background image

SR700 Particle PAPR — How to 

Copyright © 2013 by The S.E.A. Group 

Make sure the SR500, headpiece and filters are 

intact and correctly assembled.  

Switch on the PAPR. 

 

 

Place the entire facepiece or headpiece into the 

test bag and seal off by closing your hand around 

both the bag and the breathing hose. 

IMPORTANT! Do not in any way obstruct, 

squeeze together or bend the breathing hose. 

              

 

With the other hand, hold the flow tube up 

vertically from the bag. 

 

The floating ball in the tube should be on the line 

marked 175 or slightly above it. 

 

175 l/min

 

If the floating ball isn’t on or above the line, 

shake it a few times, and make sure the tube is 

completely vertical. 

 

If it seems impossible to get a successful 

measurement, call your supervisor. Do not use 

the equipment. 

 

Now test the alarm functions of the SR500.  

With the fan unit running, and still sealing off 

around the breathing hose, block the exhaust of 

the test flow tube with your thumb or hand. 

 

 

The following should happen: 

 

The red triangle should flash on the 

display. 

 

A pulsing beep should sound. 

 

 

+rapid continual beep pulses 

Summary of Contents for Sundstrom SR700

Page 1: ...SR700 Particle PAPR How to Copyright 2013 by The S E A Group 1...

Page 2: ...rst charge the battery Plug in the battery charger to a wall socket and to the battery There is an indicator light on the charger Do not unplug the charger until the battery is fully charged and the c...

Page 3: ...down Fit the three tongues in one of the belt attachments into the slots in the fan unit Continue pushing the attachment until it snaps into place Repeat with the other belt attachment on the opposite...

Page 4: ...filter into the filter adapter until it snaps into place Repeat with the other filter adapter NOTE the filters in both filter adapters must be IDENTICAL You must not use different filters or filter c...

Page 5: ...st the display symbols will light up the alarm will sound and the vibrator will buzz twice After the self test the display will show only the small fan symbol indicating that the fan unit is running n...

Page 6: ...he particle filters are clogged the following will happen The red triangle on the display will flash The beeper will sound for 5 seconds every minute or so WHAT TO DO Stop work Do not remove the respi...

Page 7: ...om the bag The floating ball in the tube should be on the line marked 175 or slightly above it 175 l min If the floating ball isn t on or above the line shake it a few times and make sure the tube is...

Page 8: ...aight up your back without kinks or bends If using the SR200 full face mask run the breathing hose around your waist and up along your chest clean the SR700 Particle PAPR For normal cleaning and disin...

Page 9: ...lugs protect the SR700 If there is a risk of liquids or other material entering the interior of the SR700 during cleaning transport or storage sealing plugs are available to eliminate the risk Simply...

Reviews: