change to P003, then press to finish.
9.Saving Power Model
No operation for 3 minutes
,
it will change to saving power
Model, and display shows “--”press any button to awake the
scale expect start button.
Ⅷ. Function parameter setting
Press and turn on
,
it shows“P01 XX”
press or to change parameter
,
press to
change value
,
press to confirm.
P01 zero point tracking setting
(
00
~
09
),
00
:
means 0d
,
01 means
:
1d
P02 filter setup
P02 00
,
01,02....09 the greater the number, the more stable
the data
P03 Anti-vibration coefficient setting
P03 00,01,02.....09 the greater the value, the more stable
the data
P04 boot unit setup
P04 00
:
means kg
P04 01
:
means g
P04 02
:
means lb
P04 03
:
means oz
P05 tri-color lamp alarm mode selection
Long press 3s enter setting
P05 00
:
Choose model and alarm value
00 00
:
represents that three color lamp doesn’t alarm
00 10
:
represents the lower limit alarm mode
00 20
:
represents the upper limit alarm mode
00 30
:
represents interval alarm mode
00 40
:
represents outerval alarm mode
Last 0 can be change, meaning as below:
00 10
:
means 0d warning
00 11
:
means 5d warning
00 12
:
means 10d warning
00 13
:
means 15d warning
00 14
:
means 20d warning
8
9