7. Make sure that the R5 SUPREME CDU slave has a configured IP Address and a
unique LWE Id.
Figure 97
– Slave, Network Configuration
8. The R5 SUPREME CDU slave must now select the master R5 SUPREME CDU in
the
Select CDU Master
view. Select the master and press ―Next‖. The R5
SUPREME CDU slave will now receive GPS data over LWE from the R5 SUPREME
CDU master.
Figure 98
– Select CDU Master
9. The R5 SUPREME CDU master must now also find all slaves on the LWE network
in order to synchronize configuration, waypoints, active route and route lists with
slaves. This is done in the
Redundant Nav Config
view accessed from
Main Menu
Maintenance
Configuration
Interface
Network
Redundant Nav
.
Figure 99
– Master, Redundant Nav Config
Set the parameter ―Redundant Nav‖ to On.
Highlight each slave unit in the list
and press on the ―Select/Deselect‖ button
and make sure that all slaves that should be synchronized with the master
are marked as ―Selected‖ in the list.
Press ―Save‖. Enter the CDU password (default = ―cdupwd‖) when prompted
and press enter on the virtual keyboard to save the redundant settings.