The engine security cut-off switch
(1)
is found next to the
control box and the magnet
(2)
is found on the front edge
of the hopper. The electrical contact is made when the
magnet approaches the sensor. On opening the engine
housing, the engine cuts out and /or the starter motor is
deactivated.
This is indicated by a red LED on the Pilot System
(see
page 53).
There may be no physical
contact between sensor
and magnet. There must
be 0,24 (+/- 0.20) in (6
mm+/-5) play.
Description and manipulation
Chimney safety Tiger ER et DR
The engine security cut-off switch
(1)
is found next to the
control box and the magnet
(2)
is found on the front edge of
the hopper. The electrical contact is made when the magnet
approaches the sensor. On opening the engine housing, the
engine cuts out and /or the starter motor is deactivated.
Motor cover safety Tiger DR
THE SAFETY ACCESS ROTOR (ER and DR) and OPENING MOTOR COVER (DR)