background image

 

1. 

Introduction 

 

This manual applies to the below model: 
 

MIO

LED

 

 

 

The UV systems were made by S.I.T.A. s.r.l. 

Warning: This equipment requires regular maintenance to ensure the requirements of the drinking water treated 
and the maintenance of the improvements as stated by the manufacturer. 

These operating instructions contain important information for the operation and maintenance of the equipment. 

Please  ensure  that  these  operating  instructions  are  carefully  read  by  all  relevant  persons  before  putting  into 
operation, to ensure the safe use of the UV system. The operating instructions are an integral part of the equipment 
supply. 

Before putting into operation, all the conditions necessary for safe operation of the equipment must be fulfilled. 

The  installation,  commissioning  and  maintenance  of  the  equipment  should  only  be  carried  out  by  qualified 
personnel. 

The equipment should only be operated by authorized personnel who have been trained accordingly. 

No modifications should be made to the equipment without consulting maker, as this could affect the safe operation 
of the unit. Maker shall not be held responsible for damage resulting from unapproved modifications.  

I

NSTRUCTION

The operating instructions are to be kept where they will be accessible for operating and 
maintenance personnel. 

 

 

2. 

General Principles and Safety Instructions  

Information about UV irradiation: 

MIOLEDhas been planned specially for destroying harmful bacteria and viruses present in your water. 
Their working is based on a physical principle which is a warranty of security: the output of ultra-violet irradiation. 
The UV light given out by special mercury vapours lamps (UV-C rays 

λ

= 254nm) is highly germicidal because it 

interacts with DNA and RNA, at a molecular level. 
The  deep  bio-structural  disorder  caused  by  such  irradiation  interferes  with  the  development  and  the  ability  of 
reproduction of every kind of micro-organism, making it harmless. 
Generally it is better to mount a pre-filter before the UV sterilizer, in this way the impurities of every nature and 
consistence are kept. 
This system comes to be necessary if we want to have a high degree of sterilization, infact the non-filtration and 
removal of suspended particles in the water has, as a consequence, a decrease of the sterilizer's efficiency. 
If the water to be treated contains sulphydric acid or more than 0.3 p.p.m. of iron or filtrable solids, once passed 
through the sterilizer, it  leaves a residual sediment on the quartz sleeve, which, therefore,  must be  periodically 
cleaned (the frequency depends on the quantity and quality of water treated). 

General directions: 

According to the European rules EN 60204-1 (safety of the set-up off the electrical equipment-general rules) the 
low tension electrical instruments (rule 2014/35/CE) must be connected to a current-tap provided with grounding. 

Electrical Safety Instructions: 

The  lightning  flash  and  arrowhead  symbol  is  to  alert  the  user  to  the  presence  of  un-insulated 
"DANGEROUS VOLTAGE” within the enclosure. The equipment may only be opened if main supply 
is isolated. The main supply must not be restored as long as the equipment is open. This applies to 
both the electrical panel and the UV reactor vessel.

 

WARNING

: Working on live equipment is forbidden. 

 

 

 

Summary of Contents for MIOLED

Page 1: ...DISINFECTION SYSTEM EQUIPMENT FOR THE TREATMENT OF DRINKING WATER MIOLED Installation Operation and Maintenance Manual English 07 2021 ...

Page 2: ...ssioning of the system 4 3 1 Installation under the sink 3 8 flexible connections male delivery and female return 5 3 2 Installation in systems with 8 mm pipes 7 4 MIOLED exploded view spare parts 7 5 Technical Datasheet operative conditions 8 6 Maintenance 9 7 Warranty Conditions 10 8 EC Declaration of Conformity 11 ...

Page 3: ...e which is a warranty of security the output of ultra violet irradiation The UV light given out by special mercury vapours lamps UV C rays λ 254nm is highly germicidal because it interacts with DNA and RNA at a molecular level The deep bio structural disorder caused by such irradiation interferes with the development and the ability of reproduction of every kind of micro organism making it harmles...

Page 4: ... do that it is possible to address to specialized centers for the recovery of dangerous materials or to contact directly our technical department INFORMATION TO USERS pursuant to art 14 of the 2012 19 EU DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE The crossed bin symbol on the appliance or on its packaging indicates that ...

Page 5: ...ion of the debacterization systems of the LED series must be carried out by specialized personnel strictly following the instructions stated below The fittings supplied with the MIOLED are suitable for connection under the sink with 3 8 pipes MIOLED includes the following parts 2X 1X 2X 1X 1X 1X ...

Page 6: ...sink 3 8 flexible connections male delivery and female return Warnings Check that MIOLED is disconnected from the mains that the raw water valve is closed and that the tap is open Install MIOLED on the wall with the fisher supplied ...

Page 7: ...le tap Open the inlet water supply and check that there are no water leaks in any part of the system Connect MIOLED to the electricity Check that the sterilized water comes out and the LED is on the STATUS LED window the LED lights up only when water flows Let the disinfected water flow out for at least 10 minutes before using it in order to purge any impurities present in the system NOTE It is re...

Page 8: ...nd OUT of MIOLED respecting the input and output described on the label 4 MIOLED exploded view spare parts Item Code Description 1 LD5 000 LED Disk CABLE 2 LD1QRZ MIOLED WINDOW 3 LD1OR ORING OF SEAL 4 LD1BLST IGNITOR LD1 5 LDA277 3 8 FLOW SWITCH 6 LD1R LED REACTOR ...

Page 9: ...inside Material Stainless steel 304 Protection class IP 54 Replaceable Led Board Yes UV BOX MIOLED MIOLED AL2 coming soon Material Black Polypropylene Dimensions 210 x 105 x 65 215 x 215 x 90 mm Protection class IP54 Ambient temperature range 5 45 C Power supply 180 264 Vac 50 60 Hz on request 115V 50 60 Hz 8 36 Vdc 8 36 Vdc Power supply cable 1 m 1 m Feed plug Schuko standard UK AUS NZ or passing...

Page 10: ...n MIOLED window A clean MIOLED window increases the effectiveness of disinfection The frequency of cleaning depends on the quality of the treated water check annually Procedure for replacing the LED disk 5000 h max 1 Uninstall MIOLED from the mains and from the water mains see assembly procedure 2 Detach MIOLED from the wall and empty it of residual water 3 Open the MIOLED bottom cover 4 Unscrew t...

Page 11: ...eover the product repaired or tampered by non authorized third parties and the product on which an intervention has been made for defect of for convenience tests is excluded from the warranty Repairs are normally carried out in SITA warehouse or in authorized after sales service centres signalled by SITA The warranty does not cover 1 Accidental breakages due to the transport 2 Breakages due to the...

Page 12: ... CEI EN 55022 radio disturbance characteristics Ministerial Decree 25 2012 Technical provisions concerning equipment for the treatment of water intended for human consumption Ministerial Decree 174 2004 materials in contact with drinking water Ministerial Decree 14 June 2017 Implementation of Directive 2015 1787 EU relating to the quality of water intended for human consumption 2014 68 EU Article ...