1. 

Pull 12VAC cable into input power conduit and connect to 

the appropriate power supply.

2.  Pull in fiber optic cable from the water feature and insert port 

tip into the black  compression fitting - tighten until firmly 
held in place.  Do not overtighten as damage to the fiber optic 
cable may result.

S.R.Smith, LLC

P.O. Box 400  |  Canby, OR 97013

P

 503.266.2231   

TF

 800.824.4387

srsmith.com

79-15278-00 REV6/18

Questions? 

Contact One of Our Dedicated Lighting Specialists. 

   

1-800-824-4387

   

x4012  or  x2282

© 2018 S.R.Smith. All rights reserved.  

3. 

In some cases there may 

be excess fiber optic 
cable.  DO NOT CUT 

the cable, instead coil 
the excess in as large of 
a loop as possible and 
place in the open area of 

the enclosure.  DO NOT 
KINK.  If more space is 

required due to lots of 

excess fiber, it may be 

helpful to add a larger 
pull box in between the 
conduit and CLSFJB or 
CLSFJB2 to house the 

excess fiber.  

4.  Snap the fiber optic light source (CLS-2xx) into 

the metal bracket and adjust the position until 
both of the locating tabs on the ends of bracket 
capture the top and bottom of the CLS-2xx 

housing.  Use cable tie (zip-tie) to close and 
tighten the open ends of the mounting bracket.

WARRANTY INFORMATION

For Lighting product warranty information and details, please visit our website: 

www.srsmith.com/warranty

FJB

FJB2

Summary of Contents for Star Series

Page 1: ...structions Read all instructions before attempting to perform installation work Suitable for Wet Locations Suitable for Outdoor Use Type 3R Rainproof Enclosure FOR USE WITH POOL AND SPA PRODUCTS 40054...

Page 2: ...RTANT SAFETY INFORMATION 3 Electrical Ratings 4 Recommended Tools and Supplies 4 INSTALLATION INSTRUCTIONS 5 Enclosure mounting 5 Input Low Voltage Supply Line 7 Fiber Optic Cable Conduit Connection 7...

Page 3: ...r higher than 8 inches above the maximum pool water level whichever provides greatest elevation The unit must be positioned a minimum of 4 feet 1 2 m from the inside wall of the pool unless separated...

Page 4: ...ning the conduit knockouts 2 Application appropriate and approved rain tight or wet location conduit hubs Note Every installation will have at least two multi conduits one or more for low voltage inpu...

Page 5: ...area that meets the following requirements a Must be mounted on a flat vertical surface b Must be a minimum of 4 inches above the ground level pool deck or higher than 8 inches above the maximum pool...

Page 6: ...it will be installed The screw head must be 1 1 8 away from the wall to allow the unit to be mounted correctly 4 Place the mounting tab of the CLSFJB over the 10 screw and let it hang in place Level t...

Page 7: ...input power and fiber optic cables 2 Using a hole saw open the knockouts for the size of the conduit or 1 being installed 3 Attach an approved rain tight or wet location hub to the conduit After the h...

Page 8: ...ases there may be excess fiber optic cable DO NOT CUT the cable instead coil the excess in as large of a loop as possible and place in the open area of the enclosure DO NOT KINK If more space is requi...

Reviews: