background image

5

SPECIFIC SAFETY RULES

 

During normal use the tool will recoil immediately after 
driving a fastener. This is a normal function of the tool. 

Do not attempt to prevent the recoil by holding the nailer 
against the work. Restriction to the recoil can result in 
a second fastener being driven from the nailer. Grip the 
handle firmly and let the tool do the work. Failure to heed 
this warning can result in serious personal injury.

 

Do not drive fasteners on top of other fasteners or with 
the tool at an overly steep angle as this may cause 
deflection of fasteners which could cause injury.

 

Do  not  drive  fasteners  close  to  the  edge  of  the 
workpiece as the wood may split, allowing the fas-
tener to be deflected possibly causing injury.

 

AIR SUPPLY AND CONNECTIONS

 

Do  not  use  oxygen,  combustible  gases  or  bottled 

gases as a power source for this tool as tool will ex-
plode, possibly causing injury or death.

 

Do  not  use  with  an  air  compressor  which  can  po-
tentially exceed 200 psi as tool may burst, possibly 
causing injury. 

 

The  connector  on  the  tool  must  not  hold  pressure 
when air supply is disconnected.  

If an incorrect fitting 

is used, the tool can remain charged with air after discon-
necting and thus will be able to drive a fastener even after 
the air line is disconnected, possibly causing injury.

 

Always disconnect air supply:

•  Before making adjustments
•  When servicing the tool
•  When clearing a jam
•  When tool is not in use
•  When moving to a different work area, as accidental 

actuation may occur, possibly causing injury.

LOADING TOOL

 

Do not load the tool with fasteners when any one of 

the operating controls is activated.

When loading tool: 

 

Never place a hand or any part of body in fastener 
discharge area of tool.

 

Never point tool at anyone.

 

Do  not  pull  the  trigger  or  depress  the  workpiece 
contact as accidental actuation may occur, possibly 
causing injury.

SAVE THESE INSTRUCTIONS

 

Refer to them frequently and use them to instruct others 
who may use this tool. If you loan someone this tool, loan 
them these instructions also.

Summary of Contents for YN200BN

Page 1: ... and manufactured to our high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for your purchase ...

Page 2: ...tative at One World Technologies Inc P O Box 1207 Anderson SC 29622 1207 by calling 1 800 525 2579 or by logging on to www ryobitools com When you request warranty service you must also present proof of purchase documentation which includes the date of purchase for example a bill of sale We will repair any faulty workmanship and either repair or replace any defective part at our option We will do ...

Page 3: ...arts Keep fingers away from trigger when not driving fasteners to avoid accidental firing Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations Use safety equipment Always wear eye protection Dust mask nonskid safety shoes hard hat or hearing protection must be used for appropriate conditions Do not use ...

Page 4: ...the air hose attached Do not operate this tool if it does not contain a legible warning label Do not continue to use a tool that leaks air or does not function properly operation Always assume that the tool contains fasteners Do not carry the tool from place to place holding the trigger Accidental discharge could result Always handle the tool with care Respect the tool as a working implement Never...

Page 5: ...with an air compressor which can po tentially exceed 200 psi as tool may burst possibly causing injury The connector on the tool must not hold pressure when air supply is disconnected If an incorrect fitting is used the tool can remain charged with air after discon necting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Always disconnect ai...

Page 6: ...rn their meaning Proper interpretation of these symbols will allow you to operate the tool better and safer Read The Operator s Manual Safety Alert SYMBOL NAME DESIGNATION EXPLANATION To reduce the risk of injury user must read and understand operator s manual before using this product Eye Protection Precautions that involve your safety Hot Surface To reduce the risk of injury or damage avoid cont...

Page 7: ...imum air pressure The maximum allowable pressure of the compressed air as specified by the manufacturer for operating a tool Operating control A control that separately or as part of an actuation system can cause the actuation of a tool Single sequential actuation Anactuationsysteminwhichthereismorethanoneoperating control and the operating controls must be activated in a specific sequence to actu...

Page 8: ...s Fastener Range 5 8 in to 2 in Magazine Capacity 110 nails SIDE loading magazine QUICK CONNECT AIR FITTING DEPTH OF DRIVE ADJUSTMENT ADJUSTABLE EXHAUST trigger workpiece contact jam release Air Consumption 0 05 ft3 cycle at 100 psi Air Inlet 1 4 in NPT Weight 2 9 lbs NO MAR NOSEPIECE reload indicator ...

Page 9: ...nt The tool free depth of drive adjustment lets the operator select precise driving depth of the fastener jam release A tool free jam release is provided for ease in clearing infrequent jams NO mar nosepiece The no mar nosepiece prevents marring and denting when using the tool on softer woods side loading MAGAZINE The side loading magazine allows easy three step loading of fasteners TRIGGER Your b...

Page 10: ...own into your eyes resulting in possible serious injury WARNING Disconnect the tool from the air supply before leaving the work area moving the tool to another location or handing the tool to another person Failure to do so could result in serious personal injury APPLICATIONS You may use this tool for the purposes listed below Finish and Trim interior and exterior Decorative Trim Book Cases Basebo...

Page 11: ... functioning within the proper range of 70 120 psi no MAR NOSEPIECE See Figure 3 The no mar nosepiece attached to the workpiece contact of the tool helps prevent marring and denting when working with softer woods WARNING Disconnect the tool from the air supply before removing or replacing the no mar nosepiece Failure to do so could result in serious personal injury The no mar nosepiece can be remo...

Page 12: ...ssure that will do the job NOTE Air pressure that is higher than 120 psi may damage the tool The tool must have an air fitting that allows all pressure to discharge from the tool when the air hose connector is disconnected WARNING Always use an air fitting that discharges all the compressed air in the tool at the time the air fitting and air hose connector is disconnected Using an air fitting that...

Page 13: ... of the tool pointed away from you insert a strip of nails into the magazine Be sure the nails are pointed downward as shown CORRECT NAIL POSITION Nails should always be inserted with the points down ward fitting into the nail track or as close as possible to the nail track Nail heads must sit either on the top edge of a rib or inside a track between two ribs Nail heads should never lie on top of ...

Page 14: ... tool against the work surface to depress the workpiece contact Pull the trigger to drive a fastener Allow the tool to recoil away from the work surface as the fastener is driven WARNING During normal use the tool will recoil immediately after driving a fastener This is a normal function of the tool Do not attempt to prevent the recoil by holding the nailer against the work Restriction to the reco...

Page 15: ...r the application To determine depth of drive first adjust the air pressure and drive a test nail To achieve the desired depth use the drive depth adjustment on the tool Disconnect the tool from the air supply Turn the depth selector left or right to change the driving depth Reconnect the tool to the air supply Drive a test nail after each adjustment until the desired depth is set WARNING Disconne...

Page 16: ...eep the tool pointed away from you while clearing the jam Disconnect the tool from the air supply Open magazine and remove fasteners from the tool Pull up on the latch and open the jam release Insert a flat blade screwdriver into the driving mechanism and push the driver mechanism back freeing the fastener jam Remove the bent fastener Close the jam release and latch Reconnect the tool to the air s...

Page 17: ...m the effects of dirt and water in the system Restrictedairflowwillpreventthetoolfromreceiving an adequate volume of air even though the pressure reading is high The results will be a slow operation or reduced driving power Before evaluating tool problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors low points containing water and anything e...

Page 18: ...Press the workpiece contact firmly against the workpiece Pull the trigger The tool must operate With the workpiece contact still depressed release the trigger The driver must return to its up position If the tool successfully meets all the requirements in this checklist it is ready for use Load the proper fasteners for the desired application Set the depth of drive according to the Drive Depth Adj...

Page 19: ... Inadequate air supply Inadequate lubrication Worn or damaged O rings or bumper Install Overhaul Kit Verify adequate air supply Lubricate tool Install Overhaul Kit Air leak near the bottom of the tool Worn or damaged O rings or bumper Incorrect fasteners Damaged fasteners Loose magazine Dirty magazine Worn or damaged driver Verify that fasteners are the correct size Replace fasteners Tighten screw...

Page 20: ...arts can also be obtained at one of our Authorized Service Centers How to locate an Authorized Service Center Authorized Service Centers can be located online at www ryobitools com or by calling 1 800 525 2579 How to obtain Customer or Technical Support To obtain Customer or Technical Support please contact us at 1 800 525 2579 ONE WORLD TECHNOLOGIES INC 1428 Pearman Dairy Road Anderson SC 29625 P...

Reviews: