background image

Installation suggestions 

Einbauhinweise-DLS-GLS-EN-V1.2.doc

 

Page 3 of 4 

for tunnel metal detectors type DLS / GLS 

 

 

5. Current loops

 

Insulation for cross connections: 

1  2  3

            1  2  3

 

Use plates (1), bushes (2) and washers (3) of suitable 
material (e.g. Teflon, PVC) 

 

 

Insulation for rollers: 

Drive and tensioning 
rollers near the coil must 
be insulated on one side, 
e.g. with a Novotex bush.
 

3

2

1

In case of a chain belt 
drive the drive roller must 
be insulated on both 
sides. 
Use plates (1), bushes 
(2) and washers (3) of 
suitable material (e.g. 
Teflon, PVC) 
 

The detector coil forms together with the belt 
conveyor a functional unit. 
The electromagnetic field generated within 
the aperture of detector head generates a 
high frequency current in the framework of 
the conveyor resp. frame parts. 
Current loops are formed by cross struts and 
rollers that are automatically compensated 
after power on. Fast changements due to 
mechanical movements (vibrations, shocks 
etc) of this currents loops affect the metal 
detector to generate false alarms. 
For proper operation a stable situation has to 
be created; either open or closed current 
loops. Alternating loops affects the metal 
detector even at a distance of several me-
ters.  
It is therefore necessary to weld cross struts 
on both sides or insulate them electrically at 
one side. 
Rollers have be insulated principly at one 
side. 

In case of internal bear-
ings insulation is estab-
lished at one shaft end, 
and on the sprocket side 
by means of an insulation 
disk. 

 

6. Conveyor belt joint 

 

• 

The “good material” must not be anti-static 

• 

The joint of the belt should be carried out 
according to the sketches. 

• 

Please ensure the conveyor belt remains 
free of contamination, especially during in-
stallation and maintenance (see installa-
tion) 

• 

Materials suitable for high temperatures 
may develop high conductivity (e.g. caused 
by carbon) 
Such “belt conductivity” may result in lower 
sensitivity.  
 
 

Finger toothed connection
diagonally (under 80°),
overlapping (preferred)

diagonally over-
lapping (usable)

straight overlapping
(not reommendable)

 

 

Subject to change withou

ce ! 

09-09-17

t

 

noti

S+S Separation and Sorting Technology GmbH 

 Regener Str. 130 

 D-94513 Schönberg 

 Germany 

Tel. +49(0)8554/308-0 

 Fax: +49(0)8554/2606 

 e-mail: info@se-so-tec.com 

 Internet: www.se-so-tec.com 

 

 

Summary of Contents for GLS 350/150 GENIUS+

Page 1: ...nd se rial number when contacting us Please read these instructions and keep the manual safe Please observe and follow the safety notes S S Separation and Sorting Technology GmbH Regener Stra e 130 D...

Page 2: ...GmbH D 94513 Sch nberg Germany Contact S S Separation and Sorting Technology GmbH Regener Stra e 130 D 94513 Sch nberg Germany Tel 49 8554 3080 Fax 49 8554 2606 E mail info se so tec com Internet www...

Page 3: ...intended purpose 10 4 2 Dangers arising from non compliance with safety notes 10 4 3 Safety notes for the operator 10 4 4 Safety notes during operating maintenance and cleaning 10 4 5 Safety informat...

Page 4: ...are parts 17 8 1 Spare parts drawing 17 8 2 Spare parts list 17 9 Shipping preservation waste disposal transport storage 18 9 1 Shipping preservation waste disposal 18 9 2 Transport 19 9 3 Storage 19...

Page 5: ...ies for the inspection of metallic magnetic and nonmagnetic impurities in packed or unpacked goods on a conveying line without interrupting the production flow The GLS series metal detectors can be us...

Page 6: ...umulations of many metal particles in one batch of the product flow with a resulting malfunction of the separating mechanism jamming of products overfilling of eject container etc The distance between...

Page 7: ...netrated within the aperture of the detector head by a high frequency electro magnetic field which is generated by the control unit and the transmitter coil Two identical voltages are induced into the...

Page 8: ...nts 1 2 3 4 1 Mounting elements for installation 2 Coil connection box 3 Connection cable for electronic unit Options 4 Signalling device 2 3 Combination scopes Different Control units can be used to...

Page 9: ...chlorine and similar substances The metal detector must not be exposed to direct sunlight For the ambient temperature range please refer to the techni cal data sheet in the annex 3 4 Noise levels Sou...

Page 10: ...tended purpose and in a perfect function ing condition Particularly the covers of the detector connection boxes must be closed dur ing operation The operating instructions always have to be in a legib...

Page 11: ...horized modification or repair work all the declarations and guarantees given by the manufacturer will become void 4 10 Inadmissible operation For other applications as enumerated in 4 1 the GLS metal...

Page 12: ...the metal free zone are given in the at tached data sheet A nonmetallic slide plastics or wood must be used within the aperture as a belt support The sliding board and also the run back belt undernea...

Page 13: ...jacent lines interferences can occur Therefore you need to reconfirm S S Pay attention to the following order when mounting the GLS to conveying pipe Do not remove the plastic bars or replace them by...

Page 14: ...Y Triax Cable 1 1 Transmitter Receiver Receiver Transmitter 1 2 3 4 5 6 7 8 9 9 9 9 Terminal coil connection box Connector receiver Connector transmitter 1 1 white brown 2 white brown 2 2 x black shie...

Page 15: ...nd fault rectification If you should have any questions or if there should be any malfunctions please contact the manufacturer If you have any questions please state the equipment type and serial numb...

Page 16: ...ctor thoroughly to remove dirt and deposits After cleaning wipe up any remaining drops of water with a dry non fibrous cloth From time to time apply oil to the stainless steel framework eg Nirostol 55...

Page 17: ...2 8 2 Spare parts list Item No Part Drawing no Material Part No Sp Con Article no for DH 350 Z0007315 polyamide 77008033 Sp 84799080 for DH 350 Z0010960 polyamide 77021768 Sp 84799080 1 Mounting ele...

Page 18: ...protected as for export in wooden crates Care must be taken to ensure that the goods inside the packing are protected against corrosion Any parts that will corrode easily must be wrapped in oil paper...

Page 19: ...make sure the unit cannot topple over or slip Damage caused during transportation must always be reported to the manufacturer 9 3 Storage If possible the unit should be stored in a closed room until...

Page 20: ...10 Annex 10 Annex Technical data sheet Installation suggestions for tunnel metal detectors Circuit diagrams wiring diagrams etc Signalling device option operating instructions 20...

Page 21: ...les 50 Outer dimensions S S USA Tucker Operation sensitivities 45 0 48 Data sheet Weight Passing height Number of mounting holes M12 8 0 73 2 0 4 554 VAB046806 034 760 From Fixing width Date The state...

Page 22: ...ature Control enclosure see data sheet installation instructions for tunnel metal detectors DLS GLS Sabrina Bergmann IP 65 Stainless steel 1 4301 AISI 304 glass bead blasted Product characteristics 10...

Page 23: ...are installed on conveyor belts or chutes The metal detectors consist of a control unit and a tunnel coil Normally the control unit is attached to the tunnel coil Optionally the control unit can be d...

Page 24: ...tector because it must be operated with reduced sensitivity Therefore a metal free area must be observed Fixed metal parts should not extend into this area Large moving metal parts must be kept at an...

Page 25: ...eration a stable situation has to be created either open or closed current loops Alternating loops affects the metal detector even at a distance of several me ters It is therefore necessary to weld cr...

Page 26: ...product temperature 80 C Ask for higher temperature ranges The product to be inspected should pass the detector without interruption However the control unit provides an op eration mode for stop and g...

Page 27: ...Cube 20 x 20 x 20 mm made of plexiglass Article no Material Ball mm Usage Example TCBFE Fe 1 3505 6 000 10 000 TCBS2 Stainless steel 1 4301 6 000 10 000 TCBNF Non Fe brass 6 000 Detection coils Belt...

Reviews: