EXPLANATION Alerta de seguridad Indica un peligro posible de lesiones personales Lea el manual del operador Para reducir el riesgo de lesiones el usuario...

Page 27: ...impulsada por un motor el ctrico fabricado con precisi n Debe conectarse nicamente a una l nea de voltaje de 120 voltios 60 Hz de corriente alternasolamente corrientenormalparausodom stico No utilice...

Page 28: ...cto si no est totalmente ensamblado o si alguna pieza falta o est da ada Si utiliza un producto que no se encuentra ensamblado de forma correcta y completa puede sufrir lesiones graves n Inspeccione c...

Page 29: ...a persona En el caso de inyecci n en la piel busque atenci n m dica de inmediato No utilice la unidad sin la punta de rociado en su lugar FUNCIONAMIENTO DEL ROCIADOR Vea las figuras 5 a 7 p gina 13 As...

Page 30: ...rucciones del fabricante del material para una limpieza adecuada Para limpiar el rociador a fin de guardarlo durante un breve per odo Desenchufe el rociador Si a n no lo ha hecho retire el contenedor...

Page 31: ...a bomba de tal manera que no queden restos de materiales de pintura o tinte Limpie el orificio de ventilaci n del alojamiento de la bomba con un clip para papel enderezado o un mondadientes Para volve...

Page 32: ...forma globos El volumen del contenedor de pintura est bajando El material que se est rociando es de masiado espeso El tubo de succi n est flojo La v lvula atomizadora est obstruida o desgastada La pun...

Page 33: ...h brosse de nettoyage cepillo para limpiar F Replacement atomizer valve assembly ensemble valve de pulv risateur de remplacement reemplazo del conjunto de la v lvula atomizadora Fig 1 A Grounding pin...

Page 34: ...n estado B Atomizer valve is bad and needs to be replaced La valve de pulv risateur est en mauvais tat et doit tre remplac e La v lvula atomizadora est en mal estado y necesita ser reemplazada A B Fig...

Page 35: ...14 NOTES...

Page 36: ...MPLACEMENT Les pi ces de remplacement peuvent tre achet es en ligne sur le site www ryobitools com ou par t l phone au 1 800 525 2579 Les pi ces de remplacement peuvent tre obtenues un de nos centres...

Reviews: