background image

2 - LM10 INSTRUCTION MANUAL

Product Description: 

Importer:

 

SR Smith Australia

 

12 Enterprise Street, Richlands QLD 4077 

 www.srsmith.com/au

Dimensions: 

 

Height: 1700 mm

 

Width: 1030 mm

 

Depth: 1430 mm

Weight: 

 

120 Kg

Power Supply: 

 

Hydraulic Drive - Domestic water supply  

 

(with booster pump when required)

Minimum pressure:

  3.5 bars

User Controls: 

 

Up-down controls on deck upright and 

 

platform handrail

Movement: 

 

Manually removable and mobile, collapsible 

 

for storage

Warranty:  

2 Years

Weight limit: 

 160kg 

GENERAL INFORMATION

Summary of Contents for LM10

Page 1: ...LM10 POOL LIFT INSTRUCTION MANUAL...

Page 2: ......

Page 3: ...ONTENTS GENERAL INFORMATION 2 INSTALLATION 3 Installation area 3 Water pressure check 3 Handling 4 Connection 5 Testing 5 OPERATIONAL GUIDELINES 6 Use of the LM10 6 Emergency stop 7 Maintenance 8 Gene...

Page 4: ...t 1700 mm Width 1030 mm Depth 1430 mm Weight 120 Kg Power Supply Hydraulic Drive Domestic water supply with booster pump when required Minimum pressure 3 5 bars User Controls Up down controls on deck...

Page 5: ...on of additional auxiliary lighting if the 200 lux is not reached Verify access in the installation area Access free of any obstacles Sufficient passage for moving and handling of the lift WATER PRESS...

Page 6: ...packed roll the LM10 to the installation area Images 1 and 2 The position of center of gravity is indicated by the red arrow Refer to the installation sheet for the installation of the fixing lugs or...

Page 7: ...ally open the supply valve Image 9 Ensure the water supply operating pressure is above 3 5 bars Check for any leaks in the water supply network TESTING Carry out several ascents and descents using the...

Page 8: ...the platform ensure stability using the railings located on each side of the platform Once the chair is on the movable platform ensure brakes are locked in and the side elastic cords on both sides of...

Page 9: ...rgency stop The user must evacuate from the lift The water supply must be turned off Image 9 Before returning to service Check the lift status Open the emergency stop valve Open the supply valve Test...

Page 10: ...ater pressure Visual check Yearly Leaks Visual check Yearly Replacement If needed MAINTENANCE General maintenance operations Cleaning of the stainless steel parts Once a week S R Smith rejuvenation ki...

Page 11: ...allow use of the lift as a general entry point into the pool for all users Access to the mobile platform is only authorised for one person at a time Maximum operating load is 160kg DAILY SHUTDOWN AND...

Page 12: ...07 3812 2283 srsmith com au...

Reviews: