background image

Spiral

®

 SST and STT Prewire Installation Manual

Spiral

®

 SST and STT Prewire Installation Manual  

  1072124-0  

  Rev 03  

  01/22

1

 

Rytec

®

 installation safety information

The meaning of signal words

Summary

 

Technical content produced by Rytec includes safety information which must be read, understood 

and obeyed to reduce the risk of death, personal injury or equipment damage. This information 

is boxed to set it apart from other text. The boxed text identifies the nature of the hazard and 

appropriate steps to avoid it. 

The safety alert symbol identifies a situation that can result in personal injury. The accompanying 

signal word indicates the likelihood and potential severity of the injury. The meaning of the signal 

words is as follows: 

 

WARNING

Warning indicates a hazardous situation that, if not avoided, could 

result in death or serious injury.

 

CAUTION

Caution indicates a hazardous situation that, if not avoided, could result 

in minor or moderate injury.

 Safety icons used in this manual

 

Shock 

hazard

 

Fall 

hazard

 

Crush 

hazard

 

Cut 

hazard

 

Forklift

Installation safety

 

Do not install any Rytec product until

 you have read and understood the safety information and instructions. Make 

sure all applicable regulations are observed and obeyed at all times.

 

Observe these precautions

 while installing the door:

 

Only trained, qualified and authorized individuals are to install the door and the control system.

 

The installation site comprises the physical area required to safely uncrate, stage and install the door.

 

Make sure all personnel at the installation site have been informed of the date, time and location of the installation. 

 

Make sure there is no pedestrian or vehicular traffic within the installation site for the duration of the installation.

 

Make sure you have and use all required Personal Protective Equipment.

 

Make sure you have adequate personnel and equipment to safely perform all lifts.

 

Make sure you have been informed of any hazardous conditions that exist within the installation site.

 

Make sure the installation site is kept clear of obstructions and debris and that the floor is dry.

 

Make sure you are aware of the location of all power lines, piping and HVAC systems within the installation site.

 

Make sure all accessories installed with the door are approved by the manufacturer.

Requirements – Staffing

 

Two installers 

 

A licensed electrician is 

recommended for making 

all electrical connections

 

Electrician’s responsibilities

Refer to the Rytec System 4

®

 Drive & Control 

Installation & Owner’s Manual for a complete list of the 

electrician’s responsibilities.

 

WARNING

Electrical work must meet 
all applicable local, state and 
national codes. 

Failure to wire the door correctly 
can cause shock, burns or death 
to the people who install, use or 
service the door. 
Failure to comply also voids the 
warranty for the door. 

Requirements – Site Conditions

 

Installers must have unrestricted access to the door 

opening at all times during the installation.

 

Make sure there is no pedestrian or vehicular traffic 

within the installation site for the duration of the 

installation.

Requirements – Lifts

 

WARNING

A forklift is mandatory 

for the 

safe and proper installation of 
this door.  

 

Forklift

 that meets the following specifications:

 

Minimum 4,000-pound lift 

capacity 

 

Minimum height ability:

 

door 12” 

 

48”–

 

wide fork

 

Side shift capability 

 

WARNING

Follow all safety instructions 

on all lifts and ladders used for 
this installation.  

 

Scissor lift

 that meets the following specifications:

 

Can hold both installers 

 

Minimum height ability:

 

door height 

 

 

Alternatively, two ladders

 of sufficient height to 

safely access the door head assembly 

 

 

Spiral

®

 SST and STT Prewire Installation Manual

Other icons used in this manual

 

Indicates instructions which, if not followed, 

could result in 

damage to the door

 or  

voiding of the warranty.

 

Indicates best practice.

  

This is how Rytec Technical 
Support does the job. 

Summary of Contents for Spiral SST

Page 1: ... personnel and equipment to safely perform all lifts Make sure you have been informed of any hazardous conditions that exist within the installation site Make sure the installation site is kept clear of obstructions and debris and that the floor is dry Make sure you are aware of the location of all power lines piping and HVAC systems within the installation site Make sure all accessories installed...

Page 2: ...user terminal Primary drive pulley Drive shaft Wire chase Secondary drive pulley Primary drive belt Secondary drive belt Spring straps Spring clamp and bracket CAN bus repeater box Motor Brake release Encoder inside motor Wireless antenna and antenna arm Corner bracket Inside the drive side console Table of Contents Rytec installation safety information 1 Requirements Staffing 1 Electrician s resp...

Page 3: ...embly 201 L SAI Slot2 CAN signal path CAN signal path NEW in 2022 Spirals Smartsurround light curtains and CAN bus cabling Two new features have been added to Spirals in 2022 both of which change the installation process CAN bus cabling The CAN bus system simplifies cabling and minimizes internal field wiring during installation the system works this way CAN bus cabling is a single chain series of...

Page 4: ... number D0091893 01 0 Configuration DOOR MODEL NAME Spiral Full Vision L Door Width Inches 144 094 Door Height Inches 128 346 Production Width in mm 3 660 Production Height in mm 3 260 Door head sizeB Line Voltage 460V motor mount side Right Hand Motor Motor Duty Standard Duty Motor Horsepower 2 0 Number of solid slats 0 Number of vent slats 0 Brake Release Location Release lever on side column Ho...

Page 5: ...d height match the numbers on the object list 3 Calculate the width to center divide the Door Width a by 2 Write this number on the object list Use it when you center the door 4 Find the total width of the door measure the width of the head assembly c in the crate Write this number on the object list 5 Calculate the total height of the door Start with the Door Height b Measure the height of the he...

Page 6: ...ver If the door has a preinstalled flat top hood cover a remove this end panels first If the door has a preinstalled front hood cover b remove this end panels next The end spacer bracket c is removed with the console cover Do this on both sides of the head assembly 2 L and L R doors remove the side console covers NOTE this is called the belt guard cover on the drive side Do this on both sides of t...

Page 7: ...ed nuts Front screws connect to riveted nuts STT S Full vision doors have a spacer at the rear of the head assembly Line up bracket with spacer Solid panel doors have no spacer SST S R If the door has a slanted top hood cover do not reinstall the outer screws and washers until the cover is installed 13mm Cutting pliers Protect your cables Make sure all cables preinstalled in the head assembly are ...

Page 8: ...cables labeled 01 Make sure the cables are disconnected when you remove the cover You will reconnect them later KEEP REUSE number of screws varies based on height of door number of screws varies based on height of door T40 Remove tags from cables 3 Make sure the vertical guide tracks for the door panels are in the fully lowered position 4 Loosen the holders on the vertical guide track If necessary...

Page 9: ...r 0002425475 Status REL MSPT PRT PRC SETC Object list Original Plant 2000 Rytec Corporation Door Width Inches 144 094 Door Height Inches 128 346 Reference line Centerline w w 1 2 a 90º Width to center 1 2 a 144 1 16 123 3 8 Plumb level square how to position the door correctly as you install the side columns Call Rytec technical support at 800 628 1909 immediately and stop the installation if you ...

Page 10: ...h sides of door opening 26 26 26 If measurements are the same the floor is level 27 If measurements are not the same shim the side with the larger number Use the difference for the height of the shim Measurements should match when you measure with the shims in place 3 If the floor is level install the drive side column first If the floor is not level install the side column that is not shimmed fir...

Page 11: ...r on side column Hood style No spiral hood type Number of Springs 4 Spring Tension in 4 724 LH Inner Spring Pack Qty 0 LH Outer Spring Pack Qty 2 RH Outer Spring Pack Qty 2 0 Order type ZP02 RYTEC MTO Order Order number 20000597 MRP controller 500 B5 ZMAT Creation Date 05 31 2019 Production scheduler T7 Tier 7 Order quantity 1 EA Finish 06 05 2019 Start 06 03 2019 Material number 724 Material desc...

Page 12: ... seal 1 Install bolts on both sides of the seal and hand tighten 2 Make sure the back of the seal is flush with the back of the side column and that there is direct contact with the wall If necessary shim the seal where it meets both side columns and at the anchor point so that both conditions are met 3 Make sure the rear seal is level Anchor rear seal to wall at all anchor points 4 10mm Tighten t...

Page 13: ...ure the distances are the same Measure distance from bottom corner of drive side to top corner of non drive side then from bottom corner of non drive side to top corner of drive side b Make sure the distances are the same 3 Tighten all anchors Laser level Use the screws on the track holders as your reference Measuring tape a a b b Anchoring hardware How to install the head assembly 1 Line up the h...

Page 14: ... and nut are not installed Use at least one anchor on each side of the bracket Rear screw connects to flanged nut Front screw connects to riveted nut 2 2 KEEP REUSE T40 b a How to raise the vertical guide tracks into place 1 Make sure that all of the vertical guide track holders are loose enough to allow the track to move freely DO NOT remove any of the holders 2 Make sure the pins at the top of t...

Page 15: ...ction scheduler T7 Tier 7 Order quantity 1 EA Finish 06 05 2019 Start 06 03 2019 Material number 724 Material description SPIRAL STT L Reservation number 0002425475 Status REL MSPT PRT PRC SETC Object list Original Plant 2000 Rytec Corporation DOOR MODEL NAME Spiral Full Vision L Door Width Inches 144 094 Door Height Inches 128 346 Production Width in mm 3 660 Production Height in mm 3 260 Door he...

Page 16: ...the cable tie on the outer spring strap and let it drop 8 Loosen the clamp on the spring strap 9 Position the spring bracket so that the bumpers and locking tab face the side wall 10 Loop the spring strap around the bolt in the spring bracket Thread the strap between two plates of the clamp Hand tighten the clamp nuts DO NOT trim the strap 11 Set the spring tension This is the distance the springs...

Page 17: ... retaining slot c How to install a second assembly in the side column 1 Install the guide tubes into the second bracket Install the second bracket above the first bracket 2 Follow steps 4 15 for installing the springs Make sure the spring bracket bumpers face out toward the first spring assembly 13mm 2 c a b 01260110 01901506 2 SMALL PARTS 10mm How to install the locking collars at the top and bot...

Page 18: ...d to keep the belt tight Cut the two cable ties to release the belt 4 Remove the top nut on the front baseplate mounting post Keep the nut Loosen the top nut on the rear mounting post DO NOT loosen the bottom nuts b a d c Cutting pliers KEEP REUSE 17mm 5 Set the height of the top nut on the rear baseplate mounting post a 1 Slide the rear flange of the baseplate pulley assembly b under the top nut ...

Page 19: ...ttom hood spreader in the small parts box Locate the bottom hood spreader SMALL PARTS 01900820 2 SMALL PARTS 01900820 2 Drive side Corner bracket Corner bracket Wireless antenna arm Non drive side SMALL PARTS 01901508 L and L R doors bottom hood spreader S and S R doors bottom hood spreader 01900820 L and L R doors 4 screws and nuts S and S R doors 8 screws and nuts Spreader brackets Spreader brac...

Page 20: ...rive side console connect the M12 CAN connectors The male M12 for the cable from the CAN port in the side column to the female M12 connector for the cable that crosses the spreader Line up the embossed arrows on the connectors to align the guide notch and contacts correctly The connectors will only fully connect if they are aligned correctly 2 Find the schematics for the door in the red document e...

Page 21: ...10877 2 5 16 Distance between wall mounted SmartSurround and door track should match distance between cover mounted SmartSurround and door track 2 Connect the two cables that connect the wall mounted SmartSurround light curtain to the CAN port Line up the embossed arrows on the connectors to align the guide notch and contacts correctly The connectors will only fully connect if they are aligned cor...

Page 22: ...10765 0 BTA4 unit 1 b 1210766 0 BTA4 frame 1 c 5550351 0A01 Mounting hardware 5 5550057 0Z01 side column d 1210756 0 Mounting hardware 5 5550353 0 wall SMALL PARTS 1210800 2 5 Line up the two bottom tabs on the BTA4 unit with the bottom tabs in the frame a Then snap the two top tabs into place b 6 In the head assembly on the drive side remove the jumper from port 1 on the CAN repeater a and plug i...

Page 23: ... down but it should not require excessive force to reach the fully released position If you feel too much resistance loosen the tension on the cable DO NOT trim the cable until the brake release has been fully tested Make sure the clamp is tight enough to hold when pressure is applied 1 Locate the brake release cable in the console Loosen the retaining nut and slide it down the length of the brake...

Page 24: ... console A B C A B N GND A B C GND GND A B C WARNING WARNING The activation whip and activator box are used to wire optional additional activators for the door If the junction box is not needed tuck it back into the console The high voltage power whip and junction box are required to bring power to the door When the non drive side cover is reinstalled whips may be run through the rear of the cover...

Page 25: ... 3 Install the spacer bracket from the small parts box onto the side console Do this on both sides of the head assembly SMALL PARTS 01900820 Number of screws varies based on height of door Number of screws varies based on height of door Spacer brackets Splice bracket L L R S S R Bottom hood cover panels T40 KEEP REUSE number of torx screws varies based on size of door number of torx screws varies ...

Page 26: ...and L R doors install the end splice bracket Do this on both sides of the head assembly Splice bracket End splice bracket Flashing L L R S S R Top hood cover panels SMALL PARTS 2 01900820 T40 3 L and L R doors install the rest of the splice brackets 4 S and S R doors install the end splice bracket Do this on both sides of the head assembly 5 S and S R doors finish anchoring the wall mount bracket ...

Page 27: ...overlaps the panel to the left T40 T40 SMALL PARTS 4 4 01901508 01900820 13mm 13mm T40 SMALL PARTS 01900820 4 8 Align side flashing with top of hood cover place flashing tight against the cover and anchor in place Do this on both sides of the head assembly 9 Align top flashing with end of side flashing place flashing tight against the cover and anchor in place The two sections of top flashing over...

Page 28: ...right side of display press arrows to change paramter value Parameter name The Controller Display The Controller Controls Parameter number All three digits are hexadecimal Parameter value value being changed change saved RESET Button Press to toggle the flashing cursor between parameters and values Press and hold to save changes to a value UP Arrow Press to increase a value or parameter number Pre...

Page 29: ...L SAI Slot2 PDN UI 000060 201 0948 9147 L SAI Slot2 until the setting is saved 401 L SAI Slot4 PDN UI 000052 1x to show the first set of light curtains 401 0932 9156 L SAI Slot4 Drive side Non drive side Do This Result 8 If the current selection does NOT light the LEDs Re check the light curtains 9 If the current selection DOES light the LEDs 10 The controller moves to parameter L 501 11 Do This R...

Page 30: ...un mode The door may not open or close completely during automatic calibration This is normal When calibration is complete the door will open and close correctly You can manually adjust the close limit after calibration is complete by changing parameter P 275 See page 34 _0 Press Reset Syncron until the Syncron screen displays _0 Hold Reset To Open Pos RY FT 000091 1x to start sequence _0 Hold Res...

Page 31: ...mity sensor 5 Is the door operating correctly Test listen for grinding whining or excessive motor noise Watch for changes in speed or excessive movement of the motor or drum Yes no action is needed No contact Rytec technical support at 800 628 1909 _0 Hold Reset To Open Pos RY FT 000092 fully open and close door five times Laser level Use the hinge screws as the vertical reference How to reverse t...

Page 32: ... Laser level Always adjust the belt to lower the side of the door panel that is higher 17mm 13mm 3 In the head assembly jump the secondary drive belt one notch in the pulley Adjust the belt one tooth at a time then recheck level 4 Level the door panel again If the door panel is not level repeat these steps and retest If the door panel is level reset the tension on the belt 5 To reset the tension o...

Page 33: ...elease lever DO NOT remove the cable The play in the spring allows it to turn with the release lever until it is free of the motor F211 E Stop Ext1 Emergency Stop Door is Stopped F211 E Stop Ext1 Emergency Stop Lever down brake released Lever up brake reset Controller No action is needed Reset the sensor 10mm 2 Remove the four screws and the bottom cover of the motor 3 Check the distance between t...

Page 34: ...rd 5 The Service level password is saved 6 You can now go to parameter 275 Next navigate to parameter P 275 parameter P 221 for doors with photo eyes and change the value Do This Result 1 The default value is 12 default at 2 You can now change the value The UP arrow increases the value and raises the close limit position for the door The Down arrow decreases the value and lowers the close limit fo...

Page 35: ... press either arrow to start cycling 5 Sec Acl 1 Receiver Transmitter a c b d If the red LED is on run a laser level on the vertical guide track to make sure the light curtains are at the same height Adjust if necessary Laser level 4 Test the Advanced3 light curtains by placing your hand flat across any of the light curtains at the top a middle b and bottom c while the door panel closes Make sure ...

Page 36: ...s S S R doors T40 If the door has a preinstalled front hood cover reinstall the front spacer brackets in front of the console covers 3 Notes S and S R doors have both top and bottom front spreaders 4 If necessary use the spray paint to correct blemishes in the door finish 5 Caulk between the door opening and the door 6 Full vision SST doors remove the protective plastic film from both sides of eac...

Reviews: