Auto-off 

It takes about 20 minutes to enter the standby mode even after the input signal is shut-off.  This is a feature,
not a bug, because it prevents unnecessary on and off switches.

Reset the amp 

After triggering the protection circuitry, one can reset the amp by either 1) turn the power switch on the
plate to off position and then back to on position, or 2) unplug the power core and then plug in again.  The
former is recommended.

Support 

Your satisfaction is paramount to us.  Please feel free to ask us questions or give us feedback.

Summary of Contents for Subwoofer Amplifier

Page 1: ... we recommend the special edition amps Technical specs Crossover frequency control Continuously variable for the subwoofer from 40hz to 160hz 2nd order characteristic 12db oct Phase control Continuously adjustable phase lag control on the subwoofer from 0 to 180 degrees Not recommended to use Please use delay time adjustment on the home theater receiver to adjust the phase Power switch Auto ON OFF...

Page 2: ...n the lower bass band They serve three purposes 1 limit the excursion when excessive rumble signal is present in the input with high damping setting 2 reduce room gain if it becomes noticeable with high damping setting and 3 minor boost at the lower end to further extend the bass extension with med and low damping settings 3 is mostly recommended for vented box or large sealed box For small sealed...

Page 3: ...24db 12db Linkwitz Riley That is 24db oct for the sub and 12db oct for the satellite The anticipation is that the 12db oct roll off of the satellite s natural frequency response will make the overall response as 24db 24db an intended setup for Linkwitz Riley filter This immediately rules out vented ported speakers as front satellite speakers because the setup will become 24db 36db Phase alignment ...

Page 4: ...phase alignment between the subwoofer and satellite at the crossover point For comparative purpose Figure 5 8 taken from a Denon AVR 4800 receiver shows the result when crossover control is at different setting 5 3 2 and 1 o clock respectively while phase control is set at 0 or 7 o clock Note that in Figure 18 a dip is about to form at the crossover point Other Recommendations This subwoofer ampli...

Page 5: ... and off switches Reset the amp After triggering the protection circuitry one can reset the amp by either 1 turn the power switch on the plate to off position and then back to on position or 2 unplug the power core and then plug in again The former is recommended Support Your satisfaction is paramount to us Please feel free to ask us questions or give us feedback ...

Reviews: