Set the SE-RDA to STANDBY
With the SE-RDA OFF:
1.
Press and hold RECORD and FUNCTION buttons simultaneously until the LED
lights steady GREEN (about 3 seconds).
2.
Release the buttons. The LED flashes orange.
The SE-RDA is now in STANDBY mode. It is NOT recording.
If recording has not been started within about 10 minutes of setting to STANDBY, the
unit will turn itself OFF automatically. To restart, repeat the turn-on process.
Setting the SE-RDA to STANDBY
Set the SE-RDA to RECORD
With the SE-RDA in STANDBY mode:
1.
Press and hold the RECORD button (for about 3 seconds) until the LED lights
steady red. The SE-RDA is WARMING UP. The SE_RDA is recording but should not
be donned or used during this time.
2.
After about 50 seconds, the LED begins flashing RED. The SE-RDA is RECORDING
and is ready for use.
The SE-RDA can record for at least ten hours with fresh batteries.
Note: Each time recording is started, all previously recorded data in the unit will be
overwritten. Always ensure that any valuable data has been downloaded before starting
recording.
Note: Do not turn off the SE-RDA at any time during the recording process, even while
resting or when the respirator is not being worn. If the unit is inadvertently turned off
during use, download the logged data before restarting recording to prevent it being
overwritten.
Note: The recorded data remains stored in the unit even if the batteries are removed.
Don the respirator and SE-RDA
1.
Hang the respirator around the neck using the neck strap (SR200) or head
harness (SR100).
2.
Attach the SE-RDA unit securely to the body, either:
a.
in a shirt pocket, or
b.
mounted on a waist belt using the SEA mounting bracket (model no. HSE)