4
I M P O R TA N T I N S TA L L AT I O N I N F O R M AT I O N
O V E R A L L D I M E N S I O N S
1. Ensure that the electrical system for your pool conforms with all requirements of the
National Electrical Code (NEC) and all relevant local codes and ordinances.
2.
This 12VAC Underwater Light must be installed in accordance with the National Electrical
Code by a Certified Electrician or a Qualified Pool Technician. NOTE: No Bonding Terminal is
required on the forming shell since the fixture is an all plastic construction and complies with
NEC article 680 Requirements.
3. Waterproof conduit must be used from the S.R.Smith
kēlo
LED Light to the ‘above ground’
power supply equipment.
4.
For supply connection, use only an isolating low voltage power supply with ungrounded
output, evaluated for swimming pool use.
5.
DO NOT CONNECT THIS 12VAC LIGHT DIRECTLY TO A 120VAC CIRCUIT - LIGHT
WILL BE DAMAGED.
6.
Fit your S.R.Smith
kēlo
LED Light/s as outlined in the following detailed installation
instructions.
7.
Except when the luminaire is installed in an area of the swimming pool that is not used for
swimming and the lens is adequately guarded to keep any person from contacting it, the
luminaire shall be installed in or on a wall of the pool, with the top of the lens opening not
less than 100 mm (4 inches) below the normal water level of the pool.
CONNECT ONLY TO POWER SUPPLY INTENDED FOR USE WITH SUBMERSIBLE
LUMINAIRES
THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS
74.18mm / 2.92”
59.7mm / 2.35”
17mm
0.669”
88.2mm / 3.47”
ELECTRICAL SPECIFICATION
Input Voltage: 12VAC
Color Change (RGB): 7 Watts max.
White Light Only: 5 Watts max.
COLOR CONTROL
Basic 12VAC mode (off/on control toggling)
S.R.Smith poolLUX
TM
ACP* compatible – see
pg 7
for additional information
Summary of Contents for kelo LED light
Page 2: ...2...