Page # 18
877 1st Ave. N.W. | Sioux Center, IA 51250 | Toll Free: 1.866.722.1488 | siouxautomation.com
OPERATION
REPLACEMENT PARTS
READ complete manual CAREFULLY
BEFORE attempting operation.
877 1st Ave. N.W. | Sioux Center, IA 51250 | Toll Free: 1.866.722.1488 | siouxautomation.com
OPERATION
REPLACEMENT PARTS
READ complete manual CAREFULLY
BEFORE attempting operation.
HYDRAULIC FILTRATION
•
FILTER SHOWN:
FORCE AMERICA
# F3653-10C
BRAND NAME PART NUMBER
SAC
HYD1A9021
FORCE AMERICA
F3653-10C
NAPA
1551
ZINGA
AE10
Auxiliary Circuit Filter
Auxiliary Circuit Filter
Located on the return line on the right hand side of the hydrualic tank is the auxiliary oil filter. The filter is a “spin-on” type
of filter that will need replacement.
Replace this filter element after 50 hours of break-in use and every 500 hours
thereafter.
Once hydraulic oil has circulated through the
manifold valve and the hydraulic cooler, it
exits into a filter assembly located near the
hydraulic tank. This assembly filters all of the
oil supplied in the auxiliary pump circuit. The
filter is a ‘spin-on’ type of filter. The filter is
removed by turning the filter body counter-
clockwise until it is free from the filter hous
-
ing. This filter will require periodic service
and replacement.
Auxiliary Circuit
Filtration
Filter Replacement (Auxiliary Circuit Filter)
1. Make sure that the filter housing and filter are clean and free of any debris and other contaminates.
2. Make sure that the replacement filter is the correct type for the application.
3. Place a large drain pan or pail underneath the filter housing.
4. Using a filter wrench, remove the filter by turning the filter body counterclockwise until it is free from the housing.
5. Allow sufficient time for any oil in the surrounding hoses to drain into the pan or pail. Allow oil to drain out of the
filter itself.
6. Visually inspect the condition of the filter to determine if the hydraulic system is in need of further servicing.
7. Dispose of the used oil in an environmentally safe manner.
8. Apply a thin coat of clean oil to the top gasket of the filter to ensure a smooth and tight seal with the filter housing.
9. Turn the filter body clockwise and
hand tighten
the filter to the filter housing.
10. Top off the hydraulic reservoir with oil if necessary.
11. Follow all instructions as outlined in the operator’s manual and startup the hydraulic system and run. Check for and
repair any leaks that may arise.