8 - 21
176.12
.A03
Revision 01 Date 14.11.2001
MAINTENANCE
8
FIGURE 8.2.1.4 - TIMING THE 2ND TURNTABLE/QUALITY CONTROL UNIT
8.2.1.4
Timing the 2nd turn-table/quality control unit
- Remove a sensor from the quality control unit (5) and put the tool (13) in its place.
- Place the centering ring (7) in a cavity that holds a cap on the 2nd transfer turntable (4).
- Using the handwheel, run the second turn-table until the space which holds the centering ring is brought to the point
where the caps are passed from the turn-table to the quality control unit.
- The tool (13) must perfectly coincide with the centering ring (7) in the point mentioned above.
If it does not happen:
- loosen the bolts (10) which hold the gear wheel (12) in place;
- turn the quality control unit, until the correct position is reached;
- fully tighten the bolts (10).
4
2nd transfer turntable
5
Quality control unit
7
Centering ring
10 Bolt
12 Gear wheel
13 Tool
T2432
TIMING 8.2.1.4
5
13
7
4
12
10
Summary of Contents for PMV 224
Page 2: ...TABLE OF CONTENTS 176 12 A03 0 2 Revision 01 Date 14 11 2001 ...
Page 4: ...TABLE OF CONTENTS 176 12 A03 0 4 Revision 01 Date 14 11 2001 ...
Page 34: ...2 22 176 12 A03 Revision 01 Date 14 11 2001 2 MAIN FEATURES ...
Page 42: ...3 8 176 12 A03 Revision 01 Date 14 11 2001 SAFETY EQUIPMENT AND PRECAUTIONS 3 ...
Page 64: ...5 4 5 START UP 176 12 A03 Revision 01 Date 14 11 2001 ...
Page 70: ...6 6 176 12 A03 Revision 01 Date 14 11 2001 6 OPERATING INSTRUCTIONS ...
Page 126: ...8 30 176 12 A03 Revision 01 Date 14 11 2001 8 MAINTENANCE ...
Page 128: ...9 2 176 12 A03 Revision 01 Date 14 11 2001 9 DECOMMISSIONING ...