6K V2.0 12-14-01
167
Select Receiver Activity-Triggered Macros
Select Receiver Post-Activity Timers
Allows the programmer to execute macros based on activity detected
by the receivers.
Receiver Post-Activity Timers delay the macro execution for a
programmable length of time after last activity.
·
Each receiver has its own
Start-of-Activity Macro, Post-Activity Macro,
and
Post- Activity Timer.
·
The
Receiver Post-Activity Timer
starts each time receiver activity ends.
When the timer expires, the macro associated with the receiver is executed.
The timers require two data digits representing the delay.
“00-99” equals
0.0-9.9 minute delay.
·
These macros execute based solely on receiver activity, and act
independently of the transmitter paths that the receivers drive.
·
Be sure to set the corresponding receiver access mode for Receiver 1
Command Form:
Command
Form
Data Digit
Select RX1 Start-of-Activity Macro
(PW) 26 67 (macro name) * not applicable
Select RX1 Post-Activity Macro
(PW) 26 68 (macro name) * not applicable
Select RX2 Start-of-Activity Macro
(PW) 26 69 (macro name) * not applicable
Select RX2 Post-Activity Macro
(PW) 26 70 (macro name) * not applicable
Select RX1 Post-Activity Timer
(PW) 99 00 xx *
xx = duration = 00
–
99 = 0.0
–0.0 minutes
Select RX2 Post-Activity Timer
(PW) 99 01 xx *
xx = duration = 00
–
99 = 0.0
–0.0 minutes
Acknowledgment:
Sends OK
Errors:
Error
Meaning
? err 1
wrong number of digits entered
? err 2
illegal digit entered
Default Condition:
No macros are assigned; Timers are 1.0 minute
Examples:
These macros execute based solely on receiver activity, and act independently
of the transmitter paths that the receivers drive. The setting of the