INSTALLATION
4
4-7
004AZ011B
4.3.1.2
Ground connection
Connect the parts marked with symbol (417-IEC-5019) in the electronic equipment directly to an effective
earth-ground point.
Only specially trained personnel are authorized to make the connections in the areas specified on the relative
nameplates.
Before tightening the clamp screws provided, remove any paint from the electronic equipment at the points where the
ground conductors are connected. This will improve electrical continuity.
E0006
D0003272_00
DANGER
D0000004_00
Failure to ground the indicated parts may cause serious electronic equipment damage and personal injury.
D0003272_00
DANGER
D0000004_00
Failure to ground the indicated parts may cause serious electronic equipment damage and personal injury.
4.3.1.3
Electric energy connection
Connect the power cable, whose construction and cross section are adequate for the electrical wiring, to the device
marked in the main electrical cabinet (generally speaking the power cables are connected to the master switch in the
main electrical cabinet).
Connect the ground wire to the terminal marked
PE
located inside the electrical cabinet.
D0003275_00
NOTICE
Unless otherwise specified, the connections are to be made by the installation worker appointed by the client.
D0003275_00
NOTICE
Unless otherwise specified, the connections are to be made by the installation worker appointed by the client.
The power and ground cables should have an adequate cross-section and be constructed so that they are
suitable for the specific wiring system. Information about the correct size is given on the installation drawings
provided at the time of electronic equipment purchase.
4.3.1.4
Conditioner connection
When the conditioner is provided, check the electrical hook-up.
Make sure inside temperature is 35 °C.
Make sure condensate water is drained according to the instructions given in the manufacturer’s manual.
Summary of Contents for CVS Series
Page 2: ......
Page 4: ...004AZ011B...
Page 8: ...004AZ011B TABLE OF CONTENTS Page 0 8...
Page 16: ...004AZ011B 1 GENERAL INFORMATION 1 8...
Page 37: ...T6912 SAFETY EQUIPMENT AND PRECAUTIONS 3 3 3 004AZ011B FIGURE 3 1 2 LOCKOUT TAGOUT QS1...
Page 46: ...3 SAFETY EQUIPMENT AND PRECAUTIONS 3 12 004AZ011B...
Page 62: ...7 ADJUSTMENTS 7 4 004AZ011B...
Page 66: ...8 MAINTENANCE 8 4 004AZ011B...