background image

17

ENGLISH

IMPORTANT:

 The manual you are reading contains fundamental information 

regarding the safety measures to be adopted when installing and starting up. 

It is therefore of utmost importance that both the installer and the user read the 

instructions before assembling and starting up.

1. GENERAL SAFETY INSTRUCTIONS

These symbols ( 

  ) represent the possibility of danger as a result of not 

following the corresponding instructions.

DANGER. Electrocution risk.

Non-compliance with this instruction involves a risk of electrocution.

DANGER.

  Non-compliance  with  this  instruction  involves  a  risk  of  danger  to 

people or things.

ATTENTION.

 Non-compliance with this instruction involves a risk of damaging 

the pump or the unit.

2. GENERAL SAFETY RULES

 

GENERAL OBSERVATIONS.

• 

The machines mentioned in this manual are especially designed to carry out the 

pre-filtration and the circulation of water in swimming pools.

• 

They are designed to work with clean water at a temperature that does not exceed 

35ºC. 

• 

Installation should be carried out in accordance with the specific indications for 

each step.

• 

The regulations in force for the prevention of accidents should be heeded.

• 

Any modification that may be made to the pump requires the previous authorisation 

of the manufacturer. The original manufacturer-authorised spares and accessories 

guarantee greater safety. The pump manufacturer is exempt from all responsibility 

for damage caused by the use of unauthorised spares or accessories. 

• 

During operation the electrical parts of the pump are live. Work can only be carried 

out  on  each  machine  or  on  connected-equipment  after  having  disconnected 

them  from  the  electrical  supply  network  and  having  disconnected  the  starting 

mechanisms.

• 

The user must make sure that assembly and maintenance work is carried out by 

qualified and authorised people who have previously carefully read the installation 

and service instructions.

• 

The operating safety of the machine is only guaranteed with the compliance and 

respect for that mentioned in the installation and service instructions.

• 

The  value  limits  stated  in  the  table  of  technical  specifications  must  under  no 

circumstances be exceeded.

• 

In the case of defective operation or breakdown, contact the nearest manufacturerʼs 

agent or the manufacturerʼs Technical Customer Service.

Summary of Contents for SA-033-M

Page 1: ...PUMPS FOR SWIMMING POOLS POMPES AUTOMOR ANTES POUR PISCINES SELBSTANSAUGENDE PUMPEN F R SCHWIMMBECKEN SA MANUAL DE INSTALACI N Y MANTENIMIENTO INSTALLATION AND MAINTENANCE MANUAL MANUEL D INSTALLATION...

Page 2: ......

Page 3: ...aci n Se deben respetar las normas vigentes para la prevenci n de accidentes Cualquier modificaci n que se pretenda efectuar en la bomba requiere la previa autorizaci n del fabricante Los repuestos or...

Page 4: ...l motor y en las partes el ctricas en tensi n En caso de que la utilizaci n prevista no sea la citada pueden ser necesarias adecuaciones y normativas t cnicas suplementarias ADVERTENCIAS SOBRE LA PRIM...

Page 5: ...Las vibraciones de la m quina En caso de anomal a parar inmediatamente la m quina y proceder a su reparaci n Las instrucciones de instalaci n uso y mantenimiento contenidas en este manual a causa de l...

Page 6: ...que la bomba y el tubo est n sometidos a unos esfuerzos externos que a parte de dificultar el montaje podr a llegar a romperlos Fig 2 La tuber a de aspiraci n se instalar con una ligera pendiente hac...

Page 7: ...ible ya que una tuber a m s larga incrementa el tiempo de aspiraci n y las p rdidas de carga de la instalaci n Se procurar que la bomba este a salvo de posibles inundaciones y reciba una ventilaci n d...

Page 8: ...stalaci n con interruptor seg n el esquema de Conexiones a red Para el motor trif sico utilizar necesariamente un guarda motor con protecci n magneto t rmica Con cualquier tipo de bomba es necesario c...

Page 9: ...cos Para la conexi n Red de 3 x 230 V corresponde el protector del mayor valor indicado Para la conexi n Red de 3 x 400 V ser el protector de menor valor Para intervalos de tensi n distintos a 230V en...

Page 10: ...egar a bloquearla 4 Comprobar que la tensi n y la fuerza de la red se corresponden con las determinadas en la placa de caracter sticas de la bomba Colocar la tapa prefiltro y cerrar sin olvidar coloca...

Page 11: ...cnica m s pr ximo Si el amperaje es m s elevado consultar con el fabricante Vaciar la bomba en los casos que tenga que permanecer alg n tiempo sin funcionar principalmente en pa ses fr os donde pueda...

Page 12: ...ieran da ar las partes hidr ulicas de la bomba Los motores que se suministran con el conjunto motor bomba han sido acondicionados para soportar ambientes calurosos y niveles de humedad elevados 7 2 EL...

Page 13: ...280 50 225 200 285 199 168 SA 075 T 490 311 280 50 225 200 285 199 168 SA 100 M 490 311 280 50 225 200 285 199 168 SA 100 T 490 311 280 50 225 200 285 199 168 SA 125 M 490 311 280 50 225 200 285 199 1...

Page 14: ...14...

Page 15: ...1035 14 JUNTA CUERPO BOMBA HD021060 15 SELLO MECANICO 15 HD056005 16 TAPA CUERPO BOMBA 0 33 0 50 CV HD061000 16 TAPA CUERPO BOMBA 0 75 1 1 5 CV MONO TRI HD061005 17 PIE BOMBA HD066000 18 SILENT BLOCK...

Page 16: ...NDELA ONDULADA M35 0 33 0 50 0 75 1 1 5 CV MT096000 31 TAPA MOTOR 0 33 0 50 CV MONO MT016025 31 TAPA MOTOR 0 75 1 1 5 CV MONO TRI MT016040 32 TIRANTE M5x160 0 33 0 50 CV 4 Unid MT101015 32 TIRANTE M5x...

Page 17: ...ecific indications for each step The regulations in force for the prevention of accidents should be heeded Any modification that may be made to the pump requires the previous authorisation of the manu...

Page 18: ...mp is installed should be dry and aired at all times Special attention should be paid to ensure that under no circumstances water gets into the motor and the electric voltage parts Should the envisage...

Page 19: ...ke In case of irregularity stop the machine immediately and proceed with its repair Because of the complexity of cases dealt with the installation use and maintenance instructions in this manual do no...

Page 20: ...connected so as to avoid external pressure being exerted on the pump and the tube Apart from making assembly more difficult this pressure could even break them Fig 2 Suction tube installation is done...

Page 21: ...at the suction tube is as short as possible since a long tube increases suction time and facility load loss It should be ensured that the pump is free from possible flooding and it is given dry ventil...

Page 22: ...n is sufficient as in the Network connection diagram In the three phase motor a motor guard with heat magnetic protection needs to be used A protection differential of 0 003 A is needed for any pump i...

Page 23: ...ork set the protector at the highest indicated value For connection 3 x 400 V Network set the protector at the lowest value For different voltages from 230V between 220and 240 V to 400V between 380 an...

Page 24: ...us blocking it 4 Check that voltage and network power corresponds to those indicated on the pump specification board Put the cover on the pre filter and close it without forgetting to place the joint...

Page 25: ...earest Customer Technical Service If the amp rate is higher consult the manufacturer Empty the pump in cases where it must remain without use for some time mainly in cold countries where there may be...

Page 26: ...lic parts The motors supplied with the motor pump unit have been protected by IP 55 and are prepared to withstand hot atmospheres and high humidity levels The motors are also provided with a heat prot...

Page 27: ...225 200 285 199 168 SA 075 T 490 311 280 50 225 200 285 199 168 SA 100 M 490 311 280 50 225 200 285 199 168 SA 100 T 490 311 280 50 225 200 285 199 168 SA 125 M 490 311 280 50 225 200 285 199 168 SA...

Page 28: ...28...

Page 29: ...JOINT HD021060 15 MECHANICAL SEAL 15 HD056005 16 PUMP BODY LID 0 33 0 50 HP 1 PH HD061000 16 PUMP BODY LID 0 75 HP 1 HP 1 50 HP 1 PH 3 PH HD061005 17 PUMP BASE HD066000 18 SILENT BLOCK 16x45x13 0 33 0...

Page 30: ...0 75 1 1 5 HP MT096000 31 MOTOR COVER 0 33 0 50 HP 1 PH MT016025 31 MOTOR COVER 0 75 1 1 5 HP 1 PH 3 PH MT016040 32 ROD M5x160 0 33 0 50 HP 4 PCS MT101015 32 ROD M5x170 0 75 1 1 50 HP 4 PCS MT101020 3...

Page 31: ...ent tre observ es Toute modification pr tendant tre effectu e dans la pompe demande l autorisation pr alable du fabricant Les pi ces de rechange originales et les accessoires homologu s par le fabrica...

Page 32: ...al o sera install e la pompe soit constamment sec et ventil Il faut tout particuli rement veiller ce que l eau ne puisse jamais p n trer dans le moteur et dans les parties lectriques sous tension Dans...

Page 33: ...per imm diatement la machine et proc der aux travaux de r paration ch ants Les instructions relatives l installation l usage et l entretien de la machine contenues dans le pr sent manuel ne pr tendent...

Page 34: ...iter que la pompe et le tuyau ne soient soumis des efforts externes qui ind pendamment de g ner les op rations de montage pourraient arriver en causer la rupture Fig 2 La tuyauterie d aspiration devra...

Page 35: ...ferait augmenter le temps d aspiration et les pertes de charge de l installation Il faudra faire en sorte que la pompe soit l abri d ventuelles inondations et qu elle re oive une ventilation s che IN...

Page 36: ...au sch ma des Branchements au r seau sera suffisante Pour le moteur triphas l utilisation d un garde moteur dot d une protection magn tothermique est indispensable Quel que soit le type de pompe l in...

Page 37: ...protecteur de valeur plus grand indiqu Pour la connexion Y r seau de 3 x 400v utiliser le protecteur de valeur plus petit Pour intervalles de tension diff rente 230v entre 220v et 240v et 400v entre 3...

Page 38: ...V rifier que la tension et la puissance d livr es par le r seau lectrique correspondent celles d termin es sur la plaque d identification de la pompe Placez et fermez le couvercle sur le pr filtre san...

Page 39: ...d faut veuillez vous adresser au Service d Assistance Technique le plus proche Si l amp rage est plus lev consulter avec le fabricant Vider votre pompe si elle doit rester quelque temps sans fonctionn...

Page 40: ...oc moteur pompe ont t prot g s selon l IP 55 et conditionn s pour supporter des ambiances chaudes et des niveaux d humidit lev s Les moteurs monophas s sont galement dot s d un protecteur thermique de...

Page 41: ...0 50 225 200 285 199 168 SA 075 T 490 311 280 50 225 200 285 199 168 SA 100 M 490 311 280 50 225 200 285 199 168 SA 100 T 490 311 280 50 225 200 285 199 168 SA 125 M 490 311 280 50 225 200 285 199 168...

Page 42: ...42...

Page 43: ...INT CORPS DE POMPE HD021060 15 GARNITURE MEC NIQUE 15 HD056005 16 COUVERCLE CORPS DE POMPE 0 33 0 50 CV MONO HD061000 16 COUVERCLE CORPS DE POMPE 0 75 1 1 5 CV MONO TRI HD061005 17 PIED DE LA POMPE HD...

Page 44: ...ERCLE MOTEUR 0 33 0 50 CV MONO MT016025 31 COUVERCLE MOTEUR 0 75 1 1 5 CV MONO TRI MT016040 32 TIGE M5X160 0 33 0 50 CV 4 PCS MT101015 32 TIGE M5X170 0 75 1 1 5 CV 4 PCS MT101020 33 VENTILATEUR MOTEUR...

Page 45: ...rfolgen Beachten Sie die allgemeinen Unfallverh tungsvorschriften JedebeabsichtigteVer nderunganderPumpebedarfdervorherigenGenehmigung durch den Hersteller Originalersatzteile und vom Hersteller zugel...

Page 46: ...Wasserspiegels darf eine Saugh he von 2 Metern nicht berschritten werden Um die Ansaugzeit m glichst kurz zu halten sollte die Saugleitung nicht zu lang ausgelegt werden Die Pumpe muss in einem trock...

Page 47: ...auftreten schalten Sie die Maschine sofort ab und veranlassen Sie die Reparatur Es ist leider nicht m glich im Rahmen dieser Anleitung zu Installation Betrieb und Wartung alle vorstellbaren Situation...

Page 48: ...Sie unn tige ussere Krafteinwirkungen auf Pumpe und Rohrleitung die nicht nur die Montage erschweren w rden sondern auch zu einem Bruch der Teile f hren k nnten Abb 2 Installieren Sie die Saugleitung...

Page 49: ...ten denn je l nger die Leitung ist umso l nger ist auch die Ansaugzeit und desto geringer ist die Leistung der Anlage Sch tzen Sie die Pumpe vor berschwemmungen und sorgen Sie f r eine trockene Bel ft...

Page 50: ...mpen ist ein Thermo Schutzschalter eingebaut Es gen gt also die Installation mit Schalter wie im Schema Netzanschluss vorgesehen F r den Dreiphasen Motor muss unbedingt ein magnetothermischer Motorsch...

Page 51: ...n der W rmeschutzschalter Tabelle ein F r die Verbindung im Dreieck 3 x 230V Netz gilt der h here der genannten Werte F r ein eine Y Verbindung 3 x 400V Netz gilt entsprechend der niedrigere Wert Bei...

Page 52: ...dringen und m glicherweise die Pumpe verstopfen 4 berpr fen Sie dass die Netzspannung mit der auf dem Typenschild genannten Spannung bereinstimmt Setzen Sie den Deckel auf den Vorfilter und machen Si...

Page 53: ...enn die Amperezahl h her ist setzen Sie sich bitte mit dem Hersteller in Verbindung Wenn die Pumpe eine Zeit lang nicht in Betrieb genommen werden soll entleeren Sie sie bitte vorher Dies ist besonder...

Page 54: ...der Kombination Motor Pumpe geliefert werden sind IP 55 gesch tzt und f r den Betrieb auch in sehr heisser und sehr feuchter Umgebung geeignet Die einphasigen Motoren verf gen auch ber einen W rmesch...

Page 55: ...11 280 50 225 200 285 199 168 SA 075 T 490 311 280 50 225 200 285 199 168 SA 100 M 490 311 280 50 225 200 285 199 168 SA 100 T 490 311 280 50 225 200 285 199 168 SA 125 M 490 311 280 50 225 200 285 19...

Page 56: ...56...

Page 57: ...MPENK RPER HD021060 15 MECHANISCHE DICHTUNG 15 HD056005 16 PUMPENGEH USEDECKEL 0 33 0 50 PS HD061000 16 PUMPENGEH USEDECKEL 0 75 1 1 5 PS HD061005 17 PUMPENFUB HD066000 18 SILENT BLOCK 16x45x13 0 33 0...

Page 58: ...CKEL 0 33 0 50 PS EINPHASIG MT016025 31 MOTORDECKEL 0 75 1 1 5 PS EINPHASIG DREIPHASIG MT016040 32 VERSTREBUNG M5x160 0 33 0 50 PS 4 ST CK MT101015 32 VERSTREBUNG M5x170 0 75 1 1 5 PS 4 ST CK MT101020...

Page 59: ......

Page 60: ......

Reviews: